- Page 2 – DIMENSIONS
- Page 3 – RECOMMENDED TUBE DIAMETERS; CERTIFICATION APPLIES ONLY
- Page 4 – SPECIFICATIONS
- Page 5 – SPECIFICATIONS Continued
- Page 8 – COMBINATION RATINGS
- Page 9 – COMBINATION RATINGS Continued
- Page 14 – EER; TXV
- Page 15 – DETAILED COOLING CAPACITIES*
- Page 17 – DETAILED COOLING CAPACITIES* Continued
- Page 23 – CONDENSER ONLY RATINGS*; SST
- Page 24 – CONDENSER ONLY RATINGS* Continued
- Page 25 – SYSTEM DESIGN SUMMARY; Do not apply capillary tube indoor coils to these units.
- Page 26 – MATCHED SYSTEM
- Page 28 – GUIDE SPECIFICATIONS; GENERAL
Form No. PDS 591B.18.1
DELUXE 11 SEER
AIR CONDITIONER
WITH PURON
®
(R-410A)
591B (60 Hz)
Sizes 018 thru 060
Bryant’s Quantum Plus 591B with Puron® provides features
which cannot be matched by any other family of equipment. The
591B is a Quantum Plus air conditioning system utilizing Br y-
ant’s unique Puron refrigerant. The environmentally sound
refrigerant allows you to make a responsible decision in the pro-
tection of the ear th’s ozone layer. Bryant’s Quantum Plus sys-
tems meet the Energy Star
®
guidelines for energy efficiency.
AVAILABLE OPTIONS
Puron® Environmentally Sound Refrigerant
—Is Bryant’s
unique refrigerant designed to help protect the environment.
Puron is an HFC refrigerant which does not contain chlorine that
can harm the ozone layer. The most impor tant advantage of
Puron refrigerant is that it has not been banned in future air con-
ditioning systems as the traditional refrigerant R-22 has been.
Puron refrigerant is in service in thousands of systems proving
highly reliable, environmentally sound performance.
Heavy Duty Inlet Grille
—The DuraGuard™ coil protector,
made of a coated steel wire grid with vertical 3/8 in. spacing, is
designed to help protect the coil from inclement weather, van-
dalism, and incidental damage. It provides protection while not
restricting airflow and maintaining ease of coil inspection and
cleaning.
High Efficiency Performance
—Is delivered through a combina-
tion of features including Bryant’s Puron refrigerant, unique scroll
compressor, and advanced heat transfer surfaces. Efficiency rat-
ings are 11 to 12.5 SEER (Seasonal Energy Efficiency Ratio).
Sophisticated heat transfer surfaces utilized in Bryant’s 591B
design allow heat to easily be transferred to the outdoor air and
require less energy. The unique scroll compressor found in the
591B design performs quietly and adds to the overall efficiency of
the system. Finally, Bryant’s unique Puron refrigerant operates
more efficiently than ordinary R-22 refrigerant found in other sys-
tems. The efficiency levels provided by the 591B provide end
users with lower costs of operation than traditional air condition-
ing systems.
Assured Future Service
—By utilizing the environmentally
sound refrigerant, Puron®, 591B models will remain ser viceable
well into the future. The Clean Air Act of 1990 has placed a cap
on production of most other refrigerants which has scheduled
reductions beginning in 2004. The resulting cap in production
ultimately results in a complete ban on many other refrigerants
in new equipment by the year 2010. These changes, required by
federal law, mean the supply of other refrigerants may be limited
in the near future making Puron the correct choice when consid-
ering long term serviceability.
Highly Reliable Performance
—Is delivered through the supe-
rior design of the system and componentr y. The reliability of
the existing Quantum Plus models has been proven to provide
the lowest incidence of warranty ser vice of any product in the
Bryant family in the past few years of ser vice. Long term reli-
ability is assured through the use of both high and lo w pres-
sure switches which will not allow the system to operate in the
event of a significant change in operating pressure. In doing
this, the system is protected from damage if an un usual condi-
tion arises. Finally, Bryant includes a special liquid line filter
drier designed to trap moisture and contaminants which could
otherwise shor ten the life of the system.
Application Versatility
—Bryant’s systems utilizing Puron
refrigerant have the same application guidelines as other sys-
tems. Applications which include long line sets (50 to 175 ft) or
applications which require the system to operate at low outdoor
temperatures (below 55°F) are approved under Bryant’s stan-
dard guidelines.
Bryant Coils and Fan Coils to Complete the System
—Bryant
specially designs both the outdoor product and indoor coil prod-
ucts to operate with assured reliability and performance. A wide
range of indoor coil options are listed in the ratings section of
this publication.
Special Protective Devices
—High and low pressure switches
and internal protection in the compressor including temperature
and current sensing overloads prevent operation under poten-
tially damaging circumstances. A special liquid line filter drier
designed to trap nearly 4 times the volume of contaminants of
standard driers provides superior protection from moisture
trapped in the system.
Electrical Range
—208/230v, single phase.
Wide Range of Sizes
—Available in seven sizes; 1-1/2, 2, 2-1/2,
3, 3-1/2, 4, and 5 tons.
Reliant Cabinet
—Galvanized steel is coated with powder paint
to provide a superior, long lasting appearance.
Totally Enclosed Fan Motor
—Protected from adverse weather
conditions.
Unit Design
—Enhanced copper and aluminum heat transfer
surfaces with vertical air discharge to direct air up and away
from the area.
External Service Valves
—Both service valves are back seating
type valves which are externally located. These unique valves
allow service technicians to evacuate or charge the system in
less time than standard ser vice valves.
Easy Serviceability
—One panel provides access to electrical
controls and compressor. Removal of wire dome gives access
to fan motor and removal of the top gives access to the coil.
Agency Approvals
—591B models are listed with UL, c-UL,
ARI, CEC, and CSA-EEV. Special endorsements have also
been awarded these products by Energy Star® which recog-
nizes energy efficient products.
Limited Warranty
—A standard five year warranty on parts with a
10 year limited warranty on the compressor. Optional warranties
are available through your Bryant distributor.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
—2— DIMENSIONS AIR DISCHARGE AIR DISCHARGE AIR IN AIR IN AIR IN 3 / 8 " DIA. TIEDOWN KNOCKOUTS (2) PLACES L K J E D C L NOTES: 1. ALLOW 30" CLEARANCE TO SERVICE SIDE OF UNIT, 48" ABOVE UNIT, 6" ON ONE SIDE, 12" ON REMAINING SIDE, AND 24" BETWEEN UNITS FOR PROPER AIRFLOW.2. MI...
—3— RECOMMENDED TUBE DIAMETERS * For tube sets greater than 50 ft, consult Application Guideline and Service Manual—Air Conditioners and Heat Pumps Using Puron® Refrigerant. CHECK-FLO-RATER® PISTON * Piston listed is for any approved non-capillary tube coil combination. Piston is shipped with outdoo...
—4— SPECIFICATIONS See notes on page 5. UNIT SIZE-SERIES 018-A 024-A 030-A 036-A Operating Weight (Lb) 168 178 188 198 ELECTRICAL Unit Volts—Hertz—Phase 208/230-60-1 Operating Voltage Range* 187-253 Compressor— Rated Load Amps 10.3 13.5 15.4 17.9 Locked Rotor Amps 51.0 61.0 73.0 100.0 Condenser Fan ...