Page 2 - Ceiling Mounted Cassette Type
EDUS39-600-F1_a FXFQ-M 1 FXFQ-M Ceiling Mounted Cassette Type (Multi Flow) 1. External Appearance................................................................................... 22. Specifications .............................................................................................. 33. D...
Page 3 - FXFQ-M 2; External Appearance
External Appearance EDUS39-600-F1_a FXFQ-M 2 1. External Appearance FXFQ12~36M
Page 4 - Specifications
EDUS39-600-F1_a Specifications FXFQ-M 3 2. Specifications Ceiling Mounted Cassette Type (Multi-Flow) Notes: 1. Nominal cooling capacities are based on the following conditions: Return air temperature: 80°FDB, 67°FWB Outdoor temperature: 95°FDBEquivalent ref. piping length: 25 ft / 7.5 m (Horizontal)...
Page 5 - FXFQ-M 4
Specifications EDUS39-600-F1_a FXFQ-M 4 Ceiling Mounted Cassette Type (Multi-Flow) Notes: 1. Nominal cooling capacities are based on the following conditions: Return air temperature: 80°FDB, 67°FWB Outdoor temperature: 95°FDBEquivalent ref. piping length: 25 ft / 7.5 m (Horizontal) 2. Nominal heatin...
Page 6 - Dimensions
EDUS39-600-F1_a Dimensions FXFQ-M 5 3. Dimensions FXFQ12MVJUFXFQ18MVJU 3D042631
Page 7 - FXFQ-M 6
Dimensions EDUS39-600-F1_a FXFQ-M 6 FXFQ24MVJU 3D042632
Page 9 - Piping Diagrams; FXFQ-M 8
Piping Diagrams EDUS39-600-F1_a FXFQ-M 8 4. Piping Diagrams R1T : Thermistor for suction air temperatureR2T : Thermistor for liquid line temperatureR3T : Thermistor for gas line temperature Capacity Gas Liquid 12/18 M φ 1/2” (12.7 mm) φ 1/4” (6.4 mm) 24/30/36 M φ 5/8” (15.8 mm) φ 3/8” (9.5 mm) C:4D0...
Page 10 - Wiring Diagrams
EDUS39-600-F1_a Wiring Diagrams FXFQ-M 9 5. Wiring Diagrams FXFQ12M/18M/24M/30M/36MVJU 3D042620B
Page 11 - FXFQ-M 10; Electric Characteristics
Electric Characteristics EDUS39-600-F1_a FXFQ-M 10 6. Electric Characteristics
Page 12 - Capacity Tables; Cooling Capacity
EDUS39-600-F1_a Capacity Tables FXFQ-M 11 7. Capacity Tables 7.1 Cooling Capacity FXFQ-M TC : Total capacity ; kWSHC : Sensible heat capacity ; kW Refer to Outdoor Unit Capacity Tables for the actual performance data of each indoor and outdoor unit combination. Cooling capacity Unit size Outdoor air...
Page 13 - FXFQ-M 12
Capacity Tables EDUS39-600-F1_a FXFQ-M 12 7.2 Heating Capacity FXFQ-M Refer to Outdoor Unit Capacity Tables for the actual performance data of each indoor and outdoor unit combination. Heating Capacity Indoor unit Outdoor Air Temp. Indoor Air Temp. °FDB 62 65 68 70 72 75 TC TC TC TC TC TC °FDB °FWB ...
Page 14 - Air Velocity and Temperature Distributions
EDUS39-600-F1_a Air Velocity and Temperature Distributions FXFQ-M 13 8. Air Velocity and Temperature Distributions FXFQ12M <Cooling mode> FXFQ12M <Heating mode> 3D052941 AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS
Page 15 - FXFQ-M 14
Air Velocity and Temperature Distributions EDUS39-600-F1_a FXFQ-M 14 FXFQ18M <Cooling mode> FXFQ18M <Heating mode> 3D052942 AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS
Page 17 - FXFQ-M 16
Air Velocity and Temperature Distributions EDUS39-600-F1_a FXFQ-M 16 FXFQ30M <Cooling mode> FXFQ30M <Heating mode> 3D052944 AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS AIRFLOW DISTRIBUTIONS TEMPERATURE DISTRIBUTIONS
Page 19 - Sound Levels; FXFQ-M 18; Overall
Sound Levels EDUS39-600-F1_a FXFQ-M 18 9. Sound Levels Overall Octave Band Level 208V~230V Ceiling Mounted Cassette Type (Multi Flow) Notes: Operation noise differs with operation and ambient conditions. dBA Model 208~230V, 60Hz H L FXFQ12MVJU 31 28 FXFQ18MVJU 33 28 FXFQ24MVJU 34 29 FXFQ30MVJU 38 ...
Page 20 - Installation
EDUS39-600-F1_a Installation FXFQ-M 19 10. Installation Center of Gravity (inches) A B FXFQ12, 18, 24MVJU 9-1/8 4-1/2 FXFQ30, 36MVJU 11-3/8 6-3/4 4D042639A
Page 21 - SAFETY CONSIDERATIONS
Installation EDUS39-600-F1_a FXFQ-M 20 1. SAFETY CONSIDERATIONS Read these SAFETY CONSIDERATIONS carefully before installing air conditioning equipment, and be sure to install it correctly. After completing the installation, make sure that the unit operates properly during the start-up operation. In...
Page 23 - BEFORE INSTALLATION
Installation EDUS39-600-F1_a 22 FXFQ-M 2. BEFORE INSTALLATION • When moving the unit while removing it from the pack- ing case, be sure to lift it by the four hanger brackets. Avoid putting any pressure on other parts, especially, the refrigerant piping, drain piping, and other resin parts. • Be sur...
Page 24 - ACCESSORIES; Check the following accessories are included with your unit.; OPTIONAL ACCESSORIES; a. Items to be checked after completion of work; NOTE TO INSTALLER
EDUS39-600-F1_a Installation FXFQ-M 23 2-1 ACCESSORIES Check the following accessories are included with your unit. 2-2 OPTIONAL ACCESSORIES • The optional decoration panel and remote controller are required for this indoor unit. Table 1 Table 2 FOR THE FOLLOWING ITEMS, TAKE SPECIAL CARE DURING CONS...
Page 25 - SELECTING INSTALLATION SITE; (1) Select an installation site where the following conditions; DANGER; • Do not install unit in an area where flammable materials are; WARNING; • If supporting structural members are not strong enough to; NOTE; • Install the indoor and outdoor units, power supply wiring
Installation EDUS39-600-F1_a 24 FXFQ-M 3. SELECTING INSTALLATION SITE Attach an additional insulation pipe cover to the unit body when it is believed that the relative humidity in the ceiling exceeds 80%. Use glass wool, polyethylene foam, or some-thing similar with a minimum 3/8 inch thickness as i...
Page 26 - PREPARATIONS BEFORE INSTALLATION; (1) Relation of ceiling opening to unit and suspension; • Refer to the paper pattern for ceiling opening dimen-
EDUS39-600-F1_a Installation FXFQ-M 25 4. PREPARATIONS BEFORE INSTALLATION (1) Relation of ceiling opening to unit and suspension bolt position Installation is possible when ceiling-opening dimensions are as follows:• (2) Make the ceiling opening needed for installation where applicable. (For exis...
Page 27 - Then, cut the inner insulation of the hole portion.; Refer; INDOOR UNIT INSTALLATION; • Attach the hanger bracket to the suspension bolt. Be; For new ceilings; (1) Refer to the paper pattern for installation 5) for ceiling; • The center of the ceiling opening is indicated on the
Installation EDUS39-600-F1_a 26 FXFQ-M 5. INSTALLATION PROCEDURES FOR FRESH AIR INTAKE DUCT CONNECTION (1) Cut off the knockout hole on the side plate. Then, cut the inner insulation of the hole portion. Refer to Fig. 1 (2) Adhere the insulation to the opening of the unit. Refer to Fig. 2 6. INDOOR ...
Page 28 - For existing ceilings; REFRIGERANT PIPING WORK; GENERAL INSTRUCTIONS
EDUS39-600-F1_a Installation FXFQ-M 27 Ceiling work (2) Adjust the unit to the correct position for installation.(Refer to Section 4. (1) PREPARATIONS BEFORE INSTALLATION , P. 67. (3) Make sure the unit is horizontally level. • The indoor unit is equipped with a built-in drain pump and float switch....
Page 30 - DRAIN PIPING WORK
EDUS39-600-F1_a Installation FXFQ-M 29 9. DRAIN PIPING WORK Install the drain pipe as shown below and take measures against condensation. Improperly installed piping could lead to leaks on furniture and belongings. (1) Install drain piping: • The diameter of the drain pipe should be greater than or ...
Page 31 - ELECTRIC WIRING WORK; 0-1 GENERAL INSTRUCTIONS; WIRING DIAGRAM; 0-2 ELECTRICAL CHARACTERISTICS
Installation EDUS39-600-F1_a 30 FXFQ-M WHEN ELECTRIC WIRING WORK IS NOT FINISHED • Remove the electric parts box lids, connect a power supply and remote controller to the terminals. Refer to HOW TO CONNECT WIRINGS , page 12. Next, press the inspection/test operation button “ ” on the remote controll...
Page 32 - 1-1 HOW TO CONNECT WIRINGS
EDUS39-600-F1_a Installation FXFQ-M 31 11. WIRING EXAMPLE AND HOW TO SET THE REMOTE CONTROLLER 11-1 HOW TO CONNECT WIRINGS 〈 Methods of wiring power supply, units and connecting remote controller wirings 〉 • Power supply wiring: Remove the electric parts box lid (1) and connect wires to the power su...
Page 34 - AND ON/OFF OPERATION; Table 5
EDUS39-600-F1_a Installation FXFQ-M 33 11-4 COMPUTERIZED CONTROL: FORCED OFF AND ON/OFF OPERATION 1. Wire specifications and how to perform wiring • Connect the input from outside to terminals T1 and T2 of the terminal block for remote controller. 2. Actuation • The following table explains FORCED O...
Page 35 - CAUTION FOR SERVICING
Installation EDUS39-600-F1_a FXFQ-M 34 12. FIELD SETTING Make sure the terminal box lids are closed on the indoor and outdoor units.Field setting must be made from the remote controller in accordance with the installation condition. • Setting can be made by changing the MODE NO ., , FIRST CODE NO .,...
Page 36 - Accessories; Standard Accessories
EDUS39-600-F1_a Accessories FXFQ-M 35 11. Accessories Standard Accessories Optional Accessories (For Unit) C : 3D043021 Optional Assessories for Controls can be found in the Controller Manual. No. Type FXFQ12MVJU FXFQ18MVJU FXFQ24MVJU FXFQ30MVJU FXFQ36MVJU Item 1 Decoration Panel BYC125K-W1 2 Filter...
Page 37 - FXFQ-M 36
Page 38 - Slim Ceiling Mounted Duct Type
EDUS 39 - 600 - F2 AMERICAS FXDQ-M Slim Ceiling Mounted Duct Type 1645 Wallace Drive, Suite 110 Carrollton, TX75006 [email protected] www.daikinac.com EDUS39-600-F1_a Printed in U.S.A. 08/2009 AMERICAS Aug. 2009