Wayne EEAUP250 - Manual

Wayne EEAUP250

Wayne EEAUP250 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – Operating Instructions and Parts Manual; MAINTENANCE AND TROUBLESHOOTING; Figure 1 - Pumping Height
  • Page 3 – Figure 3 - Remove Debris From Sensor; Figure 2 - Priming Hole Location; Check Valve Sold Separately; Symptom; Sold Separately
  • Page 4 – Limited Warranty; You; MUST; send a; copy; Use this form only to maintain your records.; ATTACH YOUR RECEIPT HERE; Description; Adapter Kit
  • Page 5 – marche-arrêt automatique; MANUEL DE PIÈCES ET MODE D'EMPLOI; APPLICATION ET FONCTIONNEMENT; contactez la service au client au 1-; DIRECTIVES DE SÉCURITÉ; Tenir hors de portée des enfants!
  • Page 6 – Manuel de pièces et mode d'emploi; MAINTENANCE ET DÉPANNAGE; Figure 1 - Hauteur de pompage
  • Page 7 – Figure 2 - Emplacement du trou d'amorçage; Figure 3 - Retirer les débris du capteur; Tableau de dépannage; blessures ou à la mort.; Symptôme
  • Page 8 – Garantie limitée; Il; FAUT; envoyer; copie; pour l’autorisation et instructions concernant le renvoi.; NE PAS POSTER CE FORMULAIRE À WAYNE PUMPS.; Utiliser ce formulaire seulement pour vos dossiers.; ATTACHER LE REÇU ICI; Trousse
  • Page 9 – automático, para remoción de agua; MANUAL DE INSTRUCCIONES DE FUNCIONAMIENTO Y PIEZAS DE REPUESTO; APLICACIÓN Y FUNCIONAMIENTO; comuníquese con servicio al cliente en 1-; LEA Y SIGA TODAS LAS INSTRUCCIONES; PAUTAS DE SEGURIDAD; PROPOSICIÓN 65 DE CALIFORNIA; Mantener alejado de los niños!
  • Page 10 – Manual de instrucciones de funcionamiento y piezas de repuesto; MANTENIMIENTO Y RESOLUCIÓN DE PROBLEMAS; Figura 1 – Altura de bombeo; APLICACIÓN Y FUNCIONAMIENTO (continuación)
  • Page 11 – Figura 3 – Quite los desechos del sensor; Si la bomba funciona de forma continua, desenchufe la unidad.; Figura 2 – Ubicación del orificio de cebado; Síntoma
  • Page 12 – Garantía limitada; Usted; DEBE; enviar una; copia; Utilice este formulario sólo para su registro.; ADJUNTE AQUÍ SU RECIBO; Descripción; Juego de adaptador
Loading the manual

EEAUP250

For parts, product & service information

visit

www.waynepumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes!

Attach it to this manual or file it for safekeeping.

Auto On-Off Water Removal Portable Pump

OPERATING INSTRUCTIONS & PARTS MANUAL

Please read and save these instructions. This manual contains important Safety Warnings and Operating
Instructions. You will need to refer to it before attempting any application or maintenance. Always keep this
manual with the unit so that it will be easily accessible. Failure to read and follow these warnings and instructions
could result in property damage, serious injury or death.

Risk of electric shock. This pump

has NOT been tested for use in

swimming pool or marine areas. NEVER place pump in
pools while people are in the water. Failure to follow
COULD result in death or serious injury.

Risk of electric shock! Do NOT

handle pump with wet hands or

when standing in water or on a damp surface. Failure to
follow COULD result in death or serious injury.

Electric shock hazard! For installation

by a qualifi ed electrician only. GFCI receptacles

will provide protection against line to ground faults only. The ground
fault receptacle does NOT limit the magnitude of fault current and will
NOT prevent an electrical shock.

1. Wear safety glasses at all times when working

with pumps.

2. The unit MUST be plugged into a GFCI. For

installation by a qualified electrician only.

3. Damage to the power cord or discharge hose may occur.

Use the handle supplied on the pump.

APPLICATION AND OPERATION

Do NOT use pump if any part of the housing

switch or probe is cracked, broken, or missing.

Always disconnect

electric

supply

before attempting to install, service,
relocate, or perform any maintenance. If
the power source is out of sight, lock and
tag in open (off) position to prevent unexpected power application.
Failure to do so could result in fatal electrical shock!

Electric shock hazard. Use only

Underwriters

Laboratories

(UL)- listed extension cord with #16 gauge or larger wire
that is labeled for outdoor use. Use polarized grounding
type plugs only. Polarized plugs have one blade slightly
wider than the other and can only be inserted one way into the
outlet. Do NOT handle plug connector near water. Failure to follow
these instructions will result in serious injury or death.

This unit is NOT designed for use

as a sump pump or in sump

applications. This unit is NOT designed for use in septic
tanks or underground vaults to pump raw sewage or
effl uents. NEVER use in hazardous or explosive locations.

1. This pump has been designed with 1-1/4 in. NPT discharge

connection size. Attach pipe or fitting to the discharge or use
the supplied garden hose adapter. Thread the female end of
the garden hose to the male end of the elbow.

2. Be certain to use a hose washer (not included) on the garden

hose for correct pump operation.

DESCRIPTION

This portable, submersible utility pump is designed for automatic
use in water. The units are equipped with a 9 ft. 3-prong
grounding type power cord. The provided discharge adapter can
be used for convenient attachment to a garden hose.

UNPACKING

Inspect this unit before it is used. Occasionally, products are
damaged during shipment. If the pump or components are
damaged, contact customer service at 1-800-237-0987.

READ & FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS — DO NOT DISCARD

SAFETY GUIDELINES

This manual contains information that is important to know
and understand. This information is provided for SAFETY and
to PREVENT EQUIPMENT PROBLEMS. To help recognize this
information, observe the following symbols.

Danger indicates an imminently hazardous

situation which, if NOT avoided, WILL result

in death or serious injury.

Warning indicates a potentially hazardous

situation which, if NOT avoided, COULD

result in death or serious injury.

Caution

indicates a potentially hazardous

situation which, if NOT avoided, MAY result

in minor or moderate injury.

Notice indicates important information, that if

NOT followed, MAY cause damage to equipment.

This is the safety alert symbol. It is used to alert you to potential

bodily injury hazards. Obey all safety messages that follow this

symbol to avoid possible injury or death.

NOTE

:

Note indicates information that requires special attention.

GENERAL SAFETY INFORMATION

CALIFORNIA PROPOSITION 65

This product or its power cord may contain

chemicals, including lead, known to the

State of California to cause cancer and birth defects or other
reproductive harm. Wash hands after handling.

GENERAL SAFETY

• Read the manual(s) included with this product

carefully. Be thoroughly familiar with the controls
and the proper use of the equipment. Follow all
instructions.

• Only persons well acquainted with these rules of safe

operation should be allowed to use the unit.

Keep away from children!

Risk of fi re, explosion and/or death!

death! Pump is NOT rated for use

with fl ammable/combustible liquids, vapors or dusts. Do
NOT pump liquids that are NOT clear. Failure to follow
these instructions will result in bodily injury or death.

© 2011,
WAYNE/Scott Fetzer Company.

353901-001 4/11

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Operating Instructions and Parts Manual; MAINTENANCE AND TROUBLESHOOTING; Figure 1 - Pumping Height

2 Operating Instructions and Parts Manual www.waynepumps.com APPLICATION AND OPERATION (CONTINUED) 3. To verify pump is operating correctly. a. Disconnect pump from power source.b. Connect hose adapter and discharge hose to pump.c. Immerse pump in a bucket or tub of water at least 1-3/4 inches in de...

Page 3 - Figure 3 - Remove Debris From Sensor; Figure 2 - Priming Hole Location; Check Valve Sold Separately; Symptom; Sold Separately

3 www.waynepumps.com EEAUP250 7. If pump runs continuously, unplug the unit. Once unplugged, check for debris stuck inside the sensor body (Figure 3). Remove any trapped leaves, debris or dirt. 8. If the pump cycles on and off too often the electronic switch may need cleaning. Unplug the pump and tu...

Page 4 - Limited Warranty; You; MUST; send a; copy; Use this form only to maintain your records.; ATTACH YOUR RECEIPT HERE; Description; Adapter Kit

4 www.waynepumps.com Limited Warranty For one year from the date of purchase, WAYNE Water Systems Division ("WAYNE Pumps") will repair or re place, at its option, for the original purchaser any part or parts of its Water Pumps (“Product”) found upon examination by Wayne to be defective in ma...

Other Wayne Models