036-21023-005 Rev. A (0802) 2 Unitary Products Group PHYSICAL AND ELECTRICAL DATA MODEL H4TS024 H4TS030 H4TS036 H4TS048 H4TS060 UNIT SUPPLY VOLTAGE 208/230-1-60 NORMAL VOLTAGE RANGE 1 187 to 252 MIN. CIRCUIT AMPACITY 13.4 15.3 18.6 32.8 35.3 MAX. OVERCURRENT DEVICE AMPS 2 20 25 30 50 60 COMPRESSOR T...
036-21023-005 Rev. A (0802) Unitary Products Group 3 * Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one.** Refer to Quick Selection Chart for specific furnace match-up. ACCESSORIES* Enhanced Coil Guard - An enhanced coil guard which offers superior protection from hail...
036-21023-005 Rev. A (0802) 4 Unitary Products Group COOLING CAPACITY - Variable Speed Furnace UNIT MODEL VARIABLE SPEED FURNACE MODEL W COIL MODEL COOLING STAGE (# CYL) RATED CFM NET MBH SEER EER TOTAL SENS. H4TS024 P1XUB12V055 17 G1UA036S17 1 600 12.6 10.2 15.0 13.7 2 820 24.4 17.2 11.7 G1FA036S17...