Covers safety regulations, technical specifications, product description, battery installation, button functions, display indicators, measurement modes (single distance and continuous tracking), calculations (addition, subtraction, area, volume, Pythagoras theorem), measurement conditions, error codes and troubleshooting, utilization and recycling, warranty terms, and care and maintenance.

The device is a class 2 laser product with a measurement range up to 30 meters and an accuracy of ±3 mm. It is intended for indoor and outdoor building applications.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 1 – Safety, Specifications, and Basic Operations
  • Page 2 – Error Codes, Warranty, and Maintenance
  • Page 3 – Safety, Specifications, and Controls
  • Page 4 – Error Codes, Care, and Warranty
  • Page 5 – Safety, Specifications, and Calculations
  • Page 6 – Maintenance, Error Codes, and Warranty
  • Page 7 – Safety, Specifications, and Operations
  • Page 8 – Error Codes, Maintenance, and Warranty
Loading the manual

Laser distance meter

Vector 30

User manual

Congratulations on your purchase of laser distance meter Vector 30 CONDTROL.

Safety instructions can be found in the end of this user manual and should be carefully read before you use the device for the first time.

SAFETY REGULATIONS

The user manual should be read carefully before you use the device for the first time. Unintended use of the device can be dangerous for human health and cause serious injury. If the device is given to somebody for temporary use, be sure to enclose user manual to it.

  • Do not misuse the device.
  • Do not remove warning signs and protect them from abrasion, because they contain information about safe operation of the device.

The device belongs to laser class 2 in accordance with EN60825-1.

Laser radiation!

Do not stare into beam

Class 2 laser

<1 mW 620-690nm

EN60825-1:2014

  • Do not look into the laser beam or its reflection, with unprotected eye or through an optical instrument. Do not point the laser beam at people or animals without the need. You can dazzle them or look aside.
  • To protect your eyes close them or look aside.

It is prohibited to disassemble or repair the device yourself. Entrust the device repair to qualified personnel and use original spare parts only.

  • Do not use the device in explosive environment, close to flammable materials.
  • Avoid heating the batteries to avoid the risk of explosion and electrolyte leakage. In case of liquid contact with skin, wash it immediately with soap and water. In case of liquid contact with eyes, flush with clean water during 10 minutes and consult the doctor.

INTENDED USE

Laser distance meter Vector 30 is intended to measure distance, to calculate area and volume of measured objects and perform calculations by and Pythagoras' Theorem. The device is suitable for use at both indoor and outdoor building areas.

TECHNICAL SPECIFICATIONS

Measuring range*

0,05...30 m

Smallest unit displayed

1 mm

Measuring accuracy **

±3 mm

Laser

Class II, 620-690 nm, <1 mW

Continuous measurement

+

Addition/subtraction

+

Area/volume

+

Calculations by Pythagoras' Theorem

+

Automatic shutdown of the laser

30 seconds

Automatic shutdown of the device

180 seconds

Battery life

Up to 5000 measurements

Storage temperature

-20...+70 °C

Operating temperature

0...+40 °C

Dust and water protection rate

IP54

Power supply

2 x 1.5V AAA LR03 (alkaline)

Dimensions

115x39x19 mm

Weight

42 g

  • Use a target plate to increase the measurement range during daylight or if the target has poor reflection properties.

** Accuracy can decrease under unfavorable conditions, such as intense sunshine or when measurements are made against glossy or transparent surfaces, moving objects, objects with rough surface or when laser beam is reflected.

Switch on/off

To switch on the device short press the button DIST . The device will switch on and enter single distance measurement mode.

DELIVERY PACKAGE

1. Laser distance meter - 1 pc.

2. Hand strap - 1 pc.

3. Battery manual - 1 pc.

4. Batteries 2 x 1.5V AAA LR03

PRODUCT DESCRIPTION

Functions of buttons

Button | Short press | Long press

1 | Switch on the device/ switch on the laser beam/single distance measurement | Continuous measurement (tracking)

2 | Area/volume/Pythagoras | Select measuring unit

3 | Addition/subtraction | Select reference point

4 | Delete the measurement result/exit the mode | Switch off the device

Display

1. Main line for displaying measurement/calculation results

2. Additional line for displaying measurement/calculation results

3. Indication of the mode

4. Battery charge level indication

5. Measuring unit

6. Indication of the reference point

Insert/replace batteries

Remove the battery cover. Insert the batteries, observing correct polarity. Put the battery cover back.

Replace the batteries as soon as the error 203 appears on the display. Remove the batteries from the device if it's not used for a long time to avoid corrosion and battery discharge. All batteries must be replaced at the same time. Both batteries must be of the same brand, with the same charge level.

To switch off the device press and hold the button COff during 3 seconds.

In order to save the battery power the device will switch off automatically within 180 seconds after the last operation.

Reference point

It is possible to set the reference point either from the top or the bottom end of the device. The default reference point is the bottom end of the device. To select the reference point press and hold the button ± during 2 seconds. Corresponding indicator will appear on the display - or .

Measuring unit

To select required measuring unit (m, in, ft) press and hold the button U during 2 seconds.

MEASUREMENTS

Single distance measurement

Short press the button DIST to switch on the device. Laser beam will be switched on automatically. Aim the laser beam at the object of measurement and short press the button DIST to make a single distance measurement. Measurement result will appear on the display. Short press the button COff to delete the result of measurement and exit the mode.

Continuous measurement (tracking)

Press and hold the button DIST during 3 seconds. The device will take measurements one after another, showing the last measured value in the main line, and the previous measured value in the first line. Short press the button DIST to stop measuring. Short press the button COff to exit the mode.

CALCULATIONS

Addition/subtraction

Make a measurement. Short press the button ± to select either addition or subtraction, and make the 2nd measurement. Calculation result will appear in the main line on the display. The next measurements will also be added/subtracted to/from the next measuring result.

Area

Short press the button F once. Symbol will appear on the display. Laser beam will be on. Short press the button DIST to measure the 1st side (length). Short press the button DIST to measure the 2nd side (width). Area (composition of length and width) will be calculated and appear in the main line on the display.

Short press the button COff to exit the mode.

Volume

Short press the button F twice. Symbol will appear on the display. Laser beam will be on. Short press the button DIST to measure the 1st side (length). Short press the button DIST to measure the 2nd side (width). Short press the button DIST to measure the 3rd side (height). Volume (composition of length, width and height) will be calculated and appear in the main line on the display.

Short press the button COff to exit the mode.

Indirect measurement by Pythagoras' Theorem

Calculation of distance by using 2 additional measurements

Short press the button U 3 times. Symbol will appear on the display. Make measurements of distance A and B. Length of distance C will be calculated and the result will appear in the main line. Distance B must be perpendicular to distance C and cannot be longer than distance A.

Short press the button COff to exit the mode.

Calculation of distance by using 3 additional measurements

Distance D can be measured by making 3 additional measurements. Short press the button U 4 times. Symbol will appear on the display. Laser beam will be on. Make measurements of distances A, B and C one by one.

After the last made measurement calculation result (distance D) will appear in the main line on the display.

Short press the button COff to exit the mode.

MEASUREMENT CONDITIONS

Measurement range

The maximum measurement range is 30 m. At night, at dusk, or if the object of measurement is shaded, the measurement range can be increased without the use of the reflective plate. Use a reflective plate to increase the measurement range during daylight hours, or if the object being measured has a poor reflective surface.

Object surface

When measuring up to colorless liquids (e.g. water), dust-free glass, polystyrene or similar translucent and glossy surfaces, the measurement results may be wrong. When measuring to very dark surfaces, the measurement time may increase.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 1 - Safety, Specifications, and Basic Operations

Introduction to the device including safety regulations, intended use, technical specifications, delivery package, button functions, display indicators, battery installation, power on/off, reference point selection, measuring units, and measurement modes such as single distance and continuous tracking....

Page 2 - Error Codes, Warranty, and Maintenance

List of error codes with problems and solutions, utilization instructions for recycling, warranty terms covering 24 months with conditions and exclusions, and care and maintenance guidelines including cleaning and battery precautions.

Page 3 - Safety, Specifications, and Controls

Covers safety instructions, technical specifications, delivery scope, product description with button functions and display, battery installation, switching on/off, reference point selection, measuring units, and measurement modes including single and continuous measurements.

Tips

  • Always use a target plate to improve measurement range in bright daylight or on low-reflectivity surfaces.
  • Replace batteries as soon as error 203 appears to avoid inaccurate readings.
  • Avoid measuring on transparent or glossy surfaces to prevent errors.
  • Store the device in its case when not in use.
  • Clean the optics with a soft cloth.
  • If the device is not used for a long time, remove the batteries to prevent leakage.
  • Perform control measurements periodically, especially after mechanical impacts.
  • Do not disassemble the device; refer to authorized service centers for repairs.