Bryant 312AAV/JAV

Bryant 312AAV/JAV – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
Page: / 56

Table of Contents:

  • Page 3 – SAFETY CONSIDERATIONS; WARNING; INTRODUCTION
  • Page 4 – NOTE; : Remove all shipping brackets and materials before
  • Page 5 – CODES AND STANDARDS; Follow all national and local codes and standards in addition; PRECAUTIONS PROCEDURE; FURNACE RELIABILITY HAZARD; CAUTION
  • Page 6 – LOCATION
  • Page 7 – FIRE, INJURY OR DEATH HAZARD; MINIMUM TO BURNERS; FIRE HAZARD; PROPERTY DAMAGE HAZARD; LOCATION RELATIVE TO COOLING EQUIPMENT; AIR FOR COMBUSTION AND
  • Page 8 – EXAMPLES: Determining Free Area; FURNACE
  • Page 10 – National Fuel Gas Code ANSI; Volume; ACH; other; Volume; ACH; fan; INSTALLATION
  • Page 12 – Platform Furnace Support; the ground underneath furnace must be level and the furnace set; Bottom Return Air Inlet; Tilt or raise furnace and remove 2 screws holding bottom; Side Return Air Inlet; side return air inlet(s) are used without a bottom return air inlet.; Combustible Floor
  • Page 15 – M IN
  • Page 19 – Table 6 – Maximum Capacity of Pipe; FURNACE DAMAGE HAZARD; UNION
  • Page 20 – ELECTRICAL CONNECTIONS; ELECTRICAL SHOCK AND FIRE HAZARD; FURNACE MAY NOT OPERATE HAZARD
  • Page 23 – Conditioner
  • Page 25 – : DO NOT connect furnace control HUM terminal to; VENTING; The furnace shall be connected to a listed factory built chimney
  • Page 26 – CARBON MONOXIDE POISONING HAZARD; GENERAL VENTING REQUIREMENTS
  • Page 29 – ADDITIONAL VENTING REQUIREMENTS; on the page following
  • Page 31 – following these figures; following these figures; then Up
  • Page 32 – complete application details. See Table 18 for accessory listing.
  • Page 33 – CHECK; Step 1 — General
  • Page 34 – Step 3 — Adjustments
  • Page 37 – FURNACE OVERHEATING HAZARD
  • Page 38 – COLOR
  • Page 39 – Table 14 – 2--Stage Furnace Blower OFF delay Setup Switch; DESIRED HEATING MODE; THERMOSTAT SUBBASE; CONTROL TERMINALS; Step 4 — Check Safety Controls; Step 5 — Checklist
  • Page 44 – Step 1 — Introduction
  • Page 45 – SERVICE; Step 2 — Care and Maintenance; FIRE OR EXPLOSION HAZARD; CARBON MONOXIDE POISONING AND FIRE; CUT HAZARD
  • Page 48 – UNIT DAMAGE HAZARD
  • Page 49 – Step 3 — Sequence of Operation
  • Page 50 – a. Inducer Prepurge Period
  • Page 52 – tinue as long as there is a call for cooling.; Continuous Blower Mode; Step 4 — Wiring Diagrams
  • Page 55 – Table 18 – Accessory List; DESCRIPTION
  • Page 56 – PARTS REPLACEMENT INFORMATION GUIDE; Consumer Relations Department
Loading the manual

Installation, Start--up, Operating and

Service and Maintenance Instructions

Series 140/E

312AAV/JAV

2--STAGE DELUXE, INDUCED COMBUSTION

4--WAY MULTIPOISE GAS FURNACE

SAFETY CONSIDERATIONS

2

. . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

CODES AND STANDARDS

5

. . . . . . . . . . . . . . . . . . . . . . . . . .

Safety

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

General Installation

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Combustion and Ventilation Air

5

. . . . . . . . . . . . . . . . . . . . . .

Duct Systems

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Acoustical Lining and Fibrous Glass Duct

5

. . . . . . . . . . . . . . .

Gas Piping and Gas Pipe Pressure Testing

5

. . . . . . . . . . . . . . .

Electrical Connections

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Venting

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS

PROCEDURE

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

LOCATION

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

AIR FOR COMBUSTION AND VENTILATION

7

. . . . . . . . .

INSTALLATION

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

UPFLOW INSTALLATION

10

. . . . . . . . . . . . . . . . . . . . . .

DOWNFLOW INSTALLATION

11

. . . . . . . . . . . . . . . . . . .

HORIZONTAL INSTALLATION

11

. . . . . . . . . . . . . . . . . .

FILTER ARRANGEMENT

15

. . . . . . . . . . . . . . . . . . . . . . .

AIR DUCTS

15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

GAS PIPING

17

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ELECTRICAL CONNECTIONS

21

. . . . . . . . . . . . . . . . . .

VENTING

26

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP, ADJUSTMENT, AND SAFETY CHECK

33

. . . . .

General

33

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Start--Up Procedures

34

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Adjustments

34

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Check Safety Controls

39

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Checklist

39

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SERVICE AND MAINTENANCE PROCEDURES

44

. . . . .

Introduction

44

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Care and Maintenance

45

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Sequence of Operation

49

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Wiring Diagrams

52

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Troubleshooting

52

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Accessory List

55

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PARTS REPLACEMENT INFORMATION GUIDE

56

. . . . .

D E

S I G N

C

E R

T I F I E

D

REGISTERED

ISO 9001:2000

Always Ask For

Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.

NOTE

: Read the entire instruction manual before starting the

installation.
Portions of the text and tables are reprinted from NFPA 54/ANSI
Z223.1--2009

E

, with permission of National Fire Protection

Association, Quincy, MA 02269 and American Gas Association,

Washington DC 20001. This reprinted material is not the
complete and official position of the NFPA or ANSI on the

referenced subject, which is represented only by the standard in
its entirety.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - SAFETY CONSIDERATIONS; WARNING; INTRODUCTION

3 SAFETY CONSIDERATIONS FIRE, EXPLOSION, ELECTRICAL SHOCK, AND CARBON MONOXIDE POISONING HAZARD Failure to follow this warning could result in dangerous operation, serious injury, death, or property damage.Improper installation, adjustment, alteration, service, maintenance, or use could cause carbon...

Page 4 - NOTE; : Remove all shipping brackets and materials before

4 gas. This furnace is not approved for installation in mobilehomes, recreational vehicles, or outdoors.These furnaces shall not be installed directly on carpeting, tile, orany other combustible material other than wood flooring. For downflow installations, a factory accessory floor base must be use...

Page 5 - CODES AND STANDARDS; Follow all national and local codes and standards in addition; PRECAUTIONS PROCEDURE; FURNACE RELIABILITY HAZARD; CAUTION

5 60 80 / 27 C / 16 C A06745 Fig. 3 -- Return Air Temperature CODES AND STANDARDS Follow all national and local codes and standards in addition to these instructions. The installation must comply with regulations of the serving gas supplier, local building, heating,plumbing, and other codes. In abse...

Other Bryant Models

All Bryant Other