Page 2 - Rack-Mount Kit Overview; Equipment Rack Descriptions; Figure 1
2 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Rack-Mount Kit Overview Rack-Mount Kit Overview This section describes the types of racks for which this rack-mounting kit is intended, and themounting configurations that are possible with each type. Equipment Rack Descriptions Th...
Page 3 - Rack-Mount Installation Summary
Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 3 Rack-Mount Kit Overview Rack-Mount Installation Summary Following is a summary of the installation procedures required to rack-mount the chassis. Thissummary is informational and is not intended to replace the actual procedures req...
Page 4 - Figure 2 shows the components in this mounting kit.; Figure 2
4 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Rack-Mount Kit Overview Figure 2 shows the components in this mounting kit. Figure 2 Rack-Mount Kit Components Each of the chassis ears attaches to a side of the chassis with two M4 x 10-mm, Phillips, flat-headscrews). When the cha...
Page 6 - Figure 4 shows a typical flush-mount installation.; Figure 4
6 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Rack-Mount Kit Overview Figure 4 shows a typical flush-mount installation. Figure 4 Typical Flush-Mount Installation—For Telco Racks Bolted to the Floor UPPERPOWER LOWERPOWER NORMAL Cisco 7000 H2293
Page 7 - Prerequisites
Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 7 Prerequisites Prerequisites Before you begin this installation, review the safety guidelines in this section to avoid injuringyourself or damaging the equipment. This section also provides descriptions of the tools and partsyou nee...
Page 8 - Safety Guidelines; Warning; Working with Electrical Equipment
8 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Prerequisites Safety Guidelines Review the following guidelines to help ensure your safety and protect the equipment from damageduring the installation. Warning Before working on a system that has an on/off switch, turn OFF the pow...
Page 9 - Grasp the underside of the chassis exterior with both hands.
Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 9 Prerequisites • Ensure that your footing is solid and balance the weight of the object between your feet. • Lift the object slowly; never move suddenly or twist your body as you lift. • Keep your back straight and lift with your le...
Page 10 - Safety with Electricity
10 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Prerequisites Safety with Electricity Follow these basic guidelines when working with any electrical equipment: • Before beginning any procedures requiring access to the chassis interior, locate the emergencypower-off switch for t...
Page 11 - Equipment Rack Considerations
Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 11 Prerequisites When you replace the power supplies, remember to engage all of the safety features on each supply.The power supplies feature the following three safety interlock features: • A safety interlock on/off switch (see Figu...
Page 12 - Rack Stability; Figure 7
12 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Prerequisites Rack Stability When installing the chassis in any rack that is not secured to the floor or overhead structure, placethe chassis in the lower half of the rack. A fully-configured chassis weighs 145 pounds (65.8 kg),an...
Page 13 - with the heaviest component at the bottom of the rack.
Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 13 Prerequisites Also, when installing the chassis in Telco-type racks, ensure that the rack is secured to the floor orotherwise stabilized. Center-mount the chassis if possible (and practical for your installation). Doingso places t...
Page 14 - Rack Dimensions and Site Layout
14 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Prerequisites Rack Dimensions and Site Layout For complete site requirements and recommendations, refer to the Cisco 7000 Hardware Installationand Maintenance or Cisco 7507 Hardware Installation and Maintenance publications. To he...
Page 15 - List of Parts and Tools; Tools Required
Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 15 Prerequisites List of Parts and Tools This section lists the tools you will need to complete this installation and the parts that are shippedas part of the rack-mount kit. Ensure that you have all the tools and parts required so t...
Page 16 - Installation; Installing the Brackets; Figure 9
16 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Installation Installation The following sections describe the procedures for mounting the chassis in a 19-inch equipment rackwith two or four mounting posts. Before proceeding, review the guidelines and recommendations inthe secti...
Page 17 - Mounting the Brackets to the Rack Posts; Installing a Bracket on a Rack Post—Left Bracket Shown
Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 17 Installation After you install both brackets in the rack, you must connect the spanner bar on each bracket to theopposite bracket. The spanner bars are required to prevent both ends of the brackets (at the front andrear of the rac...
Page 18 - screws when attaching the spanner bars later.; Caution; Securing the Spanner Bars
18 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Installation Step 4 Slide the bracket up and down along the mounting post to align the mounting holes in thebracket with those in the rack post. Step 5 While supporting the bracket with one hand, use the other hand to insert a 10-...
Page 20 - Attaching the Chassis Ears; Installing the Ears on the Chassis
20 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Installation Attaching the Chassis Ears The ears attach directly to the chassis with four M4 x 10-mm, flat-head screws. Attach the ears tothe chassis before you slide the chassis onto the brackets and back into the rack. After you...
Page 21 - Follow these steps to install the ears on the chassis:; Installing the Chassis in the Rack; Removing Power Supplies and Interface Cables
Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 21 Installation Follow these steps to install the ears on the chassis: Step 1 While referring to Figure 12, position the ears on the chassis as follows: • To flush-mount the chassis (so that the end of the chassis is approximately fl...
Page 22 - Proceed to the next section to move the chassis into the rack.
22 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Installation Step 6 If a second power supply is installed, repeat steps Steps 3 through 5 to remove the secondsupply. Figure 13 Handling a Power Supply (AC-Input Power Supply Shown) Warning To avoid dropping the power supply and i...
Page 23 - This completes the procedure for moving the chassis into the rack.
Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 23 Installation Figure 14 Chassis Foot If you have not already done so, review the safety guidelines in the section “Lifting the ChassisSafely” on page 8. Then follow these steps to install the chassis in the rack: Step 1 Two people ...
Page 24 - Checking Electrical Isolation; Note
24 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Installation Figure 15 Sliding the Chassis into the Rack Checking Electrical Isolation The inner sides of the mounting brackets and the grommets on the chassis ears are shielded to isolatethe chassis from contact with the equipmen...
Page 25 - Replacing Power Supplies and Interface Cables; Repeat Steps 2 through 6 for the second power supply, if any.
Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 25 Installation Replacing Power Supplies and Interface Cables Before proceeding, ensure that you have sufficient working space (at least three feet) behind thechassis, and that access to the power supply bays is not blocked by an equ...
Page 26 - Restarting the System; Check the following components to make sure they are secure:
26 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Installation Restarting the System To complete the installation, you will perform a final check of all connections, then restart thesystem. This procedure is not for new systems; perform this procedure only if you have alreadyconn...
Page 27 - Router name
Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 27 Installation Figure 16 Cisco 7000 Port Configuration Worksheet Circle one: AIP/CIP/EIP/FIP/FSIP/HIP/TRIP 0/0 0/1 0/2 0/3 0/4 0/5 0/6 0/7 Slot 3 3/0 3/1 3/2 3/3 3/4 3/5 3/6 3/7 Slot 4 4/0 4/1 4/2 4/3 4/4 4/5 4/6 4/7 Router name Loc...
Page 29 - Translated Safety Warnings; Power Disconnection Warning; siitä virta ja kytke virtajohto irti.; Power Supply Warning
Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 29 Translated Safety Warnings Translated Safety Warnings Following are translations of the safety warnings that appear throughout this publication: Power Disconnection Warning Warning Before working on a system that has an on/off swi...
Page 30 - Power Supply Disconnection Warning; AC units disconnect the power at the circuit breaker on DC units.
30 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Translated Safety Warnings Varoitus Älä kosketa virtalähdettä virtajohdon ollessa kytkettynä. Virrankatkaisimella varustetuissa järjestelmissä on virtalähteen sisällä jäljellä verkkojännite, vaikka virrankatkaisin onkatkaistu-asen...
Page 31 - Electric Shock Warning; disconnect the two power supply cords before servicing the unit.
Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 31 Translated Safety Warnings Attention Avant de travailler sur un châssis ou à proximité d'une alimentation électrique, débrancher le cordon d'alimentation des unités en courant alternatif ; couper l'alimentation des unitésen couran...
Page 32 - Chassis Lifting Warning
32 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Translated Safety Warnings ¡Advertencia! Puede ser que este equipo posea más de un cable de alimentación. Para reducir el riesgo de descarga eléctrica, desenchufar los dos cables antes de proceder al mantenimiento de launidad. Var...
Page 33 - DC Power Disconnection Warning
Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 33 Translated Safety Warnings Advarsel Det er nødvendig med to personer for å løfte kabinettet. Ta tak i kabinettet under den nedre kanten, og løft med begge hender. Unngå personskade ved å holde ryggen rett og løfte medbena, ikke ry...
Page 34 - Lightning Activity Warning; werken of kabels aan te sluiten of te ontkoppelen.
34 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Translated Safety Warnings Avvertenza Prima di svolgere una qualsiasi delle procedure seguenti, verificare che il circuito CC non sia alimentato. Per verificare che tutta l’alimentazione sia scollegata (OFF), individuarel’interrut...
Page 35 - Chassis Warning—Rack-Mounting and Servicing; Waarschuwing; naar boven te laden met het zwaarste onderdeel onderaan in het rek.; Varoitus; kaikkein raskaimmalla esineellä ja siirry sitten sen yläosaan.; Attention; en plaçant l'élément le plus lourd dans le bas.
Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 35 Translated Safety Warnings Chassis Warning—Rack-Mounting and Servicing Warning To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. Th...
Page 36 - montare nel supporto.; Advarsel; bunnen og opp med den tyngste komponenten nederst i kabinettet.; Aviso; na parte inferior da estante, arrumando-os de baixo para cima.
36 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Translated Safety Warnings Warnung Zur Vermeidung von Körperverletzung beim Anbringen oder Warten dieser Einheit in einem Gestell müssen Sie besondere Vorkehrungen treffen, um sicherzustellen, daß das Systemstabil bleibt. Die folg...
Page 37 - Ramp Warning
Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions 37 Translated Safety Warnings Varning! För att undvika kroppsskada när du installerar eller utför underhållsarbete på denna enhet på en ställning måste du vidta särskilda försiktighetsåtgärder för att försäkra dig om att systemet stå...
Page 38 - Cisco Information Online; You can access CIO in the following ways:
38 Cisco 7000 and Cisco 7507 Rack-Mount Kit Installation Instructions Cisco Information Online Cisco Information Online Cisco Information Online (CIO) is Cisco Systems’ primary, real-time support channel. Maintenancecustomers and partners can self-register on CIO to obtain additional content and ser...