Page 2 - General Information; BOTH; pumps ON; Available Controls; Operating Instructions and Parts Manual; Installation

General Information Sewage Pump Systems: Simplex System A simplex system consists of one pump, its control switch, and one basin. It is used in applications where less than six toilets (units) are discharged into a basin. The simplex unit is generally operated with a contactor to turn the pump ON an...

Page 3 - INSTALLATION BASICS:; Operation

3 www.waynepumps.com Installation (Continued) INSTALLATION BASICS: 1. NEVER lift this product by the electrical cords. 2. Install pump in a sewage pit that fulfills the minimum size requirements (24 in. minimum). Construct sump pit of tile, concrete, steel or plastic. Do not install a pit smaller th...

Page 5 - IMPORTANT; Troubleshooting Chart

5 www.waynepumps.com Symptom Possible Cause(s) Corrective Action Pump will not start or run 1. Blown fuse, tripped breaker 2. Low line voltage 3. Defective motor 4. Defective float switch 5. Stuck/ jammed impeller 6. Float obstructed 1. If blown, replace with proper sized fuse or reset breaker 2. If...