York YWC

York YWC – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – TABLE OF CONTENTS; • IOM for YSHW, YSHX
  • Page 3 – INSTALLATION; RECEIVING; See Fig 7 for unit details and dimensions.; MODEL NUMBER; TABLE 1 – DRYWALL OPENINGS
  • Page 4 – WIRING; NO AQUASTAT LOCKOUT
  • Page 5 – PIPING
  • Page 6 – DRAIN PIPING; This area is provided for the supply and; if; they are brought up from below the pan.; All; piping must be well insulated to prevent sweating.
  • Page 7 – YVS; BACK
  • Page 8 – TOP; GENERAL DIMENSIONS IN INCHES
  • Page 10 – MODEL DRYWALL CUTOUT DIMENSIONS; FIG. 10 - YWC FAN COIL INSTALLATION LOCATION DIMENSIONS
  • Page 11 – INSTALL CHECKLIST
  • Page 12 – MAINTENANCE; MOTOR; it; COIL
Loading the manual

INSTALLATION, OPERATION, & MAINTENANCE

FAN COIL

AIR CONDITIONERS

Supersedes: Form 115.20-NOM3 (105) Form 115.20-NOM3 (1006)

***** WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER *****

Altering the product or replacing parts with non authorized factory parts voids all warranty or

implied warranty and may result in adverse operational performance and/or a possible hazardous

safety condition to service personnel and occupants. Company employees and/or contractors are

not authorized to waive this warning.

Notes:

1. 2-Pipe units have one water coil. 4-Pipe units have two water coils.
2. Changeover is used to select heating or cooling mode.
3. YORK International does not recommend “fan cycle” applications for cooling on unit mounted thermostats.
4. For proper operation, control valve must be normally closed.
5. Aquastats provided where required.

MODEL YVC -Vertical Concealed Model

The

YVC

model fan

coil is

designed to be furred into the

wall where the supply and return or both are connected

to short runs of ductwork. These units are often used

for perimeter heating and cooling

of offices,

corridors,

hospitals, apartments, hotels, and other multi-room

buildings.

MODEL YVS

I

YVF -Vertical Cabinet Models YVS

(Slant Top), YVF (Flat Top)

The

YVS

I

YVF

model fan

coils

have the addition

of

an

attractive, painted cabinet to blend with any decor. These

units will have heavy-duty stamped face louvered grilles

(Style A), plastic discharge grilles (Style A), or metal

grilles (Style B). These units are typically installed in

plain sight, under windows

or

against walls in schools,

hospitals, office buildings, and other institutions.

MODEL YWC -Vertical Recessed Wall Model

The

YWC

model fan

coil

is designed to be recessed

into the wall. These units are engineered to be quiet and

designed

to

be easy to install and service. These units

are ideal for perimeter heating and cooling in hotels,

apartments, hospitals, public

office

buildings,

offices,

corridors, and other multi-room buildings. This unit

comes standard with

a

decorative wall panel for front

supply and return air.

00563VIPa

00803VIPa

YVC

YVF/YVS

YWC

00771VIPa

L23953Y 1006

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS; • IOM for YSHW, YSHX

YORK INTERNATIONAL 2 FORM 115.20-NOM3 (1006) TABLE OF CONTENTS FIG. 1 – VERTICAL UNITS ONLY - YVC, YWC, YVF, YVS AIR FLOW FIG. 1 – VERTICAL UNITS ONLY - YVC, YWC, YVF, YVS AIR FLOW Reference Documents: • IOM for YH (Horizontal Units) Form 115.20-NOM3 (Latest) • IOM for YSHW, YSHX Form115.22-NOM5 (La...

Page 3 - INSTALLATION; RECEIVING; See Fig 7 for unit details and dimensions.; MODEL NUMBER; TABLE 1 – DRYWALL OPENINGS

3 YORK INTERNATIONAL INSTALLATION FORM 115.20-NOM3 (1006) RECEIVING Material in this shipment has been inspected at the factory and released to the transportation agency in good condition. When received, a visual inspection of all cartons should be made immediately. Any evidence of rough handling or...

Page 4 - WIRING; NO AQUASTAT LOCKOUT

YORK INTERNATIONAL 4 FORM 115.20-NOM3 (1006) INSTALLATION WIRING All wiring must comply with the local and national code requirements. Units are provided with wiring diagrams and nameplate data to provide information required for necessary field wiring. For power wiring a control box is provided on t...