Page 2 - Johnson Controls Unitary Products; Physical and Electrical Data; DIMENSIONS
271457-YTG-B-0908 2 Johnson Controls Unitary Products All dimensions are in inches. They are subject to change with-out notice. Certified dimensions will be provided upon request. Physical and Electrical Data MODEL YZB1811 YZB02411 YZB03011 YZB03611 YZB04211 YZB04811 YZB06012 Unit Supply Voltage 208...
Page 3 - Additional R-410A Charge / TXV Size for Various Matched Systems; Outdoor Unit
271457-YTG-B-0908 Johnson Controls Unitary Products 3 * Does not achieve 13 SEER with PSC furnaces. For ratings, see technical guide or visit www.aridirectory.org/ari/unitary.html. PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest ev...
Page 4 - COOLING CAPACITY - With Air Handler Coils
271457-YTG-B-0908 4 Johnson Controls Unitary Products — = Not applicable. Go to www.ari.org/aridirectory for the latest additional matches. COOLING CAPACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL W RATED CFM NET MBH SEER EER TOTAL SENS. 1 PH 13 SEER HP WITH MA YZB...
Page 5 - COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
271457-YTG-B-0908 Johnson Controls Unitary Products 5 COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils UNIT MODEL FURNACE COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RATED CFM NET MBH SEER 1 EER TOTAL SENS. YZB01811 450 750 14,17 FC/MC/PC/UC18 600 18.0 13.2 13.00 11.00 14 HC18 ...
Page 6 - COOLING CAPACITY - YZB01811 With Variable Speed Furnaces
271457-YTG-B-0908 6 Johnson Controls Unitary Products COOLING CAPACITY - YZB01811 With Variable Speed Furnaces VARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RATED CFM NET MBH SEER EER TOTAL SENS. 1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES 2 PV8*A12 FC/MC/PC18A 14 600 18.4 12.9 14.00 11.50 PV...
Page 7 - COOLING CAPACITY - YZB02411With Variable Speed Furnaces
271457-YTG-B-0908 Johnson Controls Unitary Products 7 COOLING CAPACITY - YZB02411With Variable Speed Furnaces VARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RATED CFM NET MBH SEER EER TOTAL SENS. 1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES 2 PV8*A12 FC/MC/PC24A 14 750 23.0 16.1 13.50 11.00 PV9...
Page 8 - COOLING CAPACITY - YZB03011With Variable Speed Furnaces
271457-YTG-B-0908 8 Johnson Controls Unitary Products COOLING CAPACITY - YZB03011With Variable Speed Furnaces VARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RATED CFM NET MBH SEER EER TOTAL SENS. 1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES 2 PV8*A12 FC/MC/PC36A 14 1050 30.0 21.0 13.25 11.00 PV...
Page 9 - COOLING CAPACITY - YZB03611With Variable Speed Furnaces
271457-YTG-B-0908 Johnson Controls Unitary Products 9 G*9V*B12 HD36 17 985 29.2 20.8 13.70 11.70 G*9V*C16 HD36 21 1005 29.2 20.8 13.90 11.90 G*9V*C20 HD36 21 1045 29.2 20.8 13.80 11.70 G*9V*A12 UC30A 14 1000 29.4 21.0 13.80 11.60 G*9V*A12 UC36A 14 1000 29.4 21.0 13.80 11.60 G*9V*B12 UC36B 17 985 29....
Page 11 - COOLING CAPACITY - YZB04211With Variable Speed Furnaces
271457-YTG-B-0908 Johnson Controls Unitary Products 11 COOLING CAPACITY - YZB04211With Variable Speed Furnaces VARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RATED CFM NET MBH SEER EER TOTAL SENS. 1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES 2 PV8*C16 FC/MC/PC48C 21 1400 41.0 28.7 13.25 11.00 P...
Page 12 - COOLING CAPACITY - YZB04811With Variable Speed Furnaces
271457-YTG-B-0908 12 Johnson Controls Unitary Products COOLING CAPACITY - YZB04811With Variable Speed Furnaces VARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RATED CFM NET MBH SEER EER TOTAL SENS. 1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES 2 P(C,V)9*D20 FC/MC/PC60D 24 1600 46.0 32.2 13.25 11....
Page 13 - HEATING PERFORMANCE - With Air Handler
271457-YTG-B-0908 Johnson Controls Unitary Products 13 CP equals MBH output divided by (total KW input x 3.412).HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.— = ...
Page 14 - HEATING PERFORMANCE - Upflow Furnace Coils; UNIT
271457-YTG-B-0908 14 Johnson Controls Unitary Products CP equals MBH output divided by (total KW input x 3.412).HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.— = ...
Page 15 - HEATING CAPACITY - YZB01811With Variable Speed Furnaces
271457-YTG-B-0908 Johnson Controls Unitary Products 15 CP equals MBH output divided by (total KW input x 3.412).HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. HEA...
Page 16 - HEATING CAPACITY - YZB02411With Variable Speed Furnaces
271457-YTG-B-0908 16 Johnson Controls Unitary Products CP equals MBH output divided by (total KW input x 3.412).HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. HEA...
Page 17 - HEATING CAPACITY - YZB03011With Variable Speed Furnaces
271457-YTG-B-0908 Johnson Controls Unitary Products 17 HEATING CAPACITY - YZB03011With Variable Speed Furnaces VARIABLE SPEED FURNACE COIL 1 MODEL ARI HEATING 2 47 ° F 17 ° F HSPF MBH COP KW MBH COP KW STD 1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES PV8*A12 FC/MC/PC36A 29.4 3.44 2.50 18.3 2.28 2.35...
Page 18 - HEATING CAPACITY - YZB03611With Variable Speed Furnaces
271457-YTG-B-0908 18 Johnson Controls Unitary Products CP equals MBH output divided by (total KW input x 3.412).HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. G*9...
Page 20 - HEATING CAPACITY - YZB04211With Variable Speed Furnaces
271457-YTG-B-0908 20 Johnson Controls Unitary Products CP equals MBH output divided by (total KW input x 3.412).HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. HEA...
Page 21 - HEATING CAPACITY - YZB04811With Variable Speed Furnaces
271457-YTG-B-0908 Johnson Controls Unitary Products 21 CP equals MBH output divided by (total KW input x 3.412).HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. HEA...
Page 22 - COLOR GRILLES; UNIT MODEL; CHOICE OF SEVERAL COLOR COIL GRILLES TO
271457-YTG-B-0908 22 Johnson Controls Unitary Products ACCESSORIES* Hard Start Kit (024-31994-000, 024-31995-000) - Provides increased starting torque for areas with low voltage. TXV Kits - 1TV09 series thermal expansion valves precisely meter refrigerant for optimum performance. Compressor Discharg...
Page 23 - COOLING PERFORMANCE DATA; AIR CONDITIONER MODEL NO.
271457-YTG-B-0908 Johnson Controls Unitary Products 23 Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature ...
Page 24 - OUTDOOR UNIT MODEL NO.
271457-YTG-B-0908 24 Johnson Controls Unitary Products Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature ...
Page 26 - Coil
271457-YTG-B-0908 26 Johnson Controls Unitary Products Variable Speed Furnace Coil T.C. S.C. KW PV8*A12 FC/MC/PC36A 1.02 0.98 1.01 PV9*A12 FC/MC/PC36A 1.01 0.97 1.01 PV8*B16 FC/MC/PC36B 1.02 0.98 1.03 P(C,V)9*B12 FC/MC/PC36B 1.01 0.97 1.01 PV8*C16 FC/MC/PC36C 1.02 0.98 1.03 P(C,V)9*C16 FC/MC/PC36C 1...
Page 32 - HEATING PERFORMANCE DATA
271457-YTG-B-0908 32 Johnson Controls Unitary Products Multipliers for determining the performance with other indoor sections. HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. YZB01811 INDOOR COIL MODEL NO. FC/MC/PC/UC18 AIR TEMP. ENTERING OUTDOOR UNIT AIR TEMP. ENTERING INDOOR COIL ID CFM 450 600 75...