Bryant 224A - Manual

Bryant 224A

Bryant 224A – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – INSTALLATION; Unpack Unit; NOTE; WARNING; PERSONAL INJURY AND ENVIRONMENTAL; CAUTION; UNIT DAMAGE HAZARD
  • Page 3 – Table 1 – Accessory Usage; Outdoor Unit Connected To Factory Approved Indoor; Install Liquid Line Filter Drier Indoor
  • Page 4 – Deep Vacuum Method; Final Tubing Check; Make Electrical Connections; Route Ground and Power Wires; Connect Control Wiring
  • Page 5 – Final Wiring Check; Compressor Crankcase Heater; Follow these steps to properly start up system:
  • Page 6 – Check Charge; Heating Check Chart Procedure; Final Checks
Loading the manual

223A, 224A

Legacy

t

Line Heat Pump

with Puron

r

Refrigerant

1--1/2 To 5 Nominal Tons (Sizes 018 to 060)

Installation Instructions

NOTE

: Read the entire instruction manual before starting the

installation.

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,

or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury, or property

damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories

when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,

and work gloves. Use quenching cloth for brazing operations.
Have fire extinguisher available. Read these instructions

thoroughly and follow all warnings or cautions included in
literature and attached to the unit. Consult local building codes and

National Electrical Code (NEC) for special requirements.

Recognize safety information. This is the safety--alert symbol

!

!

.

When you see this symbol on the unit and in instructions or

manuals, be alert to the potential for personal injury.
Understand these signal words; DANGER, WARNING, and
CAUTION. These words are used with the safety--alert symbol.

DANGER identifies the most serious hazards which

will

result in

severe personal injury or death.

WARNING signifies hazards

which

could

result in personal injury or death. CAUTION is used

to identify unsafe practices which

may

result in minor personal

injury or product and property damage. NOTE is used to highlight

suggestions which

will

result in enhanced installation, reliability, or

operation.

!

WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury

or death.
Before installing, modifying, or servicing system, main

electrical disconnect switch must be in the OFF position.

There may be more than 1 disconnect switch. Lock out and

tag switch with a suitable warning label.

INSTALLATION RECOMMENDATIONS

NOTE

: In some cases noise in the living area has been traced to

gas pulsations from improper installation of equipment.

1. Locate unit away from windows, patios, decks, etc. where

unit operation sound may disturb customer.

2. Ensure that vapor and liquid tube diameters are appropriate

for unit capacity.

3. Run refrigerant tubes as directly as possible by avoiding

unnecessary turns and bends.

4. Leave some slack between structure and unit to absorb

vibration.

5. When passing refrigerant tubes through the wall, seal

opening with RTV or other pliable silicon--based caulk.

(See Fig. 1.)

6. Avoid direct tubing contact with water pipes, duct work,

floor joists, wall studs, floors, and walls.

7. Do not suspend refrigerant tubing from joists and studs with

a rigid wire or strap which comes in direct contact with

tubing.(See Fig. 1.)

8. Ensure that tubing insulation is pliable and completely

surrounds vapor tube.

9. When necessary, use hanger straps which are 1 in. wide and

conform to shape of tubing insulation. (See Fig. 1.)

10. Isolate hanger straps from insulation by using metal sleeves

bent to conform to shape of insulation.

INSULATION

VAPOR TUBE

LIQUID TUBE

OUTDOOR WALL

INDOOR WALL

LIQUID TUBE

VAPOR TUBE

INSULATION

CAULK

Avoid contact between tubing and structure

NOTE:

THROUGH THE WALL

HANGER STRAP

(AROUND VAPOR

TUBE ONLY)

JOIST

1

MIN.

SUSPENSION

A94028

Fig. 1 -- Connecting Tubing Installation

When outdoor unit is connected to factory--approved indoor unit,

outdoor unit contains system refrigerant charge for operation with
ARI rated indoor unit when connected by 15 ft. (4.57 m) of

field--supplied or factory accessory tubing. For proper unit
operation, check refrigerant charge using charging information

located on control box cover and/or in the Check Charge section of
this instruction.

IMPORTANT

: Maximum liquid--line size is 3/8--in. OD for all

residential applications including line line.

IMPORTANT

: Always install the factory--supplied liquid--line

filter drier. Obtain replacement filter driers from your distributor or
branch.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; Unpack Unit; NOTE; WARNING; PERSONAL INJURY AND ENVIRONMENTAL; CAUTION; UNIT DAMAGE HAZARD

2 INSTALLATION Check Equipment and Job Site Unpack Unit Move to final location. Remove carton taking care not to damageunit. Inspect Equipment File claim with shipping company prior to installation if shipment is damaged or incomplete. Locate unit rating plate on unit cornerpanel. It contains inform...

Page 3 - Table 1 – Accessory Usage; Outdoor Unit Connected To Factory Approved Indoor; Install Liquid Line Filter Drier Indoor

3 Table 1 – Accessory Usage Accessory REQUIRED FOR LOW --- AMBIENT COOLING APPLICATIONS (Below 55 ° F / 12.8 ° C) REQUIRED FOR LONG LINE APPLICATIONS* (Over 80 ft. / 24.38 m) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles / 3.22 km) Accumulator Standard Standard Standard Ball Bearing Fan Motor ...

Page 4 - Deep Vacuum Method; Final Tubing Check; Make Electrical Connections; Route Ground and Power Wires; Connect Control Wiring

4 Deep Vacuum Method The deep vacuum method requires a vacuum pump capable of pulling a vacuum of 500 microns and a vacuum gage capable ofaccurately measuring this vacuum depth. The deep vacuum method is the most positive way of assuring a system is free of air andliquid water. A tight dry system wi...

Other Bryant Models

All Bryant Other