Bryant 187B - Manual

Bryant 187B

Bryant 187B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
Page: / 14

Table of Contents:

  • Page 2 – INSTALLATION; Check Equipment and Job Site; Inspect Equipment; Install on a Solid, Level Mounting Pad; WARNING
  • Page 3 – Outdoor Unit Connected to Factory Approved Indoor; Refrigerant Tubing Connection Outdoor; CAUTION
  • Page 4 – Make Electrical Connections
  • Page 5 – Final Wiring Check; IMPORTANT; Compressor Crankcase Heater; UNIT OPERATION AND SAFETY HAZARD; PERSONAL INJURY HAZARD; SYSTEM FUNCTIONS AND SEQUENCE
  • Page 6 – Communication and Status Function Lights; For Evolution Control Only, Green communications; Amber Status Light; Compressor Operation; NOTE; Crankcase Heater Operation; Table 3 – Outdoor Fan Motor PWM; Time Delays
  • Page 7 – Evolution Controlled Low Ambient Cooling
  • Page 8 – Final Checks; CARE AND MAINTENANCE
  • Page 9 – TROUBLESHOOTING; Table 4 – Winding Resistance; 30 V Brown Out Protection Defeated:
  • Page 10 – MAJOR COMPONENTS; OAT Thermistor must be locked in place with spherical nib end; THERMISTOR CURVE
  • Page 11 – Table 6 – TROUBLESHOOTING
Loading the manual

Installation Instructions

187B (2 -- 5 TONS)

180B (3 TON TROPHY)

EVOLUTION

t

SERIES 2--STAGE AIR CONDITIONER

WITH PURON

R

REFRIGERANT

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other

conditions which may cause death, personal injury, or property
damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The qualified

installer or agency must use factory--authorized kits or accessories
when modifying this product. Refer to the individual instructions

packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,

and work gloves. Use quenching cloth for brazing operations.
Have fire extinguisher available. Read these instructions

thoroughly and follow all warnings or cautions included in

literature and attached to the unit. Consult local building codes and
current editions of the National Electrical Code ( NEC ) NFPA 70.

In Canada, refer to current editions of the Canadian electrical code
CSA 22.1.

Recognize safety information. This is the safety--alert symbol

!

!

When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury. Understand

these signal words; DANGER, WARNING, and CAUTION. These

words are used with the safety--alert symbol. DANGER identifies
the most serious hazards which

will

result in severe personal injury

or death. WARNING signifies hazards which

could

result in

personal injury or death. CAUTION is used to identify unsafe

practices which

would

result in minor personal injury or product

and property damage. NOTE is used to highlight suggestions
which

will

result in enhanced installation, reliability, or operation.

!

WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury

or death.
Before installing, modifying, or servicing system, main

electrical disconnect switch must be in the OFF position and

install a lockout tag. There may be more than 1 disconnect

switch. Lock out and tag switch with a suitable warning label.

CUT HAZARD

Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and

wear appropriate protective clothing and gloves when

handling parts.

CAUTION

!

Indoor Thermostat Control Options

Model

Evolution

Control

Standard

2 --- stage

Thermostat

187B / 180B

Yes

Yes

INSTALLATION RECOMMENDATIONS

NOTE

: In some cases noise in the living area has been traced to

gas pulsations from improper installation of equipment.

1. Locate unit away from windows, patios, decks, etc. where

unit operation sound may disturb customer.

2. Ensure that vapor and liquid tube diameters are appropriate

for unit capacity.

3. Run refrigerant tubes as directly as possible by avoiding un-

necessary turns and bends.

4. Leave some slack between structure and unit to absorb vi-

bration.

5. When passing refrigerant tubes through the wall, seal open-

ing with RTV or other pliable silicon--based caulk. (See Fig.
1.)

6. Avoid direct tubing contact with water pipes, duct work,

floor joists, wall studs, floors, and walls.

7. Do not suspend refrigerant tubing from joists and studs with

a rigid wire or strap which comes in direct contact with
tubing.(See Fig. 1.)

8. Ensure that tubing insulation is pliable and completely sur-

rounds vapor tube.

9. When necessary, use hanger straps which are 1 in. (25.4

mm) wide and conform to shape of tubing insulation. (See
Fig. 1.)

10. Isolate hanger straps from insulation by using metal sleeves

bent to conform to shape of insulation.

INSULATION

VAPOR TUBE

LIQUID TUBE

OUTDOOR WALL

INDOOR WALL

LIQUID TUBE

VAPOR TUBE

INSULATION

CAULK

Avoid contact between tubing and structure

NOTE:

THROUGH THE WALL

HANGER STRAP

(AROUND VAPORTUBE ONLY)

JOIST

1” (25.4 mm) MIN.

SUSPENSION

A94026

Fig. 1 -- Piping Installation

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; Check Equipment and Job Site; Inspect Equipment; Install on a Solid, Level Mounting Pad; WARNING

2 The outdoor unit contains system refrigerant charge for operationwith AHRI rated indoor unit when connected by 15 ft. (4.57 m) of field--supplied or factory accessory tubing. For proper unitoperation, check refrigerant charge using charging information located on control box cover and/or in the Ch...

Page 3 - Outdoor Unit Connected to Factory Approved Indoor; Refrigerant Tubing Connection Outdoor; CAUTION

3 Table 1 – Accessory Usage ACCESSORY REQUIRED FOR LOW --- AMBIENT COOLING APPLICATIONS (Below 55 ° F/12.8 _ C) REQUIRED FOR LONG LINE APPLICATIONS* REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles/3.22 km) Compressor Start Assist Kit No Yes No Crankcase Heater Standard Standard Standard Evaporat...

Page 4 - Make Electrical Connections

4 Refer to Fig. 3 and install filter drier as follows: 1. Braze 5--in. liquid tube to the indoor coil.2. Wrap filter drier with damp cloth.3. Braze filter drier to above 5--in. (127 mm) liquid tube. Flow arrow must point towards indoor coil. 4. Connect and braze liquid refrigerant tube to the filter...

Other Bryant Models

All Bryant Other