Page 3 - Fig. 2 — Unit Dimensions
—3— 2'-4-11/32"(720) 1'-9-21/32"(550) ) 5 1 5( " 2 3/ 9 8-' 1 1-7/8"(47) 1'-11-7/16"(595) ) 3 1 8( " 8-' 2 ) 0 6 9( " 4 6/ 1 5- 1-' 3 ) 9 4 ( " 6 1 / 5 1 - 1 2 " (50) ) 4 2( " 6 1/ 5 1 ) 3 5 1( " 6 ) 8 2 1( " 5 2'-8-1/2"(825) ) 8 6 1( " 8/ 5- 6...
Page 4 - Table 4A — 619FNF Physical Data
—4— Table 4A — 619FNF Physical Data LEGEND *See Table 3 for factory charge and additional field charge requirements. SYSTEM SIZE 018 024 030 036 NOMINAL CAPACITY (Btuh) 17,000 23,600 29,000 36,400 OPERATING WEIGHT (lb) 49 91 95 95 SEER 13 REFRIGERANT* R-410A Control (Cooling) AccuRator Control INDOO...
Page 5 - Table 4B — 619FNQ Physical Data
—5— Table 4B — 619FNQ Physical Data LEGEND *See Table 3 for factory charge and additional field charge requirements. SYSTEM SIZE 018 024 030 036 NOMINAL CAPACITY (Btuh) Heat Pump Cooling 17,900 22,600 29,200 33,400 Heating 16,800 20,800 27,400 32,400 Cooling with Electric Heat 17,000 22,600 29,000 3...
Page 6 - II. STEP 2 — LOCATING AND MOUNTING THE UNIT; Max. 2 louvers closed; Fig. 3 — Louver Positioning
—6— II. STEP 2 — LOCATING AND MOUNTING THE UNIT A. Locating the Unit Install the unit as centrally as possible in the room. The air- flow direction can be controlled by the remote control (where used) or automatically, according to the unit operating mode (cooling or heating). Controlling the airflo...
Page 8 - A. Locating the Room Controller; Do not; Frame support brackets; Fig. 10 — Condensate Drain Pipe; A AIR B; Fig. 13 — Gasket Location
—8— III. STEP 3 — LOCATING AND MOUNTING THE ROOMCONTROLLER A. Locating the Room Controller See Fig. 14 for room controller dimensions. If the air sensor in the room controller is going to be used, the room controller should be located by considering the following: • Position controller with a minimu...
Page 9 - Fig. 14 — Room Controller Dimensions; Fig. 16 — Locating the Connection Cable; Connection Cable; Fig. 17 — Connecting the Room Controller; Mounting screws; Fig. 15 — Mounting the Room Controller
—9— B. Mounting the Room Controller (Fig. 15-17) Unscrew the side fixing screw. Open the room controller rear mounting base to expose the mounting holes. The base can be removed to simplify mounting (snap apart carefully at hinge to separate mounting base from the rest of the room controller). Route...
Page 10 - Adjustable wrench or torque wrench
—10— IV. STEP 4 — COMPLETE REFRIGERANT PIPINGCONNECTIONS IMPORTANT: During unit installation make the refrigerant connections first and then the electrical connections. If the unit is uninstalled, disconnect the electrical cables first and then the refrigerant connections. Refer to the outdoor unit ...
Page 15 - Fig. 24 — 619FNF/538ENF Cooling Only System Wiring Diagram
—15— E T T E S S A C L A B O L G 619FNF R E S N E D N O C R O O D T U O 538ENF NOTE 6 NOTE 5 NOTE 4 Y A L P S I D R I A - M T L I O C - M T " D " R A L U D O M B C P 1 L O R T N O C R E P P O C E R A B T C E N N O C S I D T I N U O T ) D E D I V O R P E L B A C E S U (D N G . P I U Q E V 0 3...
Page 18 - INTERNAL CONTROL PANEL; Fig. 27 — Internal Control Panel
—18— INTERNAL CONTROL PANEL 619FNF018 CapacitorGMC boardElectric heater board(only on models with electric heater)TransformerHoles for fixing panel in positionEmergency push-button Fan connectorLED/RECEIVER connector Float connectorPump connectorLouver connector C P C G C A C V C LR INTERNAL CONTROL...
Page 19 - Diagram 1; REMOTE
—19— C. Wiring the Room Controller The room controller is capable of controlling from 1 to 6 fan coil units. The total run length of the wire connecting the room controller to the fan coil units should be kept to under 500 feet. Wire the room controller to the unit using daisy chain wiring. See Fig....
Page 20 - Air intake grille; Unit; Ø A; Fig. 30 — Installation Options; Supply air duct to adjacent room
—20— 4.72” (120) Ø A B Ø A Ø C Duct connection flangeClip1/4" (6 mm) neoprene gasketInsulated flexible ductFresh air intakeConditioned air supply to anadjacent roomPolystyrene partitionBaffle (619FNF018 only)Frame WallUndercut door Wall-fitted grilleDoor-fitted grille Air intake grille Unit 619F...
Page 21 - Cooling Only Remote; S with Swing Louver Icon; Represents the swing louver; A with Auto Louver Icon; Represents the auto louver; up
—21— III. ROOM CONTROLLER CONFIGURATION SETUP To configure the room controller, press the Mode button for 5 seconds. After 5 seconds, “10” will appear. This indicates that the user is setting the first software configuration item. To display the value of configuration item 10, press the Mode button ...
Page 22 - ITEM; push; Or; Fig. 33 — Selecting the Louver Mode
—22— Table 8 — Modular Platform D Unit Configuration Values Only the current value being displayed is transmitted. Once the Fan button is pressed, the room controller will switch to displaying the configuration item number. To move to the next setting, press the Mode button again and the “20” will b...
Page 23 - Table 9 — Fault Codes; CODE
—23— 4. Ensure that the filters and return air grilles have been installed and that the discharge louvers are correctly positioned. SERVICE AND MAINTENANCE Remove unit grille, filter, and condensate pan for cleaning, lubricating, or replacing parts. I. MINIMUM MAINTENANCE 1. Check, clean, or replace...
Page 24 - Fig. 35 — Warning Lamps and Emergency Button
Copyright 2006 Bryant Heating & Cooling Systems Printed in U.S.A. CATALOG NO. 02-619F0001-II Green LED Red LED Yellow LED Remote control signal receiver Emergency Button Fig. 35 — Warning Lamps and Emergency Button