Page 2 - Refrigeration; I n d u s t r i a l C o n d e n s i n g U n i t s; Technical Data
LRYEQ-AY1LCBKQ3AV1 Refrigeration I n d u s t r i a l C o n d e n s i n g U n i t s E E D E N 1 0 - 7 4 2 Technical Data LCBKQ3AV1_EN.pdf 2 7/01/2011 15:28:04
Page 3 - • Hydronic Systems • Conveni-pack; TABLE OF CONTENTS
• Hydronic Systems • Conveni-pack 1 • Conveni-pack • LRYEQ-AY1 - LCBKQ3AV1 TABLE OF CONTENTS LRYEQ-AY1 - LCBKQ3AV1 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Specifications . . . . . . . . . . . . . . . . ....
Page 4 - Features
• Conveni-pack • LRYEQ-AY1 - LCBKQ3AV1 • Hydronic Systems • Conveni-pack 2 1 Features C o n v e n i - p a c k H y d r o n i c S y s L R Y E Q - A Y 1 - • Integrates high and low temperature refrigeration and air conditioning (including heating) into one system • By using heat recovery, optimised con...
Page 5 - Specifications; -1 Technical Specifications
• Hydronic Systems • Conveni-pack 3 • Conveni-pack • LRYEQ-AY1 - LCBKQ3AV1 2 Specifications 2-1 Technical Specifications LRYEQ16AY1 Casing Colour Ivory white (Munsell code: 5Y7.5/1) Dimensions Unit Height mm 1,680 Width mm 1,240 Depth mm 765 Weight Unit kg 370 Heat exchanger Type Cross fin coil Fan ...
Page 6 - -2 Electrical Specifications
• Conveni-pack • LRYEQ-AY1 - LCBKQ3AV1 • Hydronic Systems • Conveni-pack 4 2 Specifications Refrigerant Type R-410A Control Electronic expansion valve Refrigerant oil Type Daphne FVC50K + FVC68D Charged volume l 0.85 \<br /\> 0.5 Piping connections Suction Super heat K 10K or more Safety devic...
Page 7 - Electrical data; Electrical Data; NOTES; Symbols
• Hydronic Systems • Conveni-pack 5 • Conveni-pack • LRYEQ-AY1 - LCBKQ3AV1 3 Electrical data 3 - 1 Electrical Data 3D066973 LRYEQ16AY1 Model name Units Power supply Comp. OFM Minimum Ssc value (kVA) Z Max. ( Ω ) Hz Volts Min. Max. MCA TOCA MFA MSC RLA kW FLA LRYEQ16AY1(E) 50 380 342 456 35.2 48.3 40...
Page 8 - Capacity tables; Cooling Capacity Tables
• Conveni-pack • LRYEQ-AY1 - LCBKQ3AV1 • Hydronic Systems • Conveni-pack 6 4 Capacity tables 4 - 1 Cooling Capacity Tables LRYEQ16AY1 Notes: 1 ` Is specified point. 2 The condition of characteristics of the tableSuction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 10 - Dimensional drawings; Dimensional Drawings
• Conveni-pack • LRYEQ-AY1 - LCBKQ3AV1 • Hydronic Systems • Conveni-pack 8 5 Dimensional drawings 5 - 1 Dimensional Drawings 3D066895A LRYEQ16AY1 (Knock-out hole) (Knock-out hole) 1 Liquid (For air conditioner) J 9.5 Brazed connection 2 Gas (For air conditioner) J 25.4 Brazed connection 3 Gas (For r...
Page 12 - Centre of gravity; Centre of Gravity
• Conveni-pack • LRYEQ-AY1 - LCBKQ3AV1 • Hydronic Systems • Conveni-pack 10 6 Centre of gravity 6 - 1 Centre of Gravity 4D066966 LRYEQ16AY1 Center of foundation bolt hole Center of foundation bolt hole Center of foundation bolt hole /&%.4$9( ' LCBKQ3AV1_EN.pdf 12 7/01/2011 15:28:07
Page 13 - Piping diagram
• Hydronic Systems • Conveni-pack 11 • Conveni-pack • LRYEQ-AY1 - LCBKQ3AV1 7 Piping diagram 7 - 1 Piping diagram LCBKQ3AV1_EN.pdf 13 7/01/2011 15:28:07 LCBKQ3AV1 3D066689B Outdoor unit to gas pipeø 9.5 C1220T Refrigeration to gas pipeø 15.9 C1220T Refrigeration to liquid pipeø 6.4 C1220T Stop valve...
Page 14 - Wiring diagrams; Wiring Diagrams
• Conveni-pack • LRYEQ-AY1 - LCBKQ3AV1 • Hydronic Systems • Conveni-pack 12 8 Wiring diagrams 8 - 1 Wiring Diagrams 3D059983F LRYEQ16AY1 Low noise mode input WHT To in/d unit To out/d unit To multi unit Note) 4 Is connector color for P.C. board Is connector color for component Is discrimination colo...
Page 16 - External connection diagrams; External Connection Diagrams
• Hydronic Systems • Conveni-pack 13 • Conveni-pack • LRYEQ-AY1 - LCBKQ3AV1 9 External connection diagrams 9 - 1 External Connection Diagrams 3D066960 Note 1 All wiring, components and materials to be produced on the site must comply with the applicable local and national codes.2 Use copper conducto...
Page 17 - Sound data; 0 - 1 Sound Pressure Spectrum
• Conveni-pack • LRYEQ-AY1 - LCBKQ3AV1 • Hydronic Systems • Conveni-pack 14 10 Sound data 10 - 1 Sound Pressure Spectrum Octave band sound pressure level dB(0dB=0.0002 μ bar) LRYEQ16AY1 Location of microphone 4D066974 Overall (dB) Scale 50Hz A 62.0 C 71.0 (B,G,N is already rectified) Measuring place...
Page 18 - Installation; 1 - 1 Installation Method
• Hydronic Systems • Conveni-pack 15 • Conveni-pack • LRYEQ-AY1 - LCBKQ3AV1 11 Installation 11 - 1 Installation Method 3D065029A LRYEQ16AY1 For single unit installation <Pattern 1> For installation in rows <Pattern 1> 300 or more 10 or more <Front> 500 or more 10 or more 10 or more...
Page 19 - 1 - 2 Fixation and Foundation of Units
• Conveni-pack • LRYEQ-AY1 - LCBKQ3AV1 • Hydronic Systems • Conveni-pack 16 11 Installation 11 - 2 Fixation and Foundation of Units 3D065348A LRYEQ16AY1 NOTES 1 The proportions of cement: sand: gravel for the concrete shall be 1:2:4, and the reinforcement bars that their diameter are 10mm, (approx. ...
Page 20 - Operation range; 2 - 1 Operation Range
• Hydronic Systems • Conveni-pack 17 • Conveni-pack • LRYEQ-AY1 - LCBKQ3AV1 12 Operation range 12 - 1 Operation Range LRYEQ16AY1 Outdoor temperature (°CDB) Range for continuous operation Range for pull down operation Outdoor temperature (°CWB) Range for continuous operation Indoor temp. (°CWB) Indoo...