Page 2 - Unitary Products Group; Physical and Electrical Data; MODEL
246819-BTG-H-0208 2 Unitary Products Group All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. Physical and Electrical Data - 1 Phase MODEL EABD-F018S EABD-F024S EABD-F030S EABD-F036S EABD-F042S EABD-F048S EABD-F060S Unit Suppl...
Page 3 - Outdoor Unit; Indoor Coil; For Notes See Page 4.
246819-BTG-H-0208 Unitary Products Group 3 Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase Outdoor Unit EABD-F018S EABD-F024S EABD-F030S EABD-F036S EABD-F042S EABD-F048S EABD-F060S Required TXV 1TVM2A1 1TVM2A1 1TVM2A1 1TVM2A1 1TVM2C1 1TVM2C1 1TVM2C1 Factory Charge, lbs-oz...
Page 4 - * This loose coil match does not achieve 13 SEER.
246819-BTG-H-0208 4 Unitary Products Group * This loose coil match does not achieve 13 SEER. PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of inter- connecting line tubing. 2. Verify the orifice size and th...
Page 5 - Physical and Electrical Data - 3 Phase; DIMENSIONS; Unit
246819-BTG-H-0208 Unitary Products Group 5 All dimensions are in inches. They are subject to change with-out notice. Certified dimensions will be provided upon request. Physical and Electrical Data - 3 Phase MODEL EABD- T030S EABD- T036S EABD- T042S EABD- T048S EABD- T060S EABD- W030S EABD- W036S EA...
Page 7 - COOLING CAPACITY - With Air Handler Coils; For Notes See Page 8
246819-BTG-H-0208 Unitary Products Group 7 COOLING CAPACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL W RATED CFM NET MBH SEER EER TOTAL SENS. 1 & 3 PH 13 SEER HP WITH MA EABD-F018S MA08B 17 FC/MC18B 600 18.0 12.4 13.00 11.00 EABD-F024S MA08B 17 FC/MC24B 800 23.2...
Page 10 - COOLING CAPACITY - With Variable Speed Furnaces; For Notes See Page 11
246819-BTG-H-0208 10 Unitary Products Group COOLING CAPACITY - With Variable Speed Furnaces UNIT MODEL VARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RATED CFM NET MBH SEER EER TOTAL SENS. 1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES 2 EABD-F018S (F,L)L8VA12 FC/MC/PC18A 14 600 18.0 12.5 14.00 1...
Page 12 - HEATING PERFORMANCE - With Air Handler
246819-BTG-H-0208 12 Unitary Products Group HEATING PERFORMANCE - With Air Handler UNIT MODEL* AIR HANDLER COIL 1 MODEL ARI HEATING 2 47 ° F 17 ° F HSPF MBH COP KW MBH COP KW STD 1 & 3 PH 13 SEER HP WITH MA EABD-F018S MA08B FC/MC18B 18.0 3.62 1.46 10.5 2.28 1.35 8.00 EABD-F024S MA08B FC/MC24B 23...
Page 14 - HEATING PERFORMANCE - Upflow Furnace Coils; UNIT; no supplemental electric heat operation.
246819-BTG-H-0208 14 Unitary Products Group CP equals MBH output divided by (total KW input x 3.412).HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.— = Not Applica...
Page 15 - HEATING CAPACITY - With Variable Speed Furnaces; For Notes See Page 16.
246819-BTG-H-0208 Unitary Products Group 15 HEATING CAPACITY - With Variable Speed Furnaces UNIT MODEL VARIABLE SPEED FURNACE COIL 1 MODEL ARI HEATING 2 47 ° F 17 ° F HSPF MBH COP KW MBH COP KW STD EABD-F018S (F,L)L8VA12 FC/MC/PC18A 17.5 3.88 1.32 10.0 2.42 1.21 8.60 FL9VA12 FC/MC/PC18A 17.6 3.82 1....
Page 17 - ACCESSORIES; Blower Time Delay; SOUND POWER RATINGS; UNIT MODEL; Cooling; NOTE: ALL OUTDOOR WIRING
246819-BTG-H-0208 Unitary Products Group 17 ACCESSORIES Refer to Price Manual for specific model numbers. Start Assist Kit (2SA067*) Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower forapproximately one minute after cooling thermost...
Page 18 - COOLING PERFORMANCE DATA; CONDENSER; ID CFM
246819-BTG-H-0208 18 Unitary Products Group Multipliers for determining the performance with other indoor sections. NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreas...
Page 25 - HEATING PERFORMANCE DATA; ENTERING
246819-BTG-H-0208 Unitary Products Group 25 Multipliers for determining the performance with other indoor sections. HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO EABD-F018S EVAPORATOR COIL MODEL NO FC/MC/PC/UC18 AIR TEMP. ENTERING OUTDOOR UNIT AIR TEMP. ENTERING INDOOR COIL ID CFM 450 600 750 MB...
Page 32 - Copyright; NOTES
Subject to change without notice. Printed in U.S.A. 246819-BTG-H-0208 Copyright © by Unitary Products Group. 2008. All rights reserved. Supersedes: 246819-BTG-G-0607 Unitary 5005 Norman Product York OK Group Drive 73069 NOTES