Cisco CAB-449FC - Manual
Cisco CAB-449FC – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Serial Cable CAB−449MT; EIA/TIA−449 Serial Cable Assembly
- Page 4 – Serial Cable CAB−449FC
- Page 5 – Related Information
CAB−449MT and CAB−449FC EIA/TIA−449 Serial
Cable Specifications
Document ID: 46801
Introduction
Prerequisites
Requirements
Components Used
Conventions
EIA/TIA−449 Speed and Distance Limitations
Serial Cable CAB−449MT
EIA/TIA−449 Serial Cable Assembly
EIA/TIA−449 DTE Cable Pinouts
Serial Cable CAB−449FC
EIA/TIA−449 DCE Cable Pinouts (DB−60 to DB−37)
Related Information
Introduction
This document provides the technical and cable specifications for the EIA/TIA−449 serial cables.
Prerequisites
Requirements
There are no specific requirements for this document.
Components Used
This document is not restricted to specific software and hardware versions.
The information in this document was created from the devices in a specific lab environment. All of the
devices used in this document started with a cleared (default) configuration. If your network is live, make sure
that you understand the potential impact of any command.
Conventions
For more information on document conventions, see the Cisco Technical Tips Conventions.
EIA/TIA−449 Speed and Distance Limitations
The use of balanced drivers allows EIA/TIA−449 signals to travel greater distances than the EIA/TIA−232
standard. The table below lists the standard relationship between baud rate and maximum distance for
EIA/TIA−449 signals. These limits are also valid for V.35 and X.21.
Data Rate (Baud)
Distance (Feet)
Distance (Meters)
2400
4,100
1,250
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
4800 2,050 625 9600 1,025 312 19200 513 156 38400 256 78 56000 102 31 T1 50 15 Caution: The EIA/TIA−449 and V.35 interfaces support data rates up to 2.048 Mbps. Exceeding this maximum could result in loss of data and is not recommended. Serial Cable CAB−449MT This section presents the cable assembly...
1 Any pin not referenced is not connected. Serial Cable CAB−449FC This section presents the cable assembly and pinouts for the CAB−449FC serial cable. The cable gender for this product (part number 72−0796−01) is Male DB−60 to Female DB−37, mode −DCE. This cable is used in the following systems:the ...
J1−9 J1−10 RTS/CTS+ RTS/CTS− Twisted pairno. 5 −−−> −−−> J2−9 J2−27 CS+ CS− J1−29 J1−30 NIL/LL Circuit_GND Twisted pairno. 12 −−−> − J2−10 J2−37 LL SC J1−7 J1−8 DTR/DSR+ DTR/DSR− Twisted pairno. 4 −−−> −−−> J2−11 J2−29 DM+ DM− J1−3 J1−4 DSR/DTR+ DSR/DTR− Twisted pairno. 2 <−−− <...