Daikin EWWP065KBW1N- User Manual
Daikin EWWP065KBW1N– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Cooling only; Air cooled mini chiller inverter
- Page 3 – Heating
- Page 5 – Air cooled chiller with centrifugal fan
- Page 6 – Air cooled chiller
- Page 8 – Air cooled chiller, multiple scroll
- Page 10 – Heating only; Water cooled chiller
- Page 13 – Water cooled condenserless chiller
230
230
Air cooled mini chiller inverter
›
Inverter technology ensures: continuous match of requested load ;
excellent part load efficiency (ESEER up to 4.57) ; significant reduction of
starting currents ; precise temperature control (evaporator leaving water)
›
Low operating sound level
›
Easy ‘plug and play’ installation
›
Daikin swing (sizes 005-006-007) or scroll compressor (sizes 009-010-011)
›
Integrated hydronics
›
Available options: evaporator heater type (OP10)
; high ESP pump up to 90 kPa (OPHP)
›
Single phase power supply and main switch included
›
Wide operating range
Cooling only
Capacity class
005
006
007
009
010
011
Cooling capacity
Nom.
kW
Power input
Cooling
Nom.
kW
EER
ESEER
Dimensions
Unit
HeightxWidthxDepth
mm
Weight
Unit
kg
Water heat
exchanger
Type
Brazed plate
Water volume
l
Nominal water
flow
Cooling
l/min
Air heat exchanger Type
Tube type
Hi-XSS
Pump
Nominal ESP unit Cooling
kPa
Hydraulic components Expansion vessel Volume
l
Fan
Air flow rate
Cooling Nom.
m³/min
Fan motor
Speed
Cooling Nom.
rpm
Steps
Sound power level Cooling
Nom.
dBA
Sound pressure
level
Cooling
Nom.
dBA
Night quiet mode Cooling
dBA
Compressor
Type
Hermetically sealed swing compressor
Hermetically sealed scroll compressor
Operation range
Water side
Cooling Min.~Max. °CDB
Air side
Cooling Min.~Max. °CDB
Refrigerant
Type
R-410A
Charge
kg
Control
Electronic expansion valve
Circuits
Quantity
Water circuit
Piping connections diameter
inch
G 5/4" (female)
Piping
inch
Piping
connections
Water heat exchanger inlet / outlet
Water heat exchanger drain
Hose nipple 1/2" FBSP
Power supply
Phase / Frequency / Voltage
Hz / V
Digital controller
230
5.2
6.0
7.1
8.5
9.5
11.0
1.89
2.35
2.95
2.74
3.19
3.82
2.75
2.55
2.41
3.11
2.98
2.88
3.75
3.83
3.87
4.57
4.52
4.46
805x1,190x360
1,435x1,418x382
100
180
-
1.01
14.9
17.2
20.4
24.4
27.2
31.5
49.4
45.1
38.3
58.0
54.6
49.1
6
10
-
96
100
97
-
780
-
8
62
63
64
48
50
51
-
45
5~20
5~22
10~43
10~46
1.7
2.95
1
-
-
5/4"
1" MBSP
-
-
1~ / 50 / 230
230
EWAQ-ACV3
EWAQ005-011ACV3
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
231 231 Cooling only Indoor units 009 011 013 Cooling capacity Nom. kW Power input Cooling Nom. kW EERESEERDimensions Unit HeightxWidthxDepth mm Weight Unit kg Water heat exchanger Type Brazed plate Water volume l Nominal water flow Cooling l/min Air heat exchanger Type Hi-XSS Pump Nominal ESP unit ...
232 232 Air cooled mini chiller inverter › Inverter technology ensures: continuous match of requested load ; excellent part load efficiency (ESEER up to 4.57) ; significant reduction of starting currents ; precise temperature control (evaporator leaving water) › Low operating sound level › Easy ‘plu...
234 234 Cooling only Capacity class 5 8 10 Cooling capacity Nom. kW Capacity steps % Power input Cooling Nom. kW EERDimensions Unit HeightxWidthxDepth mm Weight Unit kg Operation weight kg Water heat exchanger - evaporator Type Brazed plate, one per circuit Minimum water volume in the system l Water...