Bryant 116B - Manual
Bryant 116B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – MODEL NUMBER NOMENCLATURE; STANDARD FEATURES
- Page 3 – REFRIGERANT PIPING LENGTH LIMITATIONS; Liquid Line Sizing
- Page 4 – REFRIGERANT CHARGE ADJUSTMENTS; LONG LINE APPLICATIONS; AC WITH PURON; VAPOR LINE SIZING AND COOLING CAPACITY LOSS
- Page 6 – ACCESSORY USAGE GUIDELINE; Accessory Description and Usage (Listed Alphabetically); Compressor Start Assist — PTC Type
- Page 8 – ELECTRICAL DATA
- Page 11 – CLEARANCES; Wall; IM
- Page 12 – TESTED AHRI COMBINATION RATINGS*; Equipment performance calculator can be accessed at:
- Page 18 – CONDENSER ONLY RATINGS
- Page 19 – CONDENSER ONLY RATINGS CONTINUED
- Page 22 – SYSTEM DESIGN SUMMARY
116B
Legacy
t
Line 16 Air Conditioner
with Puron
r
Refrigerant
1--1/2 to 5 Nominal Tons
Product Data
the environmentally sound refrigerant
Bryant’s Air Conditioners with Puron
r
refrigerant provide a
co llectio n o f featu res u n m atch ed b y an y o th er fam ily o f
equipment. The 116B has been designed utilizing Bryant’s Puron
refrigerant. The environmentally sound refrigerant allows you to
make a responsible decision in the protection of the earth’s ozone
layer.
This product has been designed and manufactured to meet
Energy Star
r
criteria for energy efficiency when matched with
appropriate coil components. Refer to the combination ratings in
the Product Data for system combinations that meet Energy Star
r
guidelines.
NOTE
:
Ratings contained in this document are subject to
change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up--to--date ratings
information.
INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S
14 -- 16.5 SEER/11.0-- 13.5 EER
S
Microtube Technology
t
refrigeration system
S
Indoor air quality accessories available
Sound
S
Sound level as low as 76 dBA
S
Sound level as low as 74 dBA with accessory sound
blanket
Comfort
S
System supports Edge
r
Thermidistat
t
or standard
thermostat controls
Reliability
S
Puron
r
refrigerant -- environmentally sound, won’t
deplete the ozone layer and low lifetime servce cost.
S
Scroll compressor
S
Internal pressure relief valve
S
Internal thermal overload
S
Filter drier
S
Balanced refrigeration system for maximum reliability
Durability
DuraGuard
t
protection package:
S
Solid, durable sheet metal construction
S
Dense wire coil guard standard
S
Baked--on, complete outer coverage, powder paint
Applications
S
Long--line -- up to 250 feet (76.20 m) total equivalent
length, up to 200 feet (60.96 m) condenser above
evaporator, or up to 80 ft. (24.38 m) evaporator above
condenser (See Longline Guide for more information.)
S
Low ambient (down to --20
_
F/--28.9
_
C)) with
accessory kit
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 14 N N N A A/N N N N N A/N A/N N A 1 1 6 B N A 0 3 6 0 0 0 0 Prod- uct Family Tier SEER Major Series Voltage Grille Variations Cooling Capacity Open Open Open Series 1=AC 1= Legacy RNC 6=16 SEER B=Puron N= 208 --- 230 --- 1 or 208/230 --- 1 A = ...
3 REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengths { for Cooling Only Systems with Puron r Refrigerant : The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor unit...
4 REFRIGERANT CHARGE ADJUSTMENTS Liquid Line Size Puron Charge oz/ft 3/8 0.60 (Factory charge for lineset = 9 oz) 5/16 0.40 1/4 0.27 Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz. When using other length or diameter liquid lines, charge adj...