INSTALLATION INSTRUCTIONS

EVCM-100D

Magna Lift™ Electric Ceiling Mount

Prior to assembly, unpack carton completely and verify contents.

If you are missing any of the following components, please contact Customer Service at 1-800/582-6480

BEFORE PROCEEDING, READ INSTALLATION INSTRUCTIONS COMPLETELY

WARNING! IMPROPER INSATLLATION MAY RESULT IN SERIOUS
PERSONAL INJURY! All components must be securely fastened to each other
and to the ceiling. The overhead support must be capable of supporting five times
the weight of the mount and equipment combined. If it cannot is MUST be
reinforced.

Unit Specifications

Motor Operation Limits

Run Time - 12 Minutes*

Cool Time - 25 Minutes

Run Time - 12 Minutes

Do not exceed two cycles without an extended cooling period of 45 minutes. To prevent
damage to the Magna Lift, the unit will shut down for cooling if overheated.

* It will take approximately 11 minutes to fully lower and raise 20 feet of cable under maximum load.

Maximum Weight Capacity ....................... 250 lbs. (113.5)
Maximum Travel ....................................... 20 feet (609.6 cm)
Unit Weigh

t

................................................ 48 lbs. (21.6 kg)

Electrical Requirements ........................... 115 volts, 60 Hz, 1.6 amps continuous

Read instructions completely before installing unit and connecting power.

1. Ensure 115-volt electrical power is readily available at the installation location.
2. Ensure support for the EVCM-100 ceiling mount is securely installed to the ceiling; if not

the ceiling must be reinforced. Improper installation may result in serious personal
injury.

3. Use the optional QD-1 for simplified installation or attach the EVCM-100 Magna-Lift

directly to the NPT 1 1/2" column installed in your ceiling as follows:

A Thread the unit on the NPT 1 1/2" column and tighten securely using pipe

wrench.

B After unit is tightened securely, install the thread locking set screw [Figure 1,

Item (1) into the coupler, tightening it against threads on column.