Wayne EEAUP250 - Manual

Wayne EEAUP250

This user manual covers a Wayne Auto On-Off Water Removal Portable Pump, focusing on safety protocols, operational guidelines, and troubleshooting for its portable water extraction system. The document highlights essential topics like electrical safety (e.g., avoiding wet hands or improper connections), proper installation requirements (such as stable surfaces and correct hose unwinding), maintenance procedures (including priming and debris removal), and diagnostic steps for common issues like clogs or failure to start. It also addresses regulatory warnings, including California Proposition 65 compliance, and provides limited warranty details for parts replacement.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 1 – Introduction and Safety Guidelines
  • Page 2 – Pump Setup, Operation, and Maintenance
  • Page 3 – Maintenance and Troubleshooting Diagrams
  • Page 4 – Parts Information and Warranty Details
  • Page 5 – Safety Warnings and Usage Restrictions
  • Page 6 – Application, Operation, and Water Level Settings
  • Page 7 – Inlet Maintenance and Troubleshooting Table
  • Page 8 – Parts Support and Warranty Documentation
  • Page 9 – Installation, Usage, and Regulatory Warnings
  • Page 10 – Operational Limits and Safety Procedures
  • Page 11 – Component Diagnostics and Troubleshooting
  • Page 12 – Warranty Claims and Parts Ordering
Loading the manual
Page 1

EEAUP250

For parts, product & service information

visit

www.waynepumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes!

Attach it to this manual or file it for safekeeping.

Auto On-Off Water Removal Portable Pump

OPERATING INSTRUCTIONS & PARTS MANUAL

Please read and save these instructions. This manual contains important Safety Warnings and Operating
Instructions. You will need to refer to it before attempting any application or maintenance. Always keep this
manual with the unit so that it will be easily accessible. Failure to read and follow these warnings and instructions
could result in property damage, serious injury or death.

Risk of electric shock. This pump

has NOT been tested for use in

swimming pool or marine areas. NEVER place pump in
pools while people are in the water. Failure to follow
COULD result in death or serious injury.

Risk of electric shock! Do NOT

handle pump with wet hands or

when standing in water or on a damp surface. Failure to
follow COULD result in death or serious injury.

Electric shock hazard! For installation

by a qualifi ed electrician only. GFCI receptacles

will provide protection against line to ground faults only. The ground
fault receptacle does NOT limit the magnitude of fault current and will
NOT prevent an electrical shock.

1. Wear safety glasses at all times when working

with pumps.

2. The unit MUST be plugged into a GFCI. For

installation by a qualified electrician only.

3. Damage to the power cord or discharge hose may occur.

Use the handle supplied on the pump.

APPLICATION AND OPERATION

Do NOT use pump if any part of the housing

switch or probe is cracked, broken, or missing.

Always disconnect

electric

supply

before attempting to install, service,
relocate, or perform any maintenance. If
the power source is out of sight, lock and
tag in open (off) position to prevent unexpected power application.
Failure to do so could result in fatal electrical shock!

Electric shock hazard. Use only

Underwriters

Laboratories

(UL)- listed extension cord with #16 gauge or larger wire
that is labeled for outdoor use. Use polarized grounding
type plugs only. Polarized plugs have one blade slightly
wider than the other and can only be inserted one way into the
outlet. Do NOT handle plug connector near water. Failure to follow
these instructions will result in serious injury or death.

This unit is NOT designed for use

as a sump pump or in sump

applications. This unit is NOT designed for use in septic
tanks or underground vaults to pump raw sewage or
effl uents. NEVER use in hazardous or explosive locations.

1. This pump has been designed with 1-1/4 in. NPT discharge

connection size. Attach pipe or fitting to the discharge or use
the supplied garden hose adapter. Thread the female end of
the garden hose to the male end of the elbow.

2. Be certain to use a hose washer (not included) on the garden

hose for correct pump operation.

DESCRIPTION

This portable, submersible utility pump is designed for automatic
use in water. The units are equipped with a 9 ft. 3-prong
grounding type power cord. The provided discharge adapter can
be used for convenient attachment to a garden hose.

UNPACKING

Inspect this unit before it is used. Occasionally, products are
damaged during shipment. If the pump or components are
damaged, contact customer service at 1-800-237-0987.

READ & FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS — DO NOT DISCARD

SAFETY GUIDELINES

This manual contains information that is important to know
and understand. This information is provided for SAFETY and
to PREVENT EQUIPMENT PROBLEMS. To help recognize this
information, observe the following symbols.

Danger indicates an imminently hazardous

situation which, if NOT avoided, WILL result

in death or serious injury.

Warning indicates a potentially hazardous

situation which, if NOT avoided, COULD

result in death or serious injury.

Caution

indicates a potentially hazardous

situation which, if NOT avoided, MAY result

in minor or moderate injury.

Notice indicates important information, that if

NOT followed, MAY cause damage to equipment.

This is the safety alert symbol. It is used to alert you to potential

bodily injury hazards. Obey all safety messages that follow this

symbol to avoid possible injury or death.

NOTE

:

Note indicates information that requires special attention.

GENERAL SAFETY INFORMATION

CALIFORNIA PROPOSITION 65

This product or its power cord may contain

chemicals, including lead, known to the

State of California to cause cancer and birth defects or other
reproductive harm. Wash hands after handling.

GENERAL SAFETY

• Read the manual(s) included with this product

carefully. Be thoroughly familiar with the controls
and the proper use of the equipment. Follow all
instructions.

• Only persons well acquainted with these rules of safe

operation should be allowed to use the unit.

Keep away from children!

Risk of fi re, explosion and/or death!

death! Pump is NOT rated for use

with fl ammable/combustible liquids, vapors or dusts. Do
NOT pump liquids that are NOT clear. Failure to follow
these instructions will result in bodily injury or death.

© 2011,
WAYNE/Scott Fetzer Company.

353901-001 4/11

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Wayne
Model
EEAUP250
Document type
Manual
Language(s)
English, Spanish, French
Pages
12
File size
1.2 MB
Format
PDF

Summary

Page 1 - Introduction and Safety Guidelines

Overview of operating instructions and parts manual, including safety warnings, hazard symbols, unpacking procedures, general safety guidelines, and basic application procedures.

Page 2 - Pump Setup, Operation, and Maintenance

Instructions for proper installation, operational parameters (water depth, pumping height), electrical safety precautions, handling guidelines, and troubleshooting steps for starting failures or hose clogs.

Page 3 - Maintenance and Troubleshooting Diagrams

Guidance for pump maintenance, locating priming holes, debris removal procedures, and a chart detailing symptoms, causes, and corrective actions for common pump issues.

Ask a question