Page 2 - Cooling Only/Heat Pump; air conditioning systems; technical data
Cooling Only/Heat Pump FCQH-D8VEB air conditioning systems technical data
Page 3 - TABLE OF CONTENTS
• Split Sky Air • Indoor Units 1 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB TABLE OF CONTENTS FCQH-D8VEB 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Specifications . . . . . . . . . . . . . . . . ....
Page 4 - Features
• Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB • Split Sky Air • Indoor Units 2 1 Features I n d o o r U n i t S p l i t S k y F C Q H - D 8 V E B C o o l i n g O n l • High COP round flow cassette: up to class A energy labels (Preliminary) • 360° air discharge ensures uniform air flow and tem...
Page 5 - Specifications; -1 Technical Specifications
• Split Sky Air • Indoor Units 3 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB 2 Specifications 2-1 Technical Specifications FCQH71D8VEB FCQH100D8VEB FCQH125D8VEB FCQH140D8VEB Casing Material Galvanised steel plate Dimensions Packing Height mm 262 304 304 304 Width mm 882 Depth mm 882 Unit He...
Page 6 - -2 Electrical Specifications
• Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB • Split Sky Air • Indoor Units 4 2 Specifications 3 Safety device settings Safety devices Item Installation and operation manual Drain hose Clamp for drain hose Washer for hanger bracket Screws Installation guide Insulation for fitting Sealing pad...
Page 7 - Options
• Split Sky Air • Indoor Units 5 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB 4 Options )&4+'9(% 3TW 2 3 2 59-1 127(6 ,QVWDOODWLRQER[LVQHFHVVDU\IRUWKHVHDGDSWHUV $OORSWLRQVDUHVXSSOLHGDVNLW 7KH%<&4&::ZKLWHLQVXODWLRQV %HLQIRUPHGWKDWIRUPDWLRQRIGLUWRQZKLWHLQVXODWLRQVLVYLVLEO\VWURQJ...
Page 8 - Dimensional drawing & centre of gravity; Dimensional drawing with standard panel
• Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB • Split Sky Air • Indoor Units 6 5 Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing with standard panel FCQH71D8 3TW 2 8894-1C Nr Name Descri p tion 1 Li q uid p i p e connection ø 9 .5 2 flare connection 2 G as p i p e connec...
Page 9 - Dimensional drawing with auto cleaning panel
• Split Sky Air • Indoor Units 7 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB 5 Dimensional drawing & centre of gravity 5 - 2 Dimensional drawing with auto cleaning panel FCQH71D8VEB 3TW32524-1 NOTES Location of the name p lates: Unit body: on the control box.Decoration p anel: on the p ...
Page 10 - Dimensional drawing with accessoires
• Split Sky Air • Indoor Units 8 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB 5 Dimensional drawing & centre of gravity 5 - 3 Dimensional drawing with accessoires FCQH71D8 3D057034 A Nr Name Descri p tion 1 Indoor unit 2 Decoration p anel 3 Suction chamber 4 C onnecting chamber (Right) 5...
Page 11 - Dimensional Drawing; ireless remote control kit for each decoration
• Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB • Split Sky Air • Indoor Units 9 5 Dimensional drawing & centre of gravity 5 - 4 Dimensional Drawing FCQH71-140D8 3D05 6 851 Transmitting p art Remote control dimensions P i p e connection side Drain connection side Recei v er installation p r...
Page 12 - Centre of gravity
• Split Sky Air • Indoor Units 10 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB 5 Dimensional drawing & centre of gravity 5 - 5 Centre of gravity FCQH71-140D8 4TW 2 8839- 2 Models A B C D F C QH71 2 46 9 0 411 411 F C QH100 ~ 140 2 88 1 2 0 4 2 0 4 2 0
Page 13 - Piping diagram
• Split Sky Air • Indoor Units 11 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB 6 Piping diagram FCQH71-140D8 3TW 2 89 2 5-1 A Coolin g He a tin g Li q uid pipe connection port G a s pipe connection port He a t exch a n g er F a n Model G as Li q uid F C QH71 Ø15. 9 0 Ø 9 .5 2 F C QH100 F C Q...
Page 14 - Wiring diagram
• Split Sky Air • Indoor Units 12 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB 7 Wiring diagram 7 - 1 Wiring diagram FCQH71-140D8VEB 3TW32426-1 NOTES In case of using a central remote control, connect it to the unit in accordance with th attached installation manual. X 2 4A, X33A and X335A a...
Page 15 - Sound data; Sound pressure spectrum
• Split Sky Air • Indoor Units 13 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB 8 Sound data 8 - 1 Sound pressure spectrum FCQH71D8 3TW31757-3 NOTES 1 Hi g h-t a p Lo w -t a p 2 D a t a is v a lid a t f ree f ield condition 3 D a t a is v a lid a t no m in a l oper a tion condition 4 dB A = A...
Page 16 - Sound power spectrum
• Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB • Split Sky Air • Indoor Units 14 8 Sound data 8 - 2 Sound power spectrum FCQH71D8 3TW31757-1 NOTES 1 Hi g h-t a p 2 dB A = A - w ei g hted sound po w er level. ( A -sc a le a ccordin g to IEC) 3 Re f erence a coustic intensity 0dB = 10E- 6 μW/ m ...
Page 17 - Air flow pattern
• Split Sky Air • Indoor Units 15 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB 9 Air flow pattern FCQH71D8 4D057 2 13 Coolin g a ir te m per a ture distribution A ll round a ir disch a r g e, a ir f lo w direction: hori z ont a l Coolin g a ir velocity distribution A ll round a ir disch a r ...