Chief CMA-345 - Manual

Chief CMA-345

Chief CMA-345 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

CHIEF MANUFACTURING INC.

8803-000019

1-800-582-6480

952-894-6280 FAX 952-894-6918

2003 Chief Manufacturing

12800 HIGHWAY 13 SOUTH, SUITE 500

www.chiefmfg.com

SAVAGE, MINNESOTA 55378 USA

01/03

I N S T A L L A T I O N I N S T R U C T I O N S

STRUCTURAL CEILING PLATE WITH FLEX JOINTS

CMA-345

The CMA-345, Structural Ceiling Plate with Flex Joint minimizes the transfer of shock and extreme
vibration from the plate to the equipment. By using any length of standard 1 1/2” NPT pipe threaded on both
ends, or extension column, you can extend the height capabilities to meet your needs.

WARNING: IMPROPER INSTALLATION MAY RESULT IN SERIOUS PERSONAL INJURY!

When mounting Chief Manufacturing accessories, the structural system and mounting method

MUST

be capable of supporting 5 times the combined weight of the total installation.

The maximum weight to be installed on the ceiling plate is 500 pounds (226.8 Kg).

Unpack and check contents:
(1) Structural Ceiling Plate CMA-345

(1) 5/16-18 Allen Set Screw

(1) 5/32” Allen Wrench

INSTALLATION INSTRUCTIONS

1. Secure ceiling plate to structural member.

(SEE WARNING ABOVE)

Bolt hole spacing is shown on

Figure 1.

2. Thread your standard NPT 1 1/2” pipe or extension column into ceiling plate, tighten securely.
3. . Install and securely tighten the 5/16 – 18 socket set screw.

3.13

6.25

3.25

6.50

6X %%c.38

3.36

7.25

7.25

1 1/2" NPT

Figure 1. CMA-345 Dimensions

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Chief Models

All Chief Other