Wayne PLS Series - Manual
Wayne PLS Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Operation; Maintenance; Portable Lawn Sprinkler and Utility Pump
- Page 3 – Troubleshooting Chart; PLS Series
- Page 4 – Description; Limited Warranty
- Page 5 – Manuel d’Utilisation et Pièces de Rechange; Installation
- Page 6 – Fonctionnement
- Page 7 – Série de PLS; Guide De Dépannage
- Page 8 – Garantie Limitée
- Page 9 – XXXXX, XXXXX and XXXXX; Descripción; Serie PLS; Instalación
- Page 10 – Funcionamiento; Mantenimiento
- Page 11 – Diagnóstico de Averías
- Page 12 – Garantía Limitada
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or prop-
erty damage! Retain instructions for future reference.
© 2006 Wayne Water Systems
Description
This pump is designed to sprinkle lawns
and small gardens from lakes, ponds, or
rivers, empty or fill stock tanks, remove
standing water from flooded areas,
transfer water or boost water pressure.
Flammable liquids such as gasoline,
chemicals or corrosive liquids should
never be used with this pump.
Safety Guidelines
This manual contains information that
is very important to know and under-
stand. This information is provided for
SAFETY and to PREVENT EQUIPMENT
PROBLEMS. To help recognize this
information, observe the following
symbols.
Danger indicates
an imminently haz-
ardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
a potentially haz-
ardous situation which, if not avoided,
could result in death or serious injury.
Caution indicates a
potentially haz-
ardous situation which, if not avoided,
may result in minor or moderate injury.
Notice indicates
important infor-
mation, that if not followed, may cause
damage to equipment.
General Safety Information
1. Read these rules and
instructions carefully.
Failure to follow these
instuctions could
cause serious bodily
injury and/or property damage.
Operating Instructions and Parts Manual
PLS Series
This pump is non-
submersible. Keep
the motor dry at all times. Do not wash
the motor. Do not immerse. Protect the
motor from wet weather.
Do not allow any
part of cord or
receptacle ends to sit in water or in
damp locations.
Pump only clear water. Do
not pump flammable or
explosive fluids such as
gasoline, fuel oil,
kerosene, etc. Do not use in a flamma-
ble and/or explosive atmosphere.
Personal injury and/or property dam-
age could result.
This pump is not
designed to handle
salt water, brine, laundry discharge or
any other application which may con-
tain caustic chemicals and/or foreign
materials. Pump damage could occur if
used in these applications and will
void warranty.
All wiring must be per-
formed by a qualified
electrician. The pump
must be installed in com-
pliance with all local and national
codes.
2. Connect this product to a grounded
circuit equipped with a ground
fault circuit interruptor (GFCI)
device.
3. Before installing this product, have
the electrical circuit checked by an
electrician to ensure proper
grounding.
4. BE CERTAIN the pump
power source is dis-
connected before
installing or servicing
pump.
321602-001 1/06
5. Be sure the water source and piping
are clear of sand, dirt and scale.
Debris will clog pump and void war-
ranty.
6. Failure to protect pump and piping
from freezing could cause severe
damage and will void the warranty.
7. Do not run pump dry.
Installation
PUMPING FROM LAKES, PONDS OR
SMALL STREAMS
1. Locate pump as close as possible to
the water source, keeping the verti-
cal distance from the water to
pump as small as possible. Place
pump on level support. Protect
against flooding and excessive
moisture.
2. Long lengths of pipe or hose and
use of many fittings will reduce
pump flow. Use the smallest num-
ber of fittings and shortest possible
length of pipe or hose.
3. Be sure water is clear of debris such
as sand, mud, and gravel.
4. Connect inlet pipe or hose to pump.
The inlet connection is designed for
1" NPT thread. Rigid pipe such as
PVC will work fine for inlet and
outlet pipe. (Reminder: Minimize
length of pipe and number of fit-
tings.) An adapter for garden hose
is included (see Figure 1).
Figure 1
Pump Inlet
Pump Outlet
Portable Lawn
Sprinkler and
Utility Pump
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Use a grounded receptacle to reducethe risk of fatal electric shock. Never cut off the round grounding prong on the power cord. Cutting thecord or plug will make the pump unsafeto operate and void the warranty. 2. Turn the pump switch to the 'Off' position. 3. This pump is only for use on 120 volt (...
3 Operating Instructions and Parts Manual Symptom Possible Cause(s) Corrective Action Troubleshooting Chart Motor will not run Motor runs hot andoverload kicks off Motor runs but nowater is deliveredNote: Check primebefore looking forother causes. Unscrewpriming plug and see ifwater is in priminghol...
4 Operating Instructions and Parts Manual 1 Shaft Seal and Gasket 19041-001 1 2 Impeller 28091-001 1 3 Diffuser 28092-001 1 4 Nozzle Assembly 28093-001 1 5 Pump Housing 46036-001 1 For Replacement Parts, call 1-800-237-0987 Please provide following information: - Model number- Serial number (if any)...