Bryant 558F.36.1 - Manual

Bryant 558F.36.1

Bryant 558F.36.1 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 15 – Fig. 13 — Motormaster® I Wiring Details; OFC —
  • Page 16 – Outdoor-Fan Contactor; TRAN —; Transformer
  • Page 17 – CLO —; Fig. 17 — Wiring Connections for Solid-State
  • Page 18 – LEGEND; OAT —; Outdoor-Air Thermostat
  • Page 19 – OR; Fig. 21 — Wiring Diagram for Power Exhaust System
Loading the manual

Cancels: New

WD 558F.36.1

11/15/00

DIAGRAM INDEX

LEGEND

UNIT LABEL DIAGRAM

Unit 558F

Voltage-Phase-Hertz

Type

Label Diagram

Figure No.

036,048

208/230-1-60

Schematic/Component Arrangement

50DK508524

1

208/230-3-60

Schematic/Component Arrangement

50DK508526

2

460-3-60

Schematic/Component Arrangement

50DK508529

3

575-3-60

Schematic/Component Arrangement

50DK508531

4

060

208/230-1-60

Schematic/Component Arrangement

50DK508525

5

208/230-3-60

Schematic/Component Arrangement

50DK508527

6

460-3-60

Schematic/Component Arrangement

50DK508530

7

575-3-60

Schematic/Component Arrangement

50DK508532

8

072

208/230-3-60, 460-3-60

Schematic/Component Arrangement

50DK508528

9

575-3-60

Schematic/Component Arrangement

50DK508533

10

090-150

208/230-3-60, 460-3-60

Schematic/Component Arrangement

50DK508793

11

575-3-60

Schematic/Component Arrangement

50DK508794

12

ACCESSORY WIRING

Description

Unit Size

Fig. No.

Motormaster® I Control

036-150

13

Motormaster II Control

036-072

14

090-150

15

Time Guard® II Device

036-150

16

Solid-State Enthalpy Control

036-150

17

Differential Enthalpy Control

036-150

18

EconoMi$er

036-072

19

EconoMi$er Sensor Wiring

036-150

20

Power Exhaust

036-072

21

wiring diagrams

SINGLE PACKAGE ROOFTOP
ELECTRIC COOLING
UNITS

558F

036-150

3 to 12

1

/

2

Tons

AHA

Adjustable Heat Anticipator

AWG

American Wire Gage

C

Contactor, Compressor

CAP.

Capacitor

CB

Circuit Breaker

CC

Cooling Compensator

COMP —

Compressor Motor

D

Diode

EC

Enthalpy Control

ECON —

Economizer

EPS

Emergency Power Supply
(Nine-Volt Battery)

EQUIP —

Equipment

ER

Economizer Relay

FPT

Freeze-Up Protection Thermostat

FU

Fuse

GND

Ground

HC

Heater Contactor (Strip Heat)

HPS

High-Pressure Switch

IFC

Indoor-Fan Contactor

IFM

Indoor-Fan Motor

IFMOVL —

Indoor-Fan Motor Overload

TDR

Time-Delay Relay

TH

Thermostat, Heating

TRAN —

Transformer

Field Splice

Marked Wire

Terminal (Marked)

Terminal (Unmarked)

Terminal Block

Splice

Splice (Marked)
Factory Wiring
Field Control Wiring
Field Power Wiring
Accessory or Optional Wiring
To indicate common potential only.
Not to represent wiring.

IFR

Indoor-Fan Relay

LPS

Low-Pressure Switch

LSM

Limit Switch (Manual Reset)

MTR

Motor

OAT

Outdoor-Air Thermostat

OFC

Outdoor-Fan Contactor

OFM

Outdoor-Fan Motor

OLR

Overload Relay

P

Plug

PL

Plug Assembly

QT

Quadruple Terminal

R

Relay

SAT

Supply-Air Thermostat

SEN

Sensor

ST

Start Thermistor

SW1

Switch Fully Open

SW2

Switch Fully Closed

SW3

Switch Minimum Vent Position

SW4

Switch Maximum Vent Position

TB

Terminal Block

TC

Thermostat, Cooling

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 15 - Fig. 13 — Motormaster® I Wiring Details; OFC —

—15— Fig. 13 — Motormaster® I Wiring Details Fig. 14 — Motormaster II Wiring Schematic; 558F036-072 558F090-150 558F036-072 LEGEND C — Contactor LEGEND NOTE: Motormaster II transformer is wired for 460-v supply; it must be rewired for 208/230-v application.Be sure to insulate unused tap. Refer to co...

Page 16 - Outdoor-Fan Contactor; TRAN —; Transformer

—16— LEGEND *The Motormaster II head pressure controller is equipped with an alternate operating mode. When this mode is selected, the controller shifts the fan cycle sequence to effectively raise the averagecondensing temperature approximately 20 F higher than the standard operating mode. In thisal...

Page 17 - CLO —; Fig. 17 — Wiring Connections for Solid-State

—17— 620 ohmJUMPER } 24 VAC SUPPLY FROMECONOMIZER CONTROLSECTION (RED TO TR,BRN TO TR1) TO SENSOR MOUNTEDON BACK OF CONTROL } GRAY WIRE FROMECONOMIZER HARNESS RED WIRE FROMECONOMIZER SWITCH 3(NORMALLY CLOSED) TR TR1 SO + + SR 2 3 1 LED A B CD LED A B C D TR TR1 SO SR 2 3 1 + + S + (HH57AC078 SENSOR)...

Other Bryant Models

All Bryant Other