- Page 2 – TABLE OF CONTENTS; • IOM for YSHW, YSHX
- Page 3 – INSTALLATION; RECEIVING; See Fig 7 for unit details and dimensions.; MODEL NUMBER; TABLE 1 – DRYWALL OPENINGS
- Page 4 – WIRING; NO AQUASTAT LOCKOUT
- Page 5 – PIPING
- Page 6 – DRAIN PIPING; This area is provided for the supply and; if; they are brought up from below the pan.; All; piping must be well insulated to prevent sweating.
- Page 7 – YVS; BACK
- Page 8 – TOP; GENERAL DIMENSIONS IN INCHES
- Page 10 – MODEL DRYWALL CUTOUT DIMENSIONS; FIG. 10 - YWC FAN COIL INSTALLATION LOCATION DIMENSIONS
- Page 11 – INSTALL CHECKLIST
- Page 12 – MAINTENANCE; MOTOR; it; COIL
INSTALLATION, OPERATION, & MAINTENANCE
FAN COIL
AIR CONDITIONERS
Supersedes: Form 115.20-NOM3 (105) Form 115.20-NOM3 (1006)
***** WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER *****
Altering the product or replacing parts with non authorized factory parts voids all warranty or
implied warranty and may result in adverse operational performance and/or a possible hazardous
safety condition to service personnel and occupants. Company employees and/or contractors are
not authorized to waive this warning.
Notes:
1. 2-Pipe units have one water coil. 4-Pipe units have two water coils.
2. Changeover is used to select heating or cooling mode.
3. YORK International does not recommend “fan cycle” applications for cooling on unit mounted thermostats.
4. For proper operation, control valve must be normally closed.
5. Aquastats provided where required.
MODEL YVC -Vertical Concealed Model
The
YVC
model fan
coil is
designed to be furred into the
wall where the supply and return or both are connected
to short runs of ductwork. These units are often used
for perimeter heating and cooling
of offices,
corridors,
hospitals, apartments, hotels, and other multi-room
buildings.
MODEL YVS
I
YVF -Vertical Cabinet Models YVS
(Slant Top), YVF (Flat Top)
The
YVS
I
YVF
model fan
coils
have the addition
of
an
attractive, painted cabinet to blend with any decor. These
units will have heavy-duty stamped face louvered grilles
(Style A), plastic discharge grilles (Style A), or metal
grilles (Style B). These units are typically installed in
plain sight, under windows
or
against walls in schools,
hospitals, office buildings, and other institutions.
MODEL YWC -Vertical Recessed Wall Model
The
YWC
model fan
coil
is designed to be recessed
into the wall. These units are engineered to be quiet and
designed
to
be easy to install and service. These units
are ideal for perimeter heating and cooling in hotels,
apartments, hospitals, public
office
buildings,
offices,
corridors, and other multi-room buildings. This unit
comes standard with
a
decorative wall panel for front
supply and return air.
00563VIPa
00803VIPa
YVC
YVF/YVS
YWC
00771VIPa
L23953Y 1006
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
YORK INTERNATIONAL 2 FORM 115.20-NOM3 (1006) TABLE OF CONTENTS FIG. 1 – VERTICAL UNITS ONLY - YVC, YWC, YVF, YVS AIR FLOW FIG. 1 – VERTICAL UNITS ONLY - YVC, YWC, YVF, YVS AIR FLOW Reference Documents: • IOM for YH (Horizontal Units) Form 115.20-NOM3 (Latest) • IOM for YSHW, YSHX Form115.22-NOM5 (La...
3 YORK INTERNATIONAL INSTALLATION FORM 115.20-NOM3 (1006) RECEIVING Material in this shipment has been inspected at the factory and released to the transportation agency in good condition. When received, a visual inspection of all cartons should be made immediately. Any evidence of rough handling or...
YORK INTERNATIONAL 4 FORM 115.20-NOM3 (1006) INSTALLATION WIRING All wiring must comply with the local and national code requirements. Units are provided with wiring diagrams and nameplate data to provide information required for necessary field wiring. For power wiring a control box is provided on t...