Page 2 - Johnson Controls Unitary Products; TABLE OF CONTENTS; DESCRIPTION; LIST OF FIGURES; ROOF CURB DIMENSIONS (8” ROOF CURB ALSO; LIST OF TABLES; 0 SIDE AND BOTTOM SUPPLY AIR BLOWER
360101-XTG-A-0108 2 Johnson Controls Unitary Products TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 STANDARD FEATURES / BENEFITS . . . . . . . . . . . . . . . . . 1 FIELD-INSTALLED ACCESSORIES . . . . . . . . . . . . . . . . . . 3 TYPICAL APPLI...
Page 3 - FIELD-INSTALLED ACCESSORIES
360101-XTG-A-0108 Johnson Controls Unitary Products 3 STANDARD FEATURES/BENEFITS (CONT.) UTILITY CONNECTIONS MADE EASY - Electrical utility knockouts are provided through the bottom as well as the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A f...
Page 5 - TABLE 1: PHYSICAL DATA
360101-XTG-A-0108 Johnson Controls Unitary Products 5 SEER = Seasonal Energy Efficiency Ratio - the total cooling output in BTU's during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. TABLE 1: PHYSICAL DATA MODELS DEB 018 024 ...
Page 13 - FIGURE 2 - TYPICAL FIELD WIRING DIAGRAM
360101-XTG-A-0108 Johnson Controls Unitary Products 13 Note: 1. Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table. 2. The pressure thru the economizer is greater for 100% outdoor air then for 100% return air. If the resistance...
Page 15 - FIGURE 3 - UNIT DIMENSIONS; FRONT
360101-XTG-A-0108 Johnson Controls Unitary Products 15 FIGURE 3 - UNIT DIMENSIONS HIGH VO L TAGE CONN. “ x " DIA. KNOCKOUT 6 DRAIN “ NPTI CONDENS A TE LOW VO L TAGE CONN. “ DIA. KNOCKOUT FRONT CONDENSER COIL 15 4 BACK SIDE RETURN AIR OPENING SIDE SUPP L Y AIR OPENING BOT T OM RETURN AIR OPENING ...
Page 17 - TYPICAL APPLICATIONS; FIGURE 5 - TYPICAL SLAB ON GROUND INSTALLATION
360101-XTG-A-0108 Johnson Controls Unitary Products 17 TYPICAL APPLICATIONS FIGURE 5 - TYPICAL SLAB ON GROUND INSTALLATION FIGURE 6 - TYPICAL ROOF CURB INSTALLATION TO POWER SUPPLY SUPPLY AIR DUCT RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH LOCATED TO REAR OF UNIT CONTROL WIRING TO INDOOR THERM...
Page 18 - FIGURE 7 - ROOF CURB DIMENSIONS (8” Roof curb also available)
360101-XTG-A-0108 18 Johnson Controls Unitary Products FIGURE 7 - ROOF CURB DIMENSIONS (8” Roof curb also available) FIGURE 8 - ROOF CURB APPLICATION FRONT 1 1 WOOD NAILER 4 INSULATED PANELS 22 14 OPENING FOR RETURN AIR DUCT OPENING FOR SUPPLY AIR DUCT RECOMMENDED DUCT SIZE SUPPLY AIR DUCT " x &...
Page 19 - OPTIONAL CCH
360101-XTG-A-0108 Johnson Controls Unitary Products 19 FIGURE 9 - TYPICAL WIRING DIAGRAM (208/230-1-60 POWER SUPPLY) DEB MODELS 15695BASH0301 SEE DETAIL "A" T2 M1 - 2 DETAIL "A" BLK BLK CCH L1 T1 OPTIONAL CCH S / P CONFIGURATION BLK BLK CCH L1 D / P CONFIGURATION L 2 L 2
Page 20 - MECHANICAL SPECIFICATIONS; GENERAL DESCRIPTION; UNIT CABINET
360101-XTG-A-0108 20 Johnson Controls Unitary Products MECHANICAL SPECIFICATIONS GENERAL DESCRIPTION Units shall be factory-assembled, single packaged, Electric Cooling units, designed for outdoor mounted installation. They shall have built in, equal size, field convertible duct connections for down...
Page 21 - ELECTRIC HEATING SECTION
360101-XTG-A-0108 Johnson Controls Unitary Products 21 4. Unit Controls: a. Unit shall contain a large, low voltage Terminal Board for easy connection of field low voltage wiring. b. Controls shall be mounted in a large control box with tilt- out, hinged access door, allowing easy access for trouble...