York F3EH090 - Manual
York F3EH090 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – TABLE OF CONTENTS; INSTALLATION
- Page 3 – WARNING: Be careful when attaching the hanger rods. Use a; RIGGING AND HANDLING; These units can be rigged with slings under the bottom skid.; CLEARANCES; TABLE 1 - PHYSICAL DATA
- Page 4 – TABLE 2 - APPLICATION DATA
- Page 5 – VERTICAL / HORIZONTAL INSTALLATION; FIG. 2 - VERTICAL AND HORIZONTAL APPLICATIONS
- Page 6 – REFRIGERANT MAINS; INSTALLING REFRIGERANT MAINS; WARNING: Provisions for recovering refrigerant releases; DRAIN CONNECTION
- Page 7 – SUPPLY AIR BLOWER ADJUSTMENT; TABLE 3 - SUPPLY AIR BLOWER MOTOR; PULLEY ADJUSTMENT
- Page 8 – DROP READINGS; INDOOR COIL VS. SUPPLY AIR CFM; TABLE 4 - SUPPLY AIR BLOWER PERFORMANCE; TABLE 5 - SUPPLY AIR BLOWER PERFORMANCE
- Page 9 – (To be included with Duct System Static Resistance); TABLE 7 - BLOWER MOTOR AND DRIVE DATA; TABLE 8 - ELECTRICAL DATA
- Page 10 – POWER AND CONTROL WIRING; NOTE: Motors are wired for a 460V power supply. Refer to the
- Page 11 – ACCESSORIES
- Page 12 – MAINTENANCE
GENERAL
These completely assembled indoor units include a well-
insulated cabinet, a copper tube/aluminum fin coil, throw-
away filters, a centrifugal blower, a blower motor, an adjust-
able V-belt drive, a blower motor contactor and a small
holding charge of an inert gas. They also include a filter-
drier, an expansion valve and a distributor that are only used
during the cooling cycle plus a check valve to provide the
proper flow of refrigerant through the coil during both the
cooling and heating cycles.
Supplemental resistance heaters, a supply air plenum, a return
air grille and a base are available as accessories for field instal-
lation.
The units are shipped in the vertical position ready for field in-
stallation. For horizontal installation, reverse the solid bottom
panel and the return air duct flange on the front of the unit.
REFERENCE
This instruction covers the installation of the indoor unit. For in-
formation on the installation and operation of the matching out-
door unit, refer to Form 035-15410-002.
Renewal Parts:
•
Refer to Parts Manual for complete listing of replacement
parts on this equipment.
All forms referenced in this instruction may be ordered from:
Standard Register
Toll Free Tel.: 877-318-9675
Toll Free Fax: 877-379-7920
Installer should pay particular attention to the words: NOTE,
CAUTION and WARNING. Notes are intended to clarify or
make the installation easier. Cautions are given to prevent
equipment damage. Warnings are given to alert the installer
that personal injury and/or equipment damage may result if the
installation procedure is not handled properly.
INSPECTION
As soon as a unit is received, it should be inspected for possi-
ble damage during transit. If damage is evident, the extent of
the damage should be noted on the carrier's freight bill. A sepa-
MODELS F3EH090 & F4EH120
(50 and 60 Hz)
INSTALLATION
MANUAL
Supersedes: 515.41-N2Y (692)/035-09651-000
035-09651-001-A-0304
SPLIT-SYSTEM HEAT PUMPS
INDOOR UNITS
CAUTION
THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE
WITH THE ENCLOSED INSTALLATION INSTRUCTIONS AND
ANY APPLICABLE LOCAL, STATE, AND NATIONAL CODES
INCLUDING, BUT NOT LIMITED TO, BUILDING, ELECTRICAL,
AND MECHANICAL CODES.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION,
S E R V I C E O R M A I N T E N A N C E C A N C A U S E I N J U R Y O R
P R O P E RT Y D A M A G E . R E F E R TO T H I S M A N U A L .
F O R
ASSISTANCE OR ADDITIONAL INFORMATION, CONSULT A
QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS
SUPPLIER.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
035-09651-001-A-0304 2 Unitary Products Group TABLE OF CONTENTS GENERAL ............................................................................. 1 REFERENCE ............................................................................. 1 INSPECTION ..................................................
rate request for inspection by the carrier's agent should bemade in writing. LIMITATIONS These units must be installed in accordance with all nationaland local safety codes. If no local codes apply, installation mustconform with the appropriate national codes. Units are de-signed to meet National Sa...
035-09651-001-A-0304 4 Unitary Products Group FIG. 1 - UNIT SUSPENSION MOUNTING (Horizontal Application) Model Power Supply Voltage Variation 1 Supply Air CFM Entering Air Temperatures, ° F Cooling - wb Heating - db Min. Max. Min. Max. Min. Max. Min. Max. F3EH090 208/230-3-60 187 252 2400 3600 57 72...