Daikin FUQ125CVEB- Installation Manual

Daikin FUQ125CVEB

Daikin FUQ125CVEB– Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
Page: / 41

Table of Contents:

  • Page 2 – CONTENTS; WARNING; death or serious injury.; CAUTION
  • Page 3 – English; Where there is machinery which emits electromagnetic waves.
  • Page 4 – BEFORE INSTALLATION
  • Page 5 – -2 OPTIONAL ACCESSORIES; Items to be checked after the installation work is completed
  • Page 6 – Points of the operation explanation; SELECTION OF INSTALLATION LOCATION; WARNING and
  • Page 8 – PREPARATION BEFORE INSTALLATION; Name of air outlet Indication on indoor unit
  • Page 9 – NOTE; The above shown parts are all field supply.; Remove the 4 corner covers.
  • Page 10 – How to block the air outlet for 2-way or 3-way air discharge; bearing at the side of the motor not mounted.
  • Page 11 – Bearing
  • Page 13 – INSTALLATION OF THE INDOOR UNIT; manual attached to the optional parts.; To fix hanger
  • Page 14 – REFRIGERANT PIPING WORK; Use dedicated piping cutters and flaring tools for R410A.; Level must be ensured; Piping part
  • Page 15 – Refrigerant piping can be connected from 3 directions.; The refrigerant is pre-charged in the outdoor unit.; If oil adheres, it may weaken the strength of screwed part.; Example of unfavorable consequences
  • Page 17 – Gas side piping insulating method
  • Page 19 – Shorter side
  • Page 20 – The maximum height of the drain riser is 600mm.
  • Page 21 – Vinyl tape
  • Page 23 – [When the electric wiring work is finished]; ELECTRIC WIRING WORK; -1 GENERAL INSTRUCTIONS; Earth terminal
  • Page 24 – -2 SPECIFICATION FOR FIELD SUPPLIED FUSES AND WIRING
  • Page 25 – controller; allo; < Transmission wiring ·
  • Page 26 – CAUTION FOR WIRING; Do not carry out soldering finish when stranded wiring are used.; CAUTION FOR MENDING THE COVER; Terminal block for remote controller wiring; Insulation sleeve
  • Page 27 – remote controller controls 1 indoor unit (standard system).; • Simultaneous operation system:; Pair type; Power supply; Simultaneous operation system
  • Page 28 – Group control
  • Page 29 – • Control with 2 remote controllers:; To control 1 indoor unit with 2 remote controllers.; < Changeover method from Main to Sub and vice versa >; Remove the control box lid according to the “; -3 WIRING CONNECTION METHOD; Control with 2 remote controllers
  • Page 30 – -5 FOR CENTRALIZED CONTROL; * For simultaneous operation system, be sure to
  • Page 31 – MOUNTING CORNER COVER · SUCTION GRILLE; PREPARATION BEFORE; , hook the strap (a) for preventing the suction grille from falling; For rightward piping outlet
  • Page 32 – 0-1 SETTING OF CEILING HEIGHT; Hook the strap
  • Page 33 – TEM INDIVIDUAL SETTING
  • Page 34 – 0-6 SIMULTANEOUS OPERATION SYSTEM INDIVIDUAL SETTING; Refer to; 0-7 SETTING WHEN AN OPTIONAL ACCESSORY IS ATTACHED
  • Page 35 – 1-1 HOW TO DIAGNOSE FOR; 1-1 HOW TO DIAGNOSE FOR PROBLEMS; Trouble shooting with the remote controller display.; ” and; Once
  • Page 36 – 1-2 MALFUNCTION CODE; AF
  • Page 37 – CC; Humidity sensor abnormal; CJ; EA
  • Page 39 – REMOTE CONTROLLER
  • Page 40 – WIRING DIAGRAM
Loading the manual

MODELS

(4-way Blow Ceiling Suspended type)

FUQ71CVEB
FUQ100CVEB
FUQ125CVEB

INSTALLATION MANUAL

CAREFULLY READ THESE INSTRUCTIONS BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.

LESEN SIE DIESE HINWEISE VOR DER INSTALLATION SORGFÄLTIG DURCH.
BEWAHREN SIE DIESE ANLEITUNG AN EINEM LEICHT ZUGÄNGLICHEN ORT FÜR SPÄ-
TERES NACHSCHLAGEN AUF.

VEUILLEZ LIRE ATTENTIVEMENT CES INSTRUCTIONS AVANT L'INSTALLATION.
CONSERVEZ CE MANUEL EN LIEU SÛR POUR POUVOIR VOUS Y REPORTER
ULTÉRIEUREMENT.

LEA DETENIDAMENTE ESTAS INSTRUCCIONES ANTES DE LA INSTALACIÓN
CONSERVE ESTE MANUAL PARA POSIBLES CONSULTAS FUTURAS.

PRIMA DELL'INSTALLAZIONE, LEGGERE ATTENTAMENTE LE PRESENTI ISTRUZIONI.
CONSERVARE IL PRESENTE MANUALE IN UN LUOGO FACILMENTE ACCESSIBILE PER
RIFERIMENTO FUTURO.

Ä

ΙΑΒΑΣΤΕ

ΠΡΟΣΕΚΤΙΚΑ

ΑΥΤΕΣ

ΤΙΣ

Ο

Ä

ΗΓΙΕΣ

ΠΡΙΝ

ΤΗΝ

ΕΓΚΑΤΑΣΤΑΣΗ

ΦΥΛΑΞΤΕ

ΑΥΤΟ

ΤΟ

ΕΓΧΕΙΡΙ

Ä

ΙΟ

ΣΕ

ΒΟΛΙΚΟ

ΜΕΡΟΣ

ΓΙΑ

ΜΕΛΛΟΝΤΙΚΗ

ΑΝΑΦΟΡΑ

.

LEES DEZE INSTRUCTIES ZOGVULDIG DOOR VOORDAT MET DE INSTALLATIE WORDT
BEGONNEN.
BEWAAR DEZE HANDLEIDING VOOR TOEKOMSTIG GEBRUIK OP EEN GESCHIKTE
PLAATS ONDER HANDBEREIK.

LEIA ATENTAMENTE ESTAS INSTRUÇÕES ANTES DA INSTALAÇÃO.
MANTENHA ESTE MANUAL NUM LOCAL DE FÁCIL ACESSO PARA CONSULTA.

ПЕРЕД

УСТАНОВКОЙ

ВНИМАТЕЛЬНО

ПРОЧИТАЙТЕ

ДАННЫЕ

ИНСТРУКЦИИ

.

ХРАНИТЕ

ДАННОЕ

РУКОВОДСТВО

В

ЛЕГКО

ДОСТУПНОМ

МЕСТЕ

ДЛЯ

ЕГО

ПОСЛЕДУЮЩЕГО

ИСПОЛЬЗОВАНИЯ

.

MONTAJDAN ÖNCE BU YÖNERGELERÝ DÝKKATLÝCE OKUYUN.
DAHA SONRA BAKMAK ÜZERE BU KILAVUZU SAKLAYIN.

English

Deutsch

Français

Español

Italiano

Nederlands

Portugues

Ðóññêèé

ÅëëçíéêÜ

SPLIT SYSTEM

Air Conditioners

00_CV_3P177351-6P.fm Page 1 Sunday, September 30, 2012 4:43 PM

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CONTENTS; WARNING; death or serious injury.; CAUTION

1 English FUQ71CVEBFUQ100CVEBFUQ125CVEB SPLIT SYSTEM Air Conditioners Installation manual CONTENTS 1. SAFETY PRECAUTIONS .................................................................................... 1 2. BEFORE INSTALLATION ........................................................................

Page 3 - English; Where there is machinery which emits electromagnetic waves.

English 2 • Be sure to use only the specified parts and accessories for installation work.Failure to use the specified parts may result in the air conditioner falling down, water leakage, electric shocks, a fire, etc. • Install the air conditioner on a foundation that can withstand its mass.Insuffic...

Page 4 - BEFORE INSTALLATION

3 English 2. BEFORE INSTALLATION When unpacking the indoor unit or moving the unit after unpacked, hold the hangers (4 places) and do not apply force to other parts (particularly refrigerant piping, drain piping and resin parts). • Make sure to check in advance that the refrigerant to be used for in...

Other Daikin Models

All Daikin Other