Page 2 - CONTENTS; Quality POLICY
CONTENTS Safety Precautions ..................................................... 3 Part Names ................................................................. 4 Manual Operation ....................................................... 5 How the air conditioner works ...................................
Page 3 - EXTENDED PARTS; SAFETY PRECAUTIONS; INSTALLATION
3 ENGLISH EN EXTENDED PARTS 1. Refrigarant Pipe 2. Pipe insulation material (Polyethylene foam 9 mm thick) 3. Vinyl tape 4. Putty REQUIRED TOOLS 1. Screw driver 9. Manifold gauge 2. Hexagonal wrench 10. Gas leak detector 3. Torque wrench 11. Vacuum pump 4. Spanner 12. Pipe clamp 5. Reamer 13. Pipe c...
Page 4 - PART NAMES; INDOOR UNIT; AUTO indicator; OPERATING TEMPERATURE; DISPLAY PANEL; Bio Filter
4 ENGLISH ( C) TEM P AUT O COO L DRY HEA T FAN HIG H MED LOW MO DE FAN SPE ED TIM ER ON SLE EP ON/O FF TIM ER OFF AIR DIR ECT ION RES ET LO CK SET TEM PER ATU RE S WIN G LE D D ISP LAY TU RBO 9 5 4 7 2 1 3 8 6 12 13 10 11 PART NAMES CAUTIONS 1. If air conditioner is used outside of the above conditi...
Page 5 - MANUAL OPERATION; AUTOMATIC OPERATION; Press Sleep button
5 ENGLISH EN MANUAL OPERATION 1 Open and lift the front panel up to an angle at which it remainsfixed with a clicking sound. 2 Press the button until the AUTO indicator is lit, the unit will work inforced AUTO mode. 3 Close the panel firmly to its original position. • Once you push the manual button...
Page 6 - OPTIMAL OPERATION; PREPARATION BEFORE INSTALLATION; SELECTION OF THE LOCATION
6 ENGLISH OPTIMAL OPERATION To achieve optimal performance, Please note the following:• Adjust the air flow direction correctly so that it is not directed on people.• Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive temperature levels.• Close doors and...
Page 7 - OUTDOOR UNIT PICTURES
7 ENGLISH EN OUTDOOR UNIT PICTURES 540 525 225 75 404 88 700 458 5 35 250 88 33 60 261 60 82 80 540 527 245 5 420 128 780 48 10 45 548 115 90 266 272 298 285 290 530 110 62 590 750 MLDA-MLJA 07-09, MLDB-MLJB 07-09, MADC-MAJC 07 MLDA-MLJA 12-18, MLDB-MLJB 12, MADC-MAJC 09-12 MLDA-MLJA 24, MLDB-MLJB 2...
Page 8 - PARTS INSTALLATION; INSTALLATION PROCEDURE; Fixing
8 ENGLISH ø 65 mm Number Name of part Q’ty 1 Installation plate 1 2 Clip anchor 8 3 Self-tapping screw A ST3.9X25 8 Connecting pipe assembly PARTS INSTALLATION NOTES INDOOR UNIT INSTALLATION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 9 - Wiring; Verification of condensate water drainage:
9 ENGLISH EN • Be careful when handling the sharp edge of the mounting plate. ■ Wiring • This indoor unit is ready for connection to the outdoor unit. • Never modify the unit by removing any of the safety guards or by passing any of the safety interlock swithces. • Connect the interconnecting cable ...
Page 10 - Indoor Unit Fixing; OUTDOOR UNIT; Fixing and Piping; Unit size
10 ENGLISH ■ Indoor Unit Fixing • Thread the indoor unit piping and cable through the hole.• Hang the top of the unit onto the upper ridge of them in mounting plate.• Make sure that the unit is correctly hung in place by sliding it to the left, then to the right.• Press the bottom left and bottom ri...
Page 11 - COLD AREA RECOMMENDATION; OK
11 ENGLISH EN To this effect, when the piping has been evacuated, close the pressure gauge tap, note the value on the gauge, thenwait for 15 minutes. If the needle moves, there is a leak in the system. Make the necessary adjustments or repairs andrepeat this procedure until the needle no longer move...
Page 12 - Note; Electrical Connections
12 ENGLISH ■ Wiring Prepare the power source for exclusive with the air conditioner.The supply voltage must comply with the rated voltage of the air conditioner: The plug socket shall be accessible after installation. Remark: All the wiring must be based on the wiring nameplate which is shown on the...
Page 13 - Wiring Connection
13 ENGLISH EN ■ Wiring Connection Models : 07-18 Indoor Outdoor Cooling only type Cooling & heating type Cooling only type Cooling & heating type Models : 24 Indoor Outdoor 1 2(N) 3 4 1 2(N) 3 4 1 2(N) 1 2(N) 3 4 Te S 1 2 (N) Cooling & heating type Cord clamp 1 2(N) 3 4 5 6 7 8 Terminal ...
Page 14 - Electrical Work
14 ENGLISH ■ Electrical Work ■ Defrosting operation (Available for heating only) 1. Condition to start defrosting: Units will switch to defrosting mode when either of the following conditions is met. a. U n i t h a s b e e n r u n n i n g u n d e r T 3 < 0 º C f o r 4 0 minutes and T3<-3ºC for...
Page 15 - MAINTENANCE; Cleaning the air filter; Maintenance; Cleaning the indoor unit and remote controller
15 ENGLISH EN MAINTENANCE ■ Cleaning the air filter A clogged air filter reduces the cooling efficiency of this unit. Please clean the filter once every 2 weeks. 1. Lift the indoor unit panel up to an angle until it stops with a clicking sound.2. Take hold of the handle of the air filter and lift it...
Page 16 - OPERATION TIPS; A white mist coming out from the indoor unit.
16 ENGLISH OPERATION TIPS The following events may occur during normal operation. 1. Protection of the air conditioner. Compressor protection• The compressor can’t restart for 3 minutes after it stops.Anti-cold air (Cooling and heating models only) • The unit is designed not to blow cold air on HEAT...
Page 17 - TROUBLE SHOOTING GUIDE; Problem
17 ENGLISH EN TROUBLE SHOOTING GUIDE Problem Probable cause Remedy A. The air conditioner does not run. 1. Power failure. 1. Wait for power resume. 2. Fuse blown or circuit breaker 2. Replace the fuse or reset the open. breaker. 3. Voltage is too low. 3. Find the cause and fix it. 4. Faulty contacto...
Page 18 - TECHNICAL SPECIFICATION; Technical Specifications : Master Gold “R22” - 50 Hz
18 ENGLISH TECHNICAL SPECIFICATION Technical Specifications : Master Gold “R22” - 50 Hz Indoor Models Unit Outdoor Unit Power Supply V/Ph/Hz Ph Power Consumption KW Running Current A Refrigerant Type Refrigerant Charge Noise level Indoor dB(A) Outdoor Power Supply V/Ph/Hz Ph Air flow m 3 /h Input Po...
Page 19 - Technical Specifications : Master Gold “R22” - 60 Hz
19 ENGLISH EN 1 1 1 1 1 TECHNICAL SPECIFICATION Technical Specifications : Master Gold “R22” - 60 Hz Indoor Models Unit Outdoor Unit Power Supply V/Ph/Hz Ph Power Consumption KW Running Current A Refrigerant Type Refrigerant Charge Noise level Indoor dB(A) Outdoor Power Supply V/Ph/Hz Ph Air flow m ...
Page 20 - Technical Specifications : Master Gold “R407C” - 50 Hz
20 ENGLISH TECHNICAL SPECIFICATION Technical Specifications : Master Gold “R407C” - 50 Hz Indoor Models Unit Outdoor Unit Power Supply V/Ph/Hz Ph Power Consumption KW Running Current A Refrigerant Type Refrigerant Charge Noise level Indoor dB(A) Outdoor Power Supply V/Ph/Hz Ph Air flow m 3 /h Input ...
Page 21 - Technical Specifications : Master Gold “R410A” - 50 Hz
21 ENGLISH EN TECHNICAL SPECIFICATION Technical Specifications : Master Gold “R410A” - 50 Hz Indoor Models Unit Outdoor Unit Power Supply V/Ph/Hz Ph Power Consumption KW Running Current A Refrigerant Type Refrigerant Charge Noise level Indoor dB(A) Outdoor Power Supply V/Ph/Hz Ph Air flow m 3 /h Inp...
Page 22 - DECLARACIÓN DE CONFORMIDAD; YORK; DECLARATION OF CONFORMITY; INSTALLATION, REMOVAL AND DISPOSAL
DECLARACIÓN DE CONFORMIDAD CM ChoiShipping Manager The product complies with the harmonized European safety standards and harmonized EMC standards listed above. We have internal production control system that ensures compliance between the manufacturer products and the technical documentation. The p...