Daikin FTXS80FVMA- Installation Manual

Daikin FTXS80FVMA

Daikin FTXS80FVMA– Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – Wireless remote controller.; Accessories; Removal method; ; CAUTION; Installation method; How to set the different
  • Page 3 – Indoor Unit Installation Drawings; sensor’s detection area.
  • Page 4 – Installing the mounting plate.; mark the boring points on the wall.; Recommended mounting plate retention spots and dimensions; Boring a wall hole and installing wall embedded pipe.; prevent water leakage.
  • Page 5 – Installing indoor unit.
  • Page 6 – When connecting to an HA system.; , install as described in the installation; from the terminal block.) Doing so may cause electric shock or fire.; WARNING; With a Multi indoor unit
  • Page 7 – Refrigerant Piping Work; pipe bender for bending.; Flaring the pipe end.
  • Page 8 – Trial Operation and Testing; Trial operation and testing.
Loading the manual

• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into WARNING and CAUTION.
Be sure to follow all the precautions below: they are all important for ensuring safety.

WARNING

CAUTION

WARNING

CAUTION

Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.

Failure to follow any of CAUTION may result in grave consequences in some cases.

• The following safety symbols are used throughout this manual:

Be sure to observe this instruction.

Be sure to establish an earth connection.

Never attempt.

• After completing installation, test the unit to check for installation errors. Give the user adequate instructions

concerning the use and cleaning of the unit according to the Operation Manual.

• Installation should be left to the dealer or another professional.

Improper installation may cause water leakage, electrical shock, or fire.

• Install the air conditioner according to the instructions given in this manual.

Incomplete installation may cause water leakage, electrical shock, or fire.

• Be sure to use the supplied or specified installation parts.

Use of other parts may cause the unit to come to lose, water leakage, electrical shock, or fire.

• Install the air conditioner on a solid base that can support the weight of the unit.

An inadequate base or incomplete installation may cause injury in the event the unit falls off the base.

• Electrical work should be carried out in accordance with the installation manual and the national electrical wiring

rules or code of practice.

Insufficient capacity or incomplete electrical work may cause electrical shock or fire.

• Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.

• The installation height from the floor must be over 1.8m.

• Use the specified types of wires for electrical connections between the indoor and outdoor units. When installing

wiring for the outdoor unit, after cutting the wires for each connection point, a length of 3mm or longer is required.

Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal overheating or fire.

• For wiring, use a cable length enough to cover the entire distance with no connection. Do not use an extension cord.

Do not put other loads on the power supply, use a dedicated power circuit.

(Failure to do so may cause abnormal heat, electric shock or fire.)

The power supply wire class for the receptacle for the outdoor unit must be polychlorinated vinyl insulation or higher.

• After all installation is complete, check to make sure that no refrigerant is leaking out.

(The refrigerant produces a toxic gas if exposed to flames.)

• Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.

If the gas leaks and builds up around the unit, it may catch fire.

• Establish drain piping according to the instructions of this manual.

Inadequate piping may cause flooding.

• Tighten the flare nut according to the specified method such as with a torque wrench.

If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.

• Note for installing the outdoor unit. (For heat pump model only.)

In cold area where the outside air temperature keep below or around freezing-point for a few days, the outdoor

unit’s drain may freeze. If so, it is recommended to install an electric heater in order to protect drain from freezing. It is recommended that you contact the after-sales service organization.

• After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force on the electrical covers or panels.

Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire. When electrical appliances are connected in Y formation,
if the power supply is damaged in some way, to avoid danger the power supply must be replaced by the maker or by someone with an equivalent certification.

• When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other than the specified

refrigerant (R410A), such as air.

(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.)

• If any refrigerant has leaked out during the installation work, ventilate the room.

(The refrigerant produces a toxic gas if exposed to flames.)

• Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth.

Incomplete earth may cause electrical shock, or fire. A high surge current from lightning or other sources may cause damage to the air conditioner.

• Be sure to install an earth leakage breaker.

Failure to install an earth leakage breaker may result in electric shocks, or fire.

• During pump-down, stop the compressor before removing the refrigerant piping.

If the compressor is still running and the stop valve is open during

pump-down, air will be sucked in when the refrigerant piping is removed, causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.

• During installation, attach the refrigerant piping securely before running the compressor.

If the compressor is not attached and the stop valve is

open during pump-down, air will be sucked in when the compressor is run, causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.

Safety Precautions

DAIKIN AIR CONDITIONER

3P182980-4D M06B012B

Two-dimensional bar code
is a code for manufacturing.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Wireless remote controller.; Accessories; Removal method; ; CAUTION; Installation method; How to set the different

1. Indoor unit. • The indoor unit should be sited in a place where: 1) the restrictions on installation specified in the indoor unit installation drawings are met,2) both air intake and exhaust have clear paths met,3) the unit is not in the path of direct sunlight,4) the unit is away from the source...

Page 3 - Indoor Unit Installation Drawings; sensor’s detection area.

Indoor Unit Installation Drawings Intelligent-eye Sensor (FTXS, FTKS only) 1) Do not hit or violently push the intelligent-eye sensor. This can lead to damage and malfunction.2) Do not place large objects near the sensor. Also keep heating units or humidifiers outside the sensor’s detection area. CA...

Page 4 - Installing the mounting plate.; mark the boring points on the wall.; Recommended mounting plate retention spots and dimensions; Boring a wall hole and installing wall embedded pipe.; prevent water leakage.

1. Installing the mounting plate. • The mounting plate should be installed on a wall which can support the weight of the indoor unit.1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points on the wall. 2) Secure the mounting plat...