YORK INTERNATIONAL 2 YORK INTERNATIONAL 3 FORM 150.63-EG1 �� � � � � �� � � ������� ���������� ���� ���������� ���� �������� ������� �������� ����������������������� ����������� ���������������� ������� ���� ������������������������������������������������������� ���� ����� ���������������� ������ �...
YORK INTERNATIONAL 2 YORK INTERNATIONAL 3 FORM 150.63-EG1 YORK Air-Cooled Scroll Condensing Units are the perfect refrigeration com- ponents for all air conditioning applications that use DX central station air handling. They are designed for outdoor (roof or ground level) installation. Each unit in...
YORK INTERNATIONAL 4 YORK INTERNATIONAL 5 FORM 150.63-EG1 Specification GENERAL The 15 - 130 Ton (53 - 457 kW) YCUL Condensing Unit Models are shipped complete from the factory ready for field installation. The unit is pressure-tested, evacuated and given a nitro- gen holding charge and includes an ...
YORK INTERNATIONAL 4 YORK INTERNATIONAL 5 FORM 150.63-EG1 MILLENNIUM CONTROL CENTER All controls are contained in a NEMA 3R/12 (and equivalent to IP55*) cabinet with hinged outer door and includes: Liquid Crystal Display with Light Emitting Diode backlighting for outdoor viewing: Two display lines T...
YORK INTERNATIONAL 6 YORK INTERNATIONAL 7 FORM 150.63-EG1 Options and Accessories POWER OPTIONS: COMPRESSOR POWER CONNECTIONS – Single-point (YCUL0016-0040) or multiple-point (YCUL0046-0130) ter- minal block connection(s) are provided as standard. The following power connections are available as opt...
YORK INTERNATIONAL 8 YORK INTERNATIONAL 9 FORM 150.63-EG1 temperature. (Factory mounted). MOTOR CURRENT MODULE – Capable of monitoring compressor motor current. Provides extra protection against compressor reverse rotation, phase-loss and phase imbalance. Option consists of one module per electrical...
YORK INTERNATIONAL 8 YORK INTERNATIONAL 9 FORM 150.63-EG1 Selection Data The ratings shown on pages 18 through 57 are based on unit operation in a well designed and properly piped system. SELECTION RULES 1. Capabilities are based on Refrigerant 22 or 407C. 2. Ratings may interpolated, but must not b...
YORK INTERNATIONAL 14 YORK INTERNATIONAL 15 FORM 150.63-EG1 TABLE 5 – REFRIGERANT LINE PRESSURE DROPS (METRIC) MODEL NUMBER YCUL SYSTEM NUMBER 1 NOMINAL KW SUCTION LINE LIQUID LINE COPPER TYPE L INCHES O.D. 2 PRESSURE DROP kPa/30.5 m VELOCITY @NOMINAL CAPACITY IN M/S 4 NOMINAL KW UNLOADED COPPER TYP...
YORK INTERNATIONAL 16 YORK INTERNATIONAL 17 FORM 150.63-EG1 NOTES: 1. For lower or higher suction temperature applications, contact your nearest YORK Office for application requirements.2. For operation at temperatures below 25°F (-3.9°C), the optional Low Ambient Kit will need to be installed on th...
YORK INTERNATIONAL 94 YORK INTERNATIONAL 95 FORM 150.63-EG1 YCUL Aluminum Fin Coil Weight Distribution (lbs) A B C D E F G H Total 0016 577 469 554 450 --- --- --- --- 2051 0026 579 470 557 452 --- --- --- --- 2058 0030 697 534 662 507 --- --- --- --- 2401 0036 678 586 634 548 --- --- --- --- 2445 0...
YORK INTERNATIONAL 94 YORK INTERNATIONAL 95 FORM 150.63-EG1 YCUL Copper Fin Coil Weight Distribution (lbs) A B C D E F G H Total 0016 614 470 633 484 --- --- --- --- 2201 0026 616 470 636 486 --- --- --- --- 2208 0030 733 535 742 541 --- --- --- --- 2551 0036 714 586 711 584 --- --- --- --- 2595 004...
YORK INTERNATIONAL 96 YORK INTERNATIONAL 97 FORM 150.63-EG1 Seismic Isolator Selections, VMC Model # AEQM-xxxx YCUL A B C D E F G H 0016 96 96 96 96 --- --- --- --- 0026 96 96 96 96 --- --- --- --- 0030 97 96 97 96 --- --- --- --- 0036 97 96 97 96 --- --- --- --- 0040 98 97 97 96 --- --- --- --- 004...
YORK INTERNATIONAL 100 YORK INTERNATIONAL 101 FORM 150.63-EG1 Isolators 1" DEFLECTION SEISMIC MODEL PART- # COLOR MODEL PART # COLOR CP-1-26 308439-26 PURPLE AEQM-96 301055-96 BLACK CP-1-27 308439-27 ORANGE AEQM-97 301055-97 WHITE CP-1-28 308439-28 GREEN AEQM-98 301055-98 GRAY CP-1-31 308439-31 ...
YORK INTERNATIONAL 100 YORK INTERNATIONAL 101 FORM 150.63-EG1 MODEL # A B C D E F G H J AEQM-97 7 5-1/2 4-1/2 2-1/2 5/8 1/4 7-1/4 5/8 3/8 AEQM-98 7 5-1/2 4-1/2 2-1/2 5/8 1/4 7-1/4 5/8 3/8 AEQM-99 7 5-1/2 4-1/2 2-1/2 5/8 1/4 7-1/4 5/8 3/8 AEQM-1000 8-1/2 6-1/2 6 4-1/2 3/4 3/8 8-3/8 7/8 1/2 AEQM-1300 ...
YORK INTERNATIONAL 102 YORK INTERNATIONAL 103 FORM 150.63-EG1 I . Minimum Circuit Ampacity (MCA) is based on 125% of the rated load amps for the largest motor plus 100% of the rated load amps for all other loads included in the circuit, per N.E.C. Article 430-24. If the optional Factory Mounted Cont...
YORK INTERNATIONAL 102 YORK INTERNATIONAL 103 FORM 150.63-EG1 YCUL0016 - YCUL0040 SINGLE POINT POWER SUPPLY CONNECTIONS (See Fig. 1) (One Field Provided Power Supply to the condensing unit. Field connections to Factory Provided Power Terminal Block (standard), Non-Fused Disconnect Switch (optional) ...
YORK INTERNATIONAL 112 YORK INTERNATIONAL 113 FORM 150.63-EG1 Power Wiring FIG. 2 – SINGLE POINT POWER SUPPLY WIRING Single Point Power Supply Wiring – (0016 - 0090) ������������������������������������������ ������������������������������������������������������������������������������ ����������� ...
YORK INTERNATIONAL 114 YORK INTERNATIONAL 115 FORM 150.63-EG1 FIG. 4 – OPTIONALSINGLE POINT POWER SUPPLY WIRING ������ ��������� ����� ������������ �������������������������� ������ �������������������������� ���������������������������� ���������������������������� ����������������������� ���������...
YORK INTERNATIONAL 116 YORK INTERNATIONAL 117 FORM 150.63-EG1 UNIT LOCATION The YCUL Condensing Units are designed for outdoor installation. When selecting a site for installation, be guided by the following conditions: 1.For outdoor locations of the unit, select a place having an adequate supply of...
YORK INTERNATIONAL 116 YORK INTERNATIONAL 117 FORM 150.63-EG1 Guide Specifications PART 1 – GENERAL 1.01 SCOPE A. The requirements of the General Conditions, Supplementary Conditions, Division 1, and Draw- ings apply to all Work herein. B. Provide Microprocessor controlled, multiple-scroll compresso...
York Manuals
-
York Heating & AIR CONDITIONER
Manual
-
York DFAA
Manual
-
York 480
Manual
-
York D2EB
Manual
-
York CMR00
Manual
-
York DH 036
Manual
-
York DR150
Manual
-
York 122
Manual
-
York YZE024 THRU 060
Manual
-
York YMB-HW
Manual
-
York YHJF18
Manual
-
York Y9USC 09 / 12 / 18 B5R
Manual
-
York CEL20
Manual
-
York YHJD18 THRU 60
Manual
-
York D3HH 024
Manual
-
York 110
Manual
-
York PV8*DH
Manual
-
York Y33
Manual
-
York YWC
Manual
-
York 600
Manual