Wayne CWS100 - Manual

Wayne CWS100

Wayne CWS100 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 2 – Figure 1
  • Page 3 – Installation; Type; Illustration A
  • Page 4 – NOTE; Figure 4 - Two Pipe Jet
  • Page 5 – Operating Instructions & Parts Manual; Figure 6 - Horizontal Tank
  • Page 6 – Figure 11 - Voltage Selector
  • Page 7 – Maintenance; LUBRICATION; Figure 13 - Convertible Well Pump
  • Page 8 – SHALE; ater Supplies; Figur
  • Page 9 – Troubleshooting Chart
  • Page 10 – Replacement Parts List; Part Number for Models
  • Page 11 – Performance
  • Page 12 – Limited Warranty; You
  • Page 13 – Description
  • Page 15 – TABLEAU 1 - MONTAGES DE POMPE À JET/RÉSERVOIR
  • Page 16 – INSTALLATION POUR PUITS PROFOND; Figure 4 - Jet à Deux Tuyaux; Instructions D’utilisation et Manual de Pièces; TABLEAU 2 - TAILLES DE TUYAUX
  • Page 17 – Figure 6 - Réservoir Horizontal; Figure 7 - Réservoir Vertical
  • Page 18 – VIDANGE DE LA POMPE; Figure 12 - Soupape de Contrôle
  • Page 19 – Entretien; RÉSERVOIR CHARGÉ D’AVANCE; Figure 13 - Pompe Transformable; Figure 16 - Arvre de Moteur
  • Page 20 – ANG; ARGILE
  • Page 21 – Tableau de dépannage; Symptôme
  • Page 22 – Liste de pièces de rechange; Numéro de piéce pour modèles:
  • Page 23 – Pression de Décharge kPa
  • Page 24 – Garantie Limitée; DEVEZ
  • Page 25 – Descripción
  • Page 26 – Figura 1
  • Page 27 – Instalación; Instale una válvula de aspiración en; Tipo
  • Page 28 – INSTALACIÓN EN UN PROFUNDO; Figura 5 - Chorro de 1 Tubo
  • Page 29 – Manual de instrucciones de operación y piezas; Figura 6 - Tanque horizontal
  • Page 30 – DRENAJE DEL BOMBA; Figura 11 - Selector de voltaje; Figura 12 - Válvula de Control
  • Page 31 – Eléctricas; DRENAJE DEL TONQUE; Figura 13 - Bomba Convertible para Pozos; Figura 15 - Reemplazo de la Placa Sellado
  • Page 32 – Mantenimiento; Sitúe la pieza rotatoria del sello del; Figura 16 - Eje del Motor; Figura 17 - Suministros de Agua
  • Page 33 – Tabla de Identificación de Problemas; Síntoma
  • Page 34 – Lista de Partes de Reparación; Número de Parte para Modelos:
  • Page 35 – Rendimiento; Presión de Descarga bar
  • Page 36 – Garantía Limitada; enviarnos una
Loading the manual

Operating Instructions and Parts Manual

CWS50, CWS75 and CWS100

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

For parts, product & service information

visit

www.waynepumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes!

Attach it to this manual or file it for safekeeping.

340006-001 3/09

© 2009 Wayne Water Systems

Convertible Well Jet
Pump Water Systems

4. Secure the discharge line before

starting the pump. An unsecured
discharge line will whip and possibly
cause personal injury and/or
property damage.

5. Check hoses for weak or worn

condition before each use. Make
certain all connections are secure.

6. Periodically inspect pump and

system components. Perform routine
maintenance as required (See
Maintenance).

7.

Personal Safety:

a. Wear safety glasses at all times

when working with pumps.

b. Keep work area clean, uncluttered

and properly lighted replace all
unused tools and equipment.

c. Keep visitors at a safe distance

from work area.

d. Make the workshop child proof:

use padlocks, master switches and
remove starter keys.

8. Do not pump chemicals or corrosive

liquids. Pumping these liquids
shortens the life of the pumps seals
and moving parts and will void the
warranty.

9. When installing pump, cover the

well to prevent foreign matter from
falling into well and contaminating
the water and damaging internal
mechanical pumping components.

10. Always test the water from the well

for purity before use. Check with
local health department for test
procedure.

11. Complete pump and piping system

MUST be protected against below
freezing temperature. Freezing
temperatures could cause severe
damage and void the warranty.

General Safety
Information

CALIFORNIA PROPOSITION 65

This

product

contains

chemicals,

including lead, known to the State of
California to cause birth defects and
other reproductive harm. Wash hands
after handling.

GENERAL SAFETY

1. Read all manuals included with this

product carefully. Be thoroughly
familiar with the controls and the
proper use of the equipment.

2. Know the pump application,

limitations and potential hazards.

Always install a

pressure relief valve

to match the system pressure rating and
the maximum flow rate.

Do not use to

pump flammable

or explosive fluids such as gasoline,
fuel oil, kerosene, etc. Do not use in
explosive atmospheres. Pump should
only be used with liquids compatible
with pump component materials.
Failure to follow this warning can result
in personal injury and/or property
damage.

Disconnect

power

and release all

pressure from the system before
attempting to install, service, relocate
or perform any maintenance. Lock the
power disconnect in the open position.
Tag the power disconnect to prevent
unexpected application of power.

Install a screen

around the inlet pipe

to prevent entrapment of swimmers.

3. Drain all liquids from the system

before servicing.

Description

Jet pumps are single stage domestic water
pumps designed for pumping potable
water in applications where the water is up
to 100 feet (deep well pump). A pressure
switch is a standard feature. A built-in
control valve is available on deep well
pumps. Deep well pumps can be mounted
to either a pre-charged, conventional type
or free standing pressure tank.

Unpacking

After unpacking the jet pump, carefully
inspect for any damage that may have
occurred during transit. Check for loose,
missing or damaged parts.

Safety Guidelines

This manual contains information
that is very important to know
and understand. This information
is provided for SAFETY and to
PREVENT EQUIPMENT PROBLEMS. To
help recognize this information, observe
the following symbols.

Danger indicates an

imminently

hazardous situation which, if not avoided,
WILL result in death or serious injury.

Warning indicates a

potentially

hazardous situation which, if not avoided,
COULD result in death or serious injury.

Caution

indicates a

potentially

hazardous situation which, if not avoided,
MAY result in minor or moderate injury.

Notice

indicates

important

information, that if not followed, may
cause damage to equipment.

NOTE:

Information that requires special

attention.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Figure 1

2 Operating Instructions & Parts Manual CWS50, CWS75 and CWS100 www.waynepumps.com General Safety Information (Continued) TANKS - CONVENTIONAL STORAGE The function of the tank is to store a quantity of water under pressure. When full, the tank contains approximately 2/3 water and 1/3 compressed ...

Page 3 - Installation; Type; Illustration A

3 www.waynepumps.com Pre-Installation (Continued) PACKAGE SYSTEMS There are four jet pump/tank assemblies sold as packages (Chart 1). WELLS A new well should be pumped clear of sand before installing the pump. Sand will damage the pumping parts and seal. The draw-down level of the well should not ex...

Page 4 - NOTE; Figure 4 - Two Pipe Jet

4 www.waynepumps.com Installation (Continued) DRIVEN WELL • Drive the point several feet below the water table. NOTE : A packer type foot valve can be installed in the well (Figure 3, Illustration B). This type of foot valve allows the well to be filled with water when priming and makes the inlet pi...

Other Wayne Models

All Wayne Other