Bryant 580D - Manual

Bryant 580D

Bryant 580D – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
Page: / 72

Table of Contents:

  • Page 2 – The units can be easily converted from a vertical to a hori-
  • Page 3 – TABLE OF CONTENTS; Page
  • Page 4 – MODEL NUMBER NOMENCLATURE; tion cutout switches.
  • Page 6 – ARI* CAPACITY RATINGS; *Air Conditioning and Refrigeration Institute.
  • Page 9 – Cleanable
  • Page 13 – POWER EXHAUST; or resetting thermostat.
  • Page 14 – OPTIONS AND ACCESSORIES; and option package information.; HEAD PRESSURE CONTROL
  • Page 16 – ACCUSENSOR III
  • Page 21 – ACCESSORY DIMENSIONS; *Either connector package available for either roof curb.
  • Page 23 – Horizontal and Vertical Roof Curbs and Horizontal Adapter; LEGEND; CURB; UNIT LEVELING TOLERANCES*
  • Page 24 – Horizontal Supply/Return Adapter Installation; ACCESSORY; Power Exhaust
  • Page 25 – SELECTION PROCEDURE (with 579F180 example)
  • Page 26 – Standard Ratings
  • Page 30 – Use formula
  • Page 32 – FAN PERFORMANCE — 580D036-150 VERTICAL DISCHARGE UNITS (cont)
  • Page 34 – page 52 for accessory/FIOP static pressure information.
  • Page 40 – FAN PERFORMANCE — 580D036-150 HORIZONTAL DISCHARGE UNITS (cont)
  • Page 48 – Deduct 0.2 in. wg static pressure for high heat units at or above
  • Page 50 – Deduct 0.3 in. wg static pressure for high heat units at or above
  • Page 51 – ries may be used to provide horizontal supply/return.
  • Page 53 – †Orifices available through your local distributor.
  • Page 54 – EVAPORATOR-FAN MOTOR EFFICIENCY; *As the height above sea level increases, there is less oxygen per; ALTITUDE DERATING FACTOR* —
  • Page 55 – EVAPORATOR-FAN MOTOR PERFORMANCE
  • Page 58 – NEC — National Electrical Code
  • Page 62 – LEGEND FOR TYPICAL WIRING SCHEMATICS
  • Page 63 – CONTROLS; OPERATING SEQUENCE
  • Page 65 – APPLICATION DATA; SERVICE
  • Page 66 – are obtained from field-supplied
  • Page 72 – b. Capable of comparing heat content (temperature
Loading the manual

Standard-Efficiency Rooftop Units with:
• Exclusive integrated gas control board with diagnostics
• Alumagard™ heat exchanger coating
• Induced-draft fan for gas combustion
• Tubular, dimpled heat exchangers
• Pre-painted galvanized steel cabinet for long life and quality

appearance

• Commercial strength baserails with built-in rigging capability
• Convertible design for horizontal supply/return
• Non-corrosive, sloped condensate drain pan, meets ASHRAE

62-89 (IAQ)

• Two-inch return-air filters
• A wide assortment of factory-installed options available, in-

cluding high static drives that provide additional performance
range

FEATURES/BENEFITS

Every compact one-piece unit arrives fully assembled, charged,
tested, and ready to run.

INTEGRATED GAS UNIT CONTROLLER (IGC) (All Models)
All ignition components are contained in the compact IGC
which is easily accessible for servicing. The IGC control board,
designed and manufactured exclusively for Bryant rooftop units,
provides built-in diagnostic capability. An LED (light-emitting di-
ode) simplifies troubleshooting by providing visual fault notifica-
tion and system status confirmation.

The IGC also contains an exclusive anti-cycle protection for gas
heat operation. After 4 continuous cycles on the unit high-
temperature limit switch, the gas heat operation is disabled, and
an error code is issued. This feature greatly improves reliability
of the rooftop unit.

580D036-072

580D090-150

579F180,216

579F240,300

COMMERCIAL
SINGLE PACKAGE ROOFTOP
GAS HEATING/ELECTRIC COOLING UNITS

Model 579F/580D

Sizes 036-300

3 to 25 Tons

Form No. PDS 580D.36.8

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - The units can be easily converted from a vertical to a hori-

The IGC also contains burner control logic for accurate and dependable gas ignition. The LED is visible without removingthe unit control box access panel. This LED fault-notificationsystem reduces service person troubleshooting time and mini-mizes service costs. The IGC also maximizes heating effici...

Page 3 - TABLE OF CONTENTS; Page

PROVEN COMPRESSOR RELIABILITY — Design techniquesfeature computer programmed balance between compressor,condenser, and evaporator. Hermetic (036-150 units) and semi-hermetic (180-300 units) compressors with suction anddischarge service valves are equipped with compressor over-current and overtempera...

Page 4 - MODEL NUMBER NOMENCLATURE; tion cutout switches.

MODEL NUMBER NOMENCLATURE *Contains high pressure, (loss-of-charge) low-pressure, and freeze protec- tion cutout switches. NOTE: The example model number 580DEV090180CB designates a 7 1 ⁄ 2 ton 460-3-60 volt gas/electric rooftop unit with 180,000 Btuh natural gasheat, Durablade economizer, and alter...