  • Page 2 – Operating Instructions and Parts Manual; Deep Well Submersible Pump; General Safety; Table 1 - recommended fusing data; WIrInG InSTallaTIOn; do NoT handle; electrical System; WIrInG COnneCTIOnS
  • Page 3 – use only control; Install circuit protection and; not; required. See Figure; Volts; none; Table 4 - Control box chart; Follow color coding when; disconnect box
  • Page 4 – Installation; Too much
  • Page 5 – Connect a pipe elbow, a short length; seal tape on; figure 8 - Temporary connections; STanDarD TanK HOOKUP; figure 9 - Typical Pre-charged Tank Installation
  • Page 6 – figure 10 - Typical Standard Tank Installation; Troubleshooting Chart
  • Page 7 – Deep Well Submersible ump
  • Page 8 – limited Warranty; you
  • Page 9 – Généralités Sur la; PrOPOSITIOn 65 De CalIfOrnIe; Description
  • Page 10 – Instructions D’utilisation et Manual de Pièces; Puits profond pompes submersibles; Risque de choc; Système électrique; BranCHeMenTS ÉleCTrIQUeS
  • Page 11 – boîte de contrôle; Suivre le codage de couleur lors du; figure 1a - Boîtier de sectionnement
  • Page 12 – ÉPISSUre De fIl; Ne pas arrêter de; la fréquence
  • Page 13 – InSTallaTIOn De POMPe; figure 8 - Branchements temporaires; figure 9 - Installation typique d'un réservoir chargé d'avance
  • Page 14 – figure 10 - Installation typique d'un réservoir standard; Installer le dispositif d'étanchéité; Ne PAs laisser la
  • Page 15 – notes
  • Page 16 – Mesures Correctives; Réservoir hydropneumatiques:; Tableau de dépannage
  • Page 17 – Faire marcher la pompe en dépit de la
  • Page 18 – Garantie limitée; Vous; DeVeZ; garder votre reçu d’achat avec ce bulletin. Il est; nÉCeSSaIre; d’envoyer une; copie; du reçu d’achat avec le; fIXer VOTre faCTUre ICI
  • Page 19 – Descripción; PrOPOSICIón 65 De CalIfOrnIa
  • Page 20 – Manual de instrucciones de operación y piezas; Bomba sumergible para pozos profundos; Información general de; COneXIOneS De CaBleaDO; Sistema eléctrico; CaBleaDO/COneXIón a TIerra; No manipule la
  • Page 21 – use únicamente; Instale la protección del circuito y; Voltios; nada; Tabla 4 – Cuadro de la caja de control; Siga el código de color al conectar
  • Page 22 – Instalación; eMPalMe De CaBleS; Mantenga el; la frecuencia y el; Para evitar dejar
  • Page 23 – InSTalaCIón De la BOMBa; NuNCA haga; figura 8 - Conexiones temporales; figura 9 - Instalación típica de un tanque precargado
  • Page 24 – utilice sólo; figura 10 - Instalación típica de un tanque estándar
  • Page 25 – notas
  • Page 26 – Tabla de Identificación de Problemas; no intente desarmar la bomba ni
  • Page 27 – Tanques de aire sobre agua:
  • Page 28 – Garantía limitada; enviarnos una
Loading the manual

Operating Instructions and Parts Manual

T50S10-2, T50S10-4, T51S10-4,

T75S10-2, T75S10-4, T100S10-2

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

For parts, product & service information

visit

www.waynepumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes!

Attach it to this manual or file it for safekeeping.

340601-001 5/11

© 2011 Wayne/Scott Fetzer Company.

Deep Well
Submersible Pumps

4. Do not pump chemicals or corrosive

liquids. Pumping these liquids
shortens the life of the pumps seals
and moving parts and

WIll void

warranty.

5. When installing pump, prevent

foreign matter from falling into
well, contaminating the water and
damaging internal mechanical
components.

6. always test the water from the well

for purity before use. Check with
local health department for test
procedure.

7. Do not run the pump dry or

damage will occur and

WIll void

warranty.

All wiring should

be performed by a

licensed or certified electrician.

8. For maximum safety, the unit should

be connected to a grounded circuit
equipped with a ground fault circuit
interrupter (GFCI) device.

9. Make sure the line voltage and

frequency of electrical current
supply agrees with the motor wiring.

10. Do not attempt repairs to the

electric motor. all repairs to the
motor must be completed at a
licensed or certified electrical motor
repair shop.

11. avoid kinking electrical cord

and protect electrical cord from
sharp objects, hot surfaces,
oil and chemicals. Replace or
repair damaged or worn cords
immediately.

Risk of electric

shock! NeveR

connect the green wire (or green and
yellow wire) to a live terminal!

General Safety

Information

CalIfOrnIa PrOPOSITIOn 65

This product

contains chemicals,

including lead, known to the state of
California to cause birth defects and
other reproductive harm. Wash hands
after handling.

General SafeTy

1. Read the instruction manual

included with the product carefully.
Be thoroughly familiar with the
controls and the proper use of the
equipment.

2. Know the pump application,

limitations and potential hazards.

do NoT use to

pump flammable

or explosive fluids such as gasoline,
fuel oil, kerosene, etc. do NoT use in
explosive atmospheres. Pump should
only be used with liquids compatible
with pump component materials.
Failure to follow this warning can result
in personal injury and/or property
damage.

disconnect power

and release all

pressure from the system before
attempting to install, service, relocate
or perform any maintenance. lock the
power disconnect in the open position.
Tag the power disconnect to prevent
unexpected application of power.

3.

Personal Safety:

a. Wear safety glasses at all times

when working with pumps.

b. Keep work area clean, uncluttered

and properly lit.

c. Keep visitors at a safe distance from

work area.

Description

this submersible pump is designed to
supply water at the required pressure with
high efficiency and a long service life. to
maximize pump life, care must be taken in
its installation and usage.

Unpacking

after unpacking the submersible pump,
carefully inspect for any damage that
may have occurred during transit. Check
for loose, missing or damaged parts.

Safety Guidelines

this manual contains information
that is very important to know
and understand. this information
is provided for SaFety and to
PReVent eQUIPMent PRoBLeMS. to
help recognize this information, observe
the following symbols.

danger indicates an

imminently

hazardous situation which, if NoT
avoided, WIll result in death or serious
injury.

Warning indicates a

potentially

hazardous situation which, if NoT
avoided, Could result in death or serious
injury.

Caution indicates a

potentially

hazardous situation which, if NoT
avoided, MAY result in minor or moderate
injury.

Notice indicates

important

information, that if NoT followed, MAY
cause damage to equipment.

nOTe:

Information that requires special

attention.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Operating Instructions and Parts Manual; Deep Well Submersible Pump; General Safety; Table 1 - recommended fusing data; WIrInG InSTallaTIOn; do NoT handle; electrical System; WIrInG COnneCTIOnS

2 Operating Instructions and Parts Manual Deep Well Submersible Pump www.waynepumps.com General Safety Information (Continued) nOTe: See Installation Wiring Diagrams for typical wiring hookups and control box identification. fuse Size HP Volts Standard Dual elem. 1/2 230 20 10 3/4 230 25 5 1 230 30 ...

Page 3 - use only control; Install circuit protection and; not; required. See Figure; Volts; none; Table 4 - Control box chart; Follow color coding when; disconnect box

3 www.waynepumps.com electrical System (Continued) use only control box specified for your pump. Make sure motor and control box match (see Table 4, on page 3). Failure to do so WIll void warranty. 4. Install circuit protection and component protection in compliance national electrical Code, Part 1....

Page 4 - Installation; Too much

4 www.waynepumps.com Operating Instructions and Parts Manual Deep Well Submersible Pump Installation WIre SPlICInG Splice wire to motor leads. Use only copper wire for connections to pump/motor assembly and control box. Heat shrink splice instructions (wire sizes No. 14, 12 and 10 AWG [2, 3 and 5mm ...

Other Wayne Models

All Wayne Other