Page 2 - Johnson Controls Unitary Products; Physical and Electrical Data
413432-YTG-A-0608 2 Johnson Controls Unitary Products All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. Physical and Electrical Data MODEL TCGF24S41S1 TCGF30S41S1 TCGF36S41S1 TCGF42S41S1 TCGF48S41S1 TCGF60S41S1 Unit Supply Vo...
Page 3 - Outdoor Unit; For notes see Page 4.
413432-YTG-A-0608 Johnson Controls Unitary Products 3 Additional R-410A Charge / Orifice Size for Various Matched Systems Outdoor Unit TCGF24S41S1 TCGF30S41S1 TCGF36S41S1 TCGF42S41S1 TCGF48S41S1 TCGF60S41S1 Required Orifice or TXV 1 1TVM902 1TVM903 1TVM903 1TVM903 1TVM905 1TVM906 Factory Charge, lbs...
Page 4 - connecting line tubing.
413432-YTG-A-0608 4 Johnson Controls Unitary Products PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of inter- connecting line tubing. 2. Verify the TXV or orifice and additional charge required for specific...
Page 5 - COOLING CAPACITY - With Air Handler Coils; COIL
413432-YTG-A-0608 Johnson Controls Unitary Products 5 COOLING CAPACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL W RATED CFM NET MBH SEER EER TOTAL SENS. 14.5 SEER AC WITH MA TCGF24S41S1 MA08B 17 FC/MC24B 800 24.8 17.3 14.35 12.15 MA08B 17 FC/MC30B 800 24.8 17.3 14.3...
Page 7 - COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils
413432-YTG-A-0608 Johnson Controls Unitary Products 7 COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (Min.-max.) W RATED CFM NET MBH SEER 1 EER TOTAL SENS. TCGF24S41S1 600 - 1000 14,17 FC/MC/PC24 800 24.8 17.3 14.00 12.00 600...
Page 8 - COOLING CAPACITY - With Variable Speed Furnaces; For Notes See Page 9.
413432-YTG-A-0608 8 Johnson Controls Unitary Products COOLING CAPACITY - With Variable Speed Furnaces UNIT MODEL VARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RATED CFM Net MBH SEER EER TOTAL SENS. 14.5 SEER AC WITH VARIABLE SPEED FURNACES 2 TCGF24S41S1 PV8*A12 FC/MC/PC24A 14 750 24.8 17.5 15....
Page 12 - ACCESSORIES; Refer to Price Manual for specific model numbers.; HARD START KIT; to prevent rapid recycling of the compressor.; ROOM THERMOSTATS; - A wide selection of compatible; TYPICAL INSTALLATION; Model
413432-YTG-A-0608 12 Johnson Controls Unitary Products ACCESSORIES Refer to Price Manual for specific model numbers. HARD START KIT - Required when using TXV indoor coil. Also, provides increased starting torque for areas with lowvoltage. OFF CYCLE TIMER DELAY - Provides a 5-minute off cycle to prev...
Page 13 - COOLING PERFORMANCE DATA; AIR CONDITIONER MODEL NO.
413432-YTG-A-0608 Johnson Controls Unitary Products 13 Multipliers for determining the performance with other indoor sections. For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed tem- perature and ...
Page 14 - Air Handler
413432-YTG-A-0608 14 Johnson Controls Unitary Products Air Handler Coil T.C. S.C. KW - FC/MC/PC24 1.02 1.04 1.02 - FC/MC/PC30 1.02 1.04 1.02 - FC/MC/PC35 1.02 1.06 1.02 - FC/MC/PC36 1.02 1.06 1.02 - FC/MC/PC37 1.04 1.08 1.02 - FC/MC/PC43 1.03 1.08 1.02 - FC/MC/PC48 1.05 1.10 1.02 - HC24 0.99 1.00 1....
Page 22 - Copyright; NOTES
Subject to change without notice. Printed in U.S.A. 413432-YTG-A-0608 Copyright © 2008 by Johnson Controls, Inc. All rights reserved. Supersedes: Nothing Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069 NOTES