Page 2 - technical data; air conditioning systems
Page 3 - • Split Sky Air • Indoor Units; TABLE OF CONTENTS
• Split Sky Air • Indoor Units 1 • Indoor Units • R-410A • FMCQ-A7VEB TABLE OF CONTENTS FMCQ-A7VEB 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 4 - Features
• Indoor Units • R-410A • FMCQ-A7VEB • Split Sky Air • Indoor Units 2 1 Features In do or U ni t S p l i t S k y FM CQ -A 7V EB R- 41 0A • Modern style decoration panel is available in 2 different variations: white (RAL9010) with grey louvers and full white (RAL9010) including white louvers • 360° a...
Page 5 - Specifications; -1 FOR INDOOR UNITS ONLY
• Split Sky Air • Indoor Units 3 • Indoor Units • R-410A • FMCQ-A7VEB 2 Specifications I n d o o r U n it s S p l i t S FM CQ -A 7V E 2-1 FOR INDOOR UNITS ONLY FMCQ50A7VEB FMCQ60A7VEB FMCQ71A7VEB FMCQ100A7VEB FMCQ125A7VEB Nominal input (Indoor only) Cooling kW 5.0 6.0 7.1 10.0 12.5 Heating kW 5.6 6....
Page 6 - -3 ELECTRICAL SPECIFICATIONS
• Indoor Units • R-410A • FMCQ-A7VEB • Split Sky Air • Indoor Units 4 2 Specifications Standard Accessories Item Operation manual Quantity 1 1 1 1 1 Item Installation manual Quantity 1 1 1 1 1 Item Drain hose Clamp for drain hose Washer for hanging bracket Screws Installation guide Insulation for fi...
Page 7 - Electrical data; NOTES
• Split Sky Air • Indoor Units 5 • Indoor Units • R-410A • FMCQ-A7VEB 3 Electrical data FMCQ-A Units Power supply IFM Input Model Type Hz Voltage range Voltage limits MCA MFA kW FLA Cooling Heating FMCQ50A7VEB VE 50 220-240 Max. 264 Min. 198 0.6 16 0.056 0.5 83 67 FMCQ60A7VEB 0.9 16 0.056 0.7 95 114...
Page 8 - Safety device settings
• Indoor Units • R-410A • FMCQ-A7VEB • Split Sky Air • Indoor Units 6 4 Safety device settings FMCQ-A SAFETY DEVICES 50 60 71 100 125 FMCQ PC board fuse 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A Fan motor thermal fuse °C ... ... ... ... ... Fan motor thermal protector °C OFF: 108 ±5 (ON: 96 ±15 ) OFF:...
Page 10 - Control systems; Remote control dimensions; Receiver installation procedure; Receiver detail; Wireless remote control kit for eacht decoration panel
• Indoor Units • R-410A • FMCQ-A7VEB • Split Sky Air • Indoor Units 8 6 Control systems 3D056851 Remote control dimensions Receiver installation procedure Transmitting part Pipe connection side Drain connection side Receiver Decoration panel Remote control holder installation procedure (installation...
Page 11 - Dimensional drawing & centre of gravity; - 1 Dimensional drawing
• Split Sky Air • Indoor Units 9 • Indoor Units • R-410A • FMCQ-A7VEB 7 Dimensional drawing & centre of gravity 7 - 1 Dimensional drawing 3TW31364-1 FMCQ50-60 View A 710 Suspension position 780 (Suspension position) 860 ∼ 910 (Ceiling opening) Notes: 1. Location of the nameplates: - Unit body: o...
Page 13 - - 2 Centre of gravity
• Split Sky Air • Indoor Units 11 • Indoor Units • R-410A • FMCQ-A7VEB 7 Dimensional drawing & centre of gravity 7 - 2 Centre of gravity FMCQ-A 4TW31369-3 Models A B C D FMCQ50,60 202 60 409 358 FMCQ71,100 246 90 411 411 FMCQ125 288 120 420 420
Page 14 - Piping diagram
• Indoor Units • R-410A • FMCQ-A7VEB • Split Sky Air • Indoor Units 12 8 Piping diagram 3TW31365-1 Heat exchanger Refrigerant flow CoolingHeating Liquid pipe connection port FMCQ-FMDQ Gas pipe connection port Refrigerant pipe connection port diameters Model Gas Liquid FMDQ50 J 12.70 J 6.35 FMDQ60,71...
Page 15 - Wiring diagram
• Split Sky Air • Indoor Units 13 • Indoor Units • R-410A • FMCQ-A7VEB 9 Wiring diagram 9 - 1 Wiring diagram 3TW31056-1 FMCQ-A Indoor unit A1P : Printed circuit board A2P : Printed circuit board C1 : Capacitor F1U : Fuse (T, 5A, 250V) F2U : Field fuse HAP : Light emitting diode (Service monitor-gree...
Page 16 - Sound data; 0 - 1 Sound pressure spectrum
• Indoor Units • R-410A • FMCQ-A7VEB • Split Sky Air • Indoor Units 14 10 Sound data 10 - 1 Sound pressure spectrum FMCQ-A 4TW31367-3 FMCQ-A7VEB 50 60 71 100 125 Max fresh air intake volume (m 3 /min) 3,1 3,5 4,3 Maximum fresh air intake volume table The maximum intake air flow volume is as shown in...
Page 18 - 0 - 2 Sound power spectrum
• Indoor Units • R-410A • FMCQ-A7VEB • Split Sky Air • Indoor Units 16 10 Sound data 10 - 2 Sound power spectrum 4TW31367-1 NOTES 1 Data is valid at free field condition2 Data is valid at nominal operation condition3 db(A)= A-weighted sound operation level. (A-scale according to IEC)4 Reference acou...
Page 20 - Air flow pattern
• Indoor Units • R-410A • FMCQ-A7VEB • Split Sky Air • Indoor Units 18 11 Air flow pattern FMCQ50A 4D057229 4m 3m 2m 1m 0m 1m 2m 3m 4m 2.7m 2m 1m 0m 2.7m 2m 1m 0m Cooling air velocity distribution All round air discharge, air flow direction: horizontal Cooling air temperature distribution All round ...