Page 2 - DIMENSIONS
—2— DIMENSIONS A SQ AIR IN AIR IN 3 / 8 -IN. DIA TIEDO WN KNOCK OUTS (2) PLA CES H G F E L K J AIR IN M N AIR DISCHARGE AIR IN AIR DISCHARGE NO TES: 1. ALLO W 30" CLEARANCE T O SER VICE SIDE OF UNIT , 48" ABO VE UNIT , 6" ON ONE SIDE, 12" ON REMAINING SIDE, AND 24" BETWEEN UNITS ...
Page 3 - RECOMMENDED TUBE DIAMETERS; CERTIFICATION APPLIES ONLY
—3— RECOMMENDED TUBE DIAMETERS * For tube sets greater than 50 ft, consult Residential Split System Application Guideline and Service Manual. CHECK-FLO-RATER® PISTON * Piston listed is for any approved non-capillary tube coil combination. Piston is shipped with outdoor unit and must be installed in ...
Page 4 - SPECIFICATIONS
—4— SPECIFICATIONS See notes on page 6. UNIT SIZE-SERIES 024-A 030-A/A 036-A/A Operating Weight (Lb) 143 138 156 ELECTRICAL Unit Volts—Hertz—Phase 208/230—60—1 208/230—60—1/208/230—60—3 208/230—60—1/208/230—60—3 Operating Voltage Range* 187—253 187—253/197—253 187—253/197—253 Compressor— Rated Load ...
Page 5 - SPECIFICATIONS Continued
—5— SPECIFICATIONS Continued UNIT SIZE-SERIES 042-A/A 048-A/A 060-A/A Operating Weight (Lb) 197 203 238 ELECTRICAL Unit Volts—Hertz—Phase 208/230—60—1/208/230—60—3 Operating Voltage Range* 187—253/197—253 Compressor—Rated Load Amps 18.6/13.5 20.5/14.7 27.6/18.1 Locked Rotor Amps 105.0/77.0 109.0/91....
Page 8 - COMBINATION RATINGS
—8— COMBINATION RATINGS See notes on page 13. UNIT SIZE-SERIES INDOOR MODEL TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT SEER EER Standard Rating Bryant Gas Furnace or Accessory TDR† Accessory TXV‡ 024-A CK5A/CK5BA030* 23,000 NONE — 12.00 12.00 10.05 CC5A/CD5AA024 23,000 NONE — 11.70 11.70 9.90 CC...
Page 9 - COMBINATION RATINGS Continued
—9— COMBINATION RATINGS Continued See notes on page 13. UNIT SIZE-SERIES INDOOR MODEL TOT. CAP. BTUH FACTORY- SUPPLIED ENHANCE- MENT SEER EER Standard Rating Bryant Gas Furnace or Accessory TDR† Accessory TXV‡ 030-A COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE CC5A/CD5AA030 27,800 TDR 12.50 — 12....
Page 13 - EER; TXV
—13— * Tested combination. † In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with T...
Page 14 - DETAILED COOLING CAPACITIES*
—14— DETAILED COOLING CAPACITIES* See notes on page 19. EVAP AIR CONDENSER ENTERING AIR TEMPERATURES °F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† Total Sys Kw** Capacity MBtuh† Total Sys Kw** Capacity MBtuh† Total Sys Kw** Capacity MBtuh† Total Sys Kw** Capacity MBtuh† Total Sys Kw** Capacity MBt...
Page 15 - DETAILED COOLING CAPACITIES* Continued
—15— DETAILED COOLING CAPACITIES* Continued See notes on page 19. EVAP AIR CONDENSER ENTERING AIR TEMPERATURES °F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† Total Sys Kw** Capacity MBtuh† Total Sys Kw** Capacity MBtuh† Total Sys Kw** Capacity MBtuh† Total Sys Kw** Capacity MBtuh† Total Sys Kw** Ca...
Page 20 - CONDENSER ONLY RATINGS*; SST
—20— CONDENSER ONLY RATINGS* See notes on page 21. SST °F CONDENSER ENTERING AIR TEMPERATURES °F 55 65 75 85 95 105 115 125 533AN024-A 30 TCG 23.3 22.1 20.8 19.6 18.3 17.0 15.7 14.4 SDT 76.9 86.8 96.6 107. 117. 127. 136. 146. KW 1.20 1.37 1.55 1.76 1.98 2.22 2.48 2.74 35 TCG 25.6 24.3 22.9 21.5 20.2...
Page 21 - CONDENSER ONLY RATINGS* Continued
—21— CONDENSER ONLY RATINGS* Continued * ARI listing applies only to systems shown in Ratings and Performance table.KW — Total Power (Kw)SDT — Saturated Temperature Leaving Compressor (°F)SST — Saturated Temperature Entering Compressor (°F)TCG — Gross Cooling Capacity (1000 Btuh). SST °F CONDENSER E...
Page 22 - SYSTEM DESIGN SUMMARY; Do not apply capillary tube indoor coils to these units.
—22— SYSTEM DESIGN SUMMARY 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C).3. Maximum outdoor operating a...
Page 24 - GUIDE SPECIFICATIONS; GENERAL
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: NEW © 2000 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN 46231 — 24 — PRINTED IN U.S.A. Catalog No. 5253-300 2-00 GUIDE SPECIFICATIONS GENERAL System Des...