Bryant FF1DNA - Manual

Bryant FF1DNA

Bryant FF1DNA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – MODEL NUMBER NOMENCLATURE; PHYSICAL DATA; CLEARANCES; D—Major Series
  • Page 4 – SPECIFICATIONS; UNITS WITHOUT ELECTRIC HEATERS OR CONTROLS
  • Page 5 – SPECIFICATIONS Continued; UNITS WITH FACTORY-INSTALLED ELECTRIC HEATERS OR CONTROLS
  • Page 6 – SHC CORRECTION FACTOR
  • Page 7 – OTHER ACCESSORIES
  • Page 8 – SERVICE TRAINING; Packaged Service Training; programs are an excellent way to increase your; Classroom Service Training
Loading the manual

Form No. PDS FF1D.18.2

FAN COIL UNITS

FF1DNA,

FF1DNE

Sizes 018, 024, 030

FEATURES

The FF1DNA and FF1DNE Fan Coil units are designed as
upflow indoor air handlers for split-system heat pumps and air
conditioners. They are available with factory- or field-installed
electric heaters both of which include the disconnect. A field-
installed cooling control with disconnect is also available. A TDR
(Time Delay Relay) is included with either the electric heat or
the cooling control packages. The FF1DNE models are avail-
able with a factory installed TXV.
This fan coil may be installed free standing, wall hung or flush
mounted in the wall. The 22-in. wide cabinet size in all models
allows units to fit between standard stud spacings. No return air
ductwork is required if the application provides for return air in
the front of the cabinet through either a louvered closet door or
an optional accessory decorative grille panel.
The cabinet exterior is made of pre-painted galvanized sheet
metal. The cabinet is fully insulated to meet applications in con-
ditioned space. Additional insulation is required if the unit is
installed in an unconditioned space. Unit is supplied with
replaceable filter.
Multispeed direct-drive PSC blower motors have been selected
to provide the proper air handling for both heating and cooling.
Motors are suspended at 3 points on rubber grommets for qui-
eter operation.
All refrigerant lines, electrical power, and thermostat wiring
enter from the top of the cabinet. Sweat-type refrigerant con-
nections on both liquid and suction lines make for swift, low-cost
installation. All service access to the unit is conveniently located
in the front.

The CHECK-FLO-RATER

®

piston ensures efficient and

dependable refrigerant metering, and eliminates potential ser-
vice requirements of other metering devices. The CHECK-FLO-
RATER

®

is located inside the unit, easily accessible for piston

maintenance or changeout.
In addition, units can be factory ordered with a hard shut-off
thermostatic expansion valve (TXV) metering device for perfor-
mance improvement.
The drain pan is constructed of high-impact, sound-deadening,
corrosion-proof polyester resin. Primary and secondary drain
connections exit from the bottom or either side of the cabinet.

FF1D

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - MODEL NUMBER NOMENCLATURE; PHYSICAL DATA; CLEARANCES; D—Major Series

—2— MODEL NUMBER NOMENCLATURE CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. PHYSICAL DATA NOTE: Rough-in dimensions are 38-1/4 x 22-1/4 inches. CLEARANCES A minimum clearance of 21 in. is required in front of the access panels for servicing. Please note that this clearance ...

Page 4 - SPECIFICATIONS; UNITS WITHOUT ELECTRIC HEATERS OR CONTROLS

—4— SPECIFICATIONS See notes on page 5. UNITS WITHOUT ELECTRIC HEATERS OR CONTROLS UNIT SIZE 0180 0240 0300 RATINGS & PERFORMANCES Nominal Capacity (Btuh)* 18,000 24,000 30,000 Nominal Airflow (CFM) 650 870 1080 ELECTRICAL Unit Volts-Phase (60 Hz) 208/230—1 208/230—1 208/230—1 Operating Voltage ...

Page 5 - SPECIFICATIONS Continued; UNITS WITH FACTORY-INSTALLED ELECTRIC HEATERS OR CONTROLS

—5— SPECIFICATIONS Continued * Rated in accordance with U.S. Government DOE test procedures and/or ARI Standard 210/240-94. † Use copper wire only. Use 75°C in this application. When using non-metallic (NM) sheathed cable, wire size required should be based on that of 60°C con- ductors, instead of w...

Other Bryant Models

All Bryant Other