Page 2 - INSTALLATION; UNIT SIZE; TABLE 1 - NOMINAL AIRFLOWS; • IOM for YSHW, YSHX
YORK INTERNATIONAL 2 FORM 115.20-NOM2 (105) 3 YORK INTERNATIONAL INSTALLATION FORM 115.20-NOM2 (105) TABLE OF CONTENTS UNIT SIZE CFM 3 300 4 400 5 500 6 600 8 800 10 1000 12 1200 13 1300 16 1600 20 2000 TABLE 1 - NOMINAL AIRFLOWS FIG. 1 – DETERMINATION OF RIGHT-HAND / LEFT-HAND REFERENCES LD04775 NO...
Page 3 - RECEIVING
YORK INTERNATIONAL 2 FORM 115.20-NOM2 (105) 3 YORK INTERNATIONAL INSTALLATION FORM 115.20-NOM2 (105) RECEIVING Material in this shipment has been inspected at the factory and released to the transportation agency in good condition. When received, a visual inspection of all cartons should be made imm...
Page 4 - FIG. 2 – HORIZONTAL UNITS - TYPICAL WIRING
INSTALLATION 4 YORK INTERNATIONAL FORM 115.20-NOM2 (105) 5 YORK INTERNATIONAL INSTALLATION FORM 115.20-NOM2 (105) FIG. 2 – HORIZONTAL UNITS - TYPICAL WIRING ����� � � � � �� � �� � � � � � � � �� � � ����������� �������� ������������ � � � � �� � �� � � � ���� � � � ����� �������� ����� ������ �� � ...
Page 6 - PRECAUTIONS
INSTALLATION 6 YORK INTERNATIONAL FORM 115.20-NOM2 (105) 7 YORK INTERNATIONAL INSTALLATION FORM 115.20-NOM2 (105) Prior to connecting to the fan coil, all external piping must be purged of debris. When connecting piping or valve kits to fan coil units, do not bend or reposition the coil header tubin...
Page 7 - -Way Motorized Valve Assemblies
INSTALLATION 6 YORK INTERNATIONAL FORM 115.20-NOM2 (105) 7 YORK INTERNATIONAL INSTALLATION FORM 115.20-NOM2 (105) VALVE CLUSTER 2-Way Motorized Valve Assemblies 1. The motorized valve assembly should be attached to the supply header, which is the connection nearest the air outlet flange on the unit....
Page 8 - Coil Connections (looking with airflow,; MODEL; Ceiling Concealed Model – MODEL YHBC
INSTALLATION 8 YORK INTERNATIONAL FORM 115.20-NOM2 (105) 9 YORK INTERNATIONAL INSTALLATION FORM 115.20-NOM2 (105) NOM. CFM (100's) 3, 4, 5, 6, 8, 10 or 13 Unit Style Y - Ceiling Concealed YP - with return plenum & filter YR - recessed w/telescoping panel YC - cabinet exposed Coil Configuration 3...
Page 9 - PHYSICAL DIMENSIONS - INCHES
INSTALLATION 8 YORK INTERNATIONAL FORM 115.20-NOM2 (105) 9 YORK INTERNATIONAL INSTALLATION FORM 115.20-NOM2 (105) Ceiling Concealed Model with Insulated Return Plenum and Filter – MODEL YPHBC . PHYSICAL DIMENSIONS - INCHES MODEL A B C D E FILTER SIZE 3YPHBC 24 22 20-1/8 30-1/8 27-1/4 10 X 24 X 1 4YP...
Page 10 - CEILING EXPOSED CABINET – MODEL YCHBC
INSTALLATION 10 YORK INTERNATIONAL FORM 115.20-NOM2 (105) 11 YORK INTERNATIONAL INSTALLATION FORM 115.20-NOM2 (105) CEILING EXPOSED CABINET – MODEL YCHBC ���� ���������� ����� ����� ����� ���� ���� ����� ���� ��������������� ����� ���� ����� ���� �������� ��� ����� ������ ����� ���� �������� �������...
Page 11 - RECESSED CEILING – MODEL YRHBC
INSTALLATION 10 YORK INTERNATIONAL FORM 115.20-NOM2 (105) 11 YORK INTERNATIONAL INSTALLATION FORM 115.20-NOM2 (105) All 1-1/2" dia. K.O.;s* 4-Pipe system only NOTES:1. Telescoping panel allows the cabinet to be installed to within 2 inches of the ceiling line. 2. Telescoping access panel shipped...
Page 12 - Unit Style; Ceiling Concealed Model with Electric Heat – MODEL YHH
INSTALLATION 12 YORK INTERNATIONAL FORM 115.20-NOM2 (105) 13 YORK INTERNATIONAL INSTALLATION FORM 115.20-NOM2 (105) 6 Y HHS - 6.0 - 240 - 3 - RH NOM. CFM (100's) 3,4,6,8,10 or 12 Unit Style Y - basic unit YP - with insulated return plenum Motor Type HH - PSC Motor HHS - SP Motor Coil Connections (lo...
Page 13 - Ceiling Concealed Model with Electric Heat,; ) All plenums include throw away filter.
INSTALLATION 12 YORK INTERNATIONAL FORM 115.20-NOM2 (105) 13 YORK INTERNATIONAL INSTALLATION FORM 115.20-NOM2 (105) Ceiling Concealed Model with Electric Heat, Insulated Return Plenum and Filter – MODEL YPHH � � ������� ������ ������ ������ �������� ��� � � ������ ��������� ����� ���� ��� ������� ��...
Page 14 - 2 YP HYB - 126 - 3 RH; Unit Voltage; MODEL YHYB – High Capacity Ceiling Concealed Model
INSTALLATION 14 YORK INTERNATIONAL FORM 115.20-NOM2 (105) 15 YORK INTERNATIONAL FORM 115.20-NOM2 (105) FEATURES: 1. Manual air vents 2. 4-speed direct drive motors 3. 1/2" copper tubing 4. Primary and secondary condensate drains on one end 5. 120/1/60Hz. motors (2) 6. 3-row and 6-row models avai...
Page 15 - FAN COILS START - UP CHECKLIST; INSTALL CHECKLIST
INSTALLATION 14 YORK INTERNATIONAL FORM 115.20-NOM2 (105) 15 YORK INTERNATIONAL FORM 115.20-NOM2 (105) FAN COILS START - UP CHECKLIST Fan INSPECTION - The fan should be inspected and cleaned, in conjunction with maintenance of the motor and bearings. It is important to keep the wheel clean in order ...
Page 16 - MAINTENANCE; MOTOR; CLEAN UNIT INTERIOR
MAINTENANCE MOTOR The blower motor should be cleaned annually and if it has oiling ports, it should be oiled with a good grade of SAE 20 oil. Normally a few drops of oil in each bearing is sufficient. COIL The coil must be kept clean by any of the following methods. 1. Cleaning with low-pressure com...