Bryant 619FNQ - Manual
Bryant 619FNQ – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – Fig. 2 — Unit Dimensions
- Page 4 – Table 4A — 619FNF Physical Data
- Page 5 – Table 4B — 619FNQ Physical Data
- Page 6 – II. STEP 2 — LOCATING AND MOUNTING THE UNIT; Max. 2 louvers closed; Fig. 3 — Louver Positioning
- Page 8 – A. Locating the Room Controller; Do not; Frame support brackets; Fig. 10 — Condensate Drain Pipe; A AIR B; Fig. 13 — Gasket Location
- Page 9 – Fig. 14 — Room Controller Dimensions; Fig. 16 — Locating the Connection Cable; Connection Cable; Fig. 17 — Connecting the Room Controller; Mounting screws; Fig. 15 — Mounting the Room Controller
- Page 10 – Adjustable wrench or torque wrench
- Page 15 – Fig. 24 — 619FNF/538ENF Cooling Only System Wiring Diagram
- Page 18 – INTERNAL CONTROL PANEL; Fig. 27 — Internal Control Panel
- Page 19 – Diagram 1; REMOTE
- Page 20 – Air intake grille; Unit; Ø A; Fig. 30 — Installation Options; Supply air duct to adjacent room
- Page 21 – Cooling Only Remote; S with Swing Louver Icon; Represents the swing louver; A with Auto Louver Icon; Represents the auto louver; up
- Page 22 – ITEM; push; Or; Fig. 33 — Selecting the Louver Mode
- Page 23 – Table 9 — Fault Codes; CODE
- Page 24 – Fig. 35 — Warning Lamps and Emergency Button
Cancels: New
II 619F-18-1
4/1/06
installation, start-up and
service instructions
IN-CEILING CASSETTE
FAN COIL UNITS
619FNF
619FNQ
Sizes 018-03036
CONTENTS
Page
SAFETY CONSIDERATIONS
. . . . . . . . . . . . . . . . . . . . . . . . . 1
GENERAL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19
I. Step 1 — Complete Pre-Installation Checks
. . . . . . 2
II. Step 2 — Locating and Mounting the Unit
. . . . . . . . 6
III. Step 3 — Locating and Mounting the Room
Controller
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
IV. Step 4 — Complete Refrigerant Piping
Connections
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
V. Step 5 — Make Electrical Connections
. . . . . . . . . 11
INSTALLATION OPTIONS
. . . . . . . . . . . . . . . . . . . . . . . . 19-22
I. Fresh Air Intake
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
II. Conditioned Air Supply to Adjacent Room
. . . . . . 19
III. Room Controller Configuration Setup
. . . . . . . . . . 21
IV. Louver Mode Selection
. . . . . . . . . . . . . . . . . . . . . . 21
V. Main Board Configuration
. . . . . . . . . . . . . . . . . . . . 21
START-UP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22,23
SERVICE AND MAINTENANCE
. . . . . . . . . . . . . . . . . . . . . . 23
TROUBLESHOOTING
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23,24
SAFETY CONSIDERATIONS
Installing and servicing air-conditioning equipment can be
hazardous due to system pressure and electrical components.
Only trained and qualified service personnel should install or
service air-conditioning equipment.
Untrained personnel can perform basic maintenance, such as
cleaning and replacing filters. All other operations should be
performed by trained service personnel. When working on air
conditioning equipment, observe safety precautions in litera-
ture, tags, and labels attached to unit.
Follow all safety codes. Wear safety glasses and work gloves.
Use quenching cloth for brazing operations. Have fire extin-
guisher available. Read these instructions
thoroughly
. Con-
sult local building codes and the National Electrical Code
(NEC) for special installation requirements.
GENERAL
These instructions cover the installation, start-up and service
of in-ceiling cassette fan coil units. See Fig. 1.
The following accessories can be used with 619FNF, FNQ
units. See the price pages for part numbers and additional
information for the following accessories:
• photocatalytic and electrostatic filter with mount
• air supply outlet obstruction kit
• wired room controller
• room controller wiring kit for multiple units
• zone manager kit for multiple units
• zone manager
• infrared remote kit
WARNING:
Before installing or servicing system,
always turn off main power to system. There may be
more than one disconnect switch. Turn off accessory
heater power if applicable. Electrical shock can cause
serious personal injury.
CAUTION:
This system uses Puron® refrigerant
(R-410A), which has higher pressures than R-22 and
other refrigerants. No other refrigerant may be used in
this system. All equipment must be designed to handle
R-410A refrigerant. If unsure about equipment, consult
the equipment manufacturer.
CAUTION:
Do not operate the unit without a filter
or with the grille removed. Damage to the unit or per-
sonal injury may result.
Fig. 1 — 619FNF, FNQ Unit
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
—3— 2'-4-11/32"(720) 1'-9-21/32"(550) ) 5 1 5( " 2 3/ 9 8-' 1 1-7/8"(47) 1'-11-7/16"(595) ) 3 1 8( " 8-' 2 ) 0 6 9( " 4 6/ 1 5- 1-' 3 ) 9 4 ( " 6 1 / 5 1 - 1 2 " (50) ) 4 2( " 6 1/ 5 1 ) 3 5 1( " 6 ) 8 2 1( " 5 2'-8-1/2"(825) ) 8 6 1( " 8/ 5- 6...
—4— Table 4A — 619FNF Physical Data LEGEND *See Table 3 for factory charge and additional field charge requirements. SYSTEM SIZE 018 024 030 036 NOMINAL CAPACITY (Btuh) 17,000 23,600 29,000 36,400 OPERATING WEIGHT (lb) 49 91 95 95 SEER 13 REFRIGERANT* R-410A Control (Cooling) AccuRator Control INDOO...
—5— Table 4B — 619FNQ Physical Data LEGEND *See Table 3 for factory charge and additional field charge requirements. SYSTEM SIZE 018 024 030 036 NOMINAL CAPACITY (Btuh) Heat Pump Cooling 17,900 22,600 29,200 33,400 Heating 16,800 20,800 27,400 32,400 Cooling with Electric Heat 17,000 22,600 29,000 3...