Page 3 - technical data; air conditioning systems
technical data SplitSky Air air conditioning systems RKS-E2V1B
Page 4 - TABLE OF CONTENTS
• Split Sky Air • Outdoor Units 4 • Outdoor Units • R-410A • RKS-E2V1B TABLE OF CONTENTS RKS-E2V1B 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 5 - Features
• Outdoor Units • R-410A • RKS-E2V1B 1 1 • Split Sky Air • Outdoor Units 5 1 Features O u t d o o r U n i S p l i t S k y R K S - E 2 V 1 B R - 4 1 0 a • Outdoor units for pair application • Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed agai...
Page 6 - Specifications
3 1 2 • Split Sky Air • Outdoor Units 6 • Outdoor Units • R-410A • RKS-E2V1B 2 Specifications 2-1 NOMINAL CAPACITY AND NOMINAL INPUT RKS20E2V1B RKS25E2V1B RKS35E2V1B For combination indoor units + outdoor units Indoor Units FTKS20D3VMW FTKS25D3VMW FTKS35D3VMW Cooling capacity Minimum kW 1.2 1.2 1.2 ...
Page 9 - Electrical data
• Outdoor Units • R-410A • RKS-E2V1B 1 3 • Split Sky Air • Outdoor Units 9 3 Electrical data Representative unit combination Power supply Comp. OFM IFM Indoor unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA FTKS20D3VMW/L RKS20E2V1B 50 - 220 50 - 230 50 - 240 Max. 50Hz 264V Min. ...
Page 15 - Capacity tables; Cooling capacity tables
• Outdoor Units • R-410A • RKS-E2V1B 1 4 • Split Sky Air • Outdoor Units 15 4 Capacity tables 4 - 1 Cooling capacity tables FTKS20D3VMW/L+RKS20E2V1B Cooling 220-240V [50Hz] AFR 8.7 BF 0.21 Indoor Outdoor temperature (°CDB) EWB EDB 20 25 30 32 35 40 (°C) (°C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI T...
Page 21 - Dimensional drawing & centre of gravity; Dimensional drawing
• Outdoor Units • R-410A • RKS-E2V1B 1 5 • Split Sky Air • Outdoor Units 21 5 Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing 3D041800H RKS20-35E2V1B unit (mm) Minimum space for air passage Wall height on air outlet side = less than 1200 Drain outlet (I.D. J 15.9 hose for conne...
Page 22 - Centre of gravity
3 1 5 • Split Sky Air • Outdoor Units 22 • Outdoor Units • R-410A • RKS-E2V1B 5 Dimensional drawing & centre of gravity 5 - 2 Centre of gravity 4D044107M RKS20-35E2V1B
Page 23 - Piping diagram
• Outdoor Units • R-410A • RKS-E2V1B 1 6 • Split Sky Air • Outdoor Units 23 6 Piping diagram 3D047317C RKS20E2V1B Outdoor temperature thermistor Heat exchanger Propeller fan Liquid stopvalve Field piping Field piping Gas stopvalve Compressor Refrigerant flow Cooling Discharge pipe thermistor Heat ex...
Page 24 - Wiring diagram
3 1 7 • Split Sky Air • Outdoor Units 24 • Outdoor Units • R-410A • RKS-E2V1B 7 Wiring diagram 7 - 1 Wiring diagram 3D041707H RKS20-35E2V1B R : Protective earth C74,C75C94,C95,C100 : Capacitor DB1,DB2 : Diode bridge FU1,FU2,FU3 : Fuse IC11 : Solid state relay IPM1 : Triac L : Live L1 : Coil L1R : Re...
Page 25 - Sound data; Sound pressure spectrum
• Outdoor Units • R-410A • RKS-E2V1B 1 8 • Split Sky Air • Outdoor Units 25 8 Sound data 8 - 1 Sound pressure spectrum 4D053221B Octave band sound pressure level Octave band center frequency (Hz) RKS20-25E2V1B approximate threshold hearing for continuous noise NOTES 1 Measure in anechoic room 2 Oper...
Page 26 - Operation range
3 1 9 • Split Sky Air • Outdoor Units 26 • Outdoor Units • R-410A • RKS-E2V1B 9 Operation range 4D029297Q RKS20-35E2V1B Outdoor temp. (°CDB) Continuous operation Pull-down period Indoor temp. (°CWB) Notes: The graph is based on the following conditions:1. Equivalent piping length 7.5 m 2. Level diff...