Page 2 - Radiance Direct Vent /Natural Vent Gas Heater; Completion of sale, nor for purpose of resale,; Installation & Operating Instructions
3 Radiance Direct Vent /Natural Vent Gas Heater 20004188 The Radiance Direct Vent/Natural Vent Room Heater, Model Nos. 3350 thru 3354, 3360 thru 3369 and 3390 thru 3399, is a vented gas appliance listed to the ANSI standard Z21.88b-2002 and CSA-2.33b-2002 for Vented Room Heaters, and CSA 2.17-M91, G...
Page 3 - Radiance Direct Vent/Natural Vent Gas Heater; Radiance Direct Vent/Natural Vent Stove Dimensions; Attention
4 4 Radiance Direct Vent/Natural Vent Gas Heater 20004188 29 ��� " (7.6cm) 31" (7.9cm) 7" Outer Dia. (1.8cm) � ����������� � 4 ��� " (1.2cm) 14 ��� " (3.7cm) ST126 RDV40 dimensions 10/99 � � � � � � � � 28" (711mm) 5" (127mm) 9 ��� " (241mm) 18 ��� " (464mm) Suppl...
Page 4 - Installation Requirements; Locating The Stove; Possible stove locations.; Direct Vent System Only; Stardance; Clearance Requirements; Minimum Clearances to Combustible Materials
5 Radiance Direct Vent /Natural Vent Gas Heater 20004188 Installation Requirements The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEP-TION: Do not derate this appliance for altitude. Main-tai...
Page 5 - Parallel installation, minimum back and side clear-; Corner installation, minimum corner clearances and; Minimum wall centerline.; Sidewall Clearance; Direct Vent Only
6 6 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Parallel Installation: Minimum Clearance and Flue Centerline, Direct Vent and Natu- ral Vent Fig. 3 Parallel installation, minimum back and side clear- ances, and flue centerlines. ST130 ���������������������� 42" (1070mm) Min. Alcove Widt...
Page 6 - Radiance Direct Vent/Natural Vent; Input; Gas Inlet and Manifold Pressures; ment, alteration, service or maintenance; Horizontal Termination -
7 Radiance Direct Vent /Natural Vent Gas Heater 20004188 Radiance Direct Vent/Natural Vent Certified to: ANSI Z21.88b-2002 / CSA 2.33b-2002 Vented Gas Fireplace Heaters Gas Specifications Max. Min. Input Input Model Fuel Gas Control BTU/h BTU/h RDVODRN Nat Millivolt 35,000 25,000 RDVODRP Prop Millivol...
Page 7 - Vent Termination Clearances; NOTE: The restrictor; Vertical vent termination window.; IMPORTANT
8 8 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Vent Termination Clearances When planning the installation, consider the location of the vent terminal and clearances. Some of the most common clearances to keep in mind are shown in Figure 9. Important: All vent clearances must be maintained...
Page 9 - General Venting Information - Termination Location; Canadian Installations
10 10 Radiance Direct Vent/Natural Vent Gas Heater 20004188 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED H I ����� ������ ����� ������ �������� �������� ����� ������ V B CFM145a DV Termin Location 5/01/01 Rev. 12/05/01 sta INS...
Page 10 - Venting Runs; (Measured from top of the unit before any elbow); NOTE: When venting staight vertical, without any; Termination Clearances; Termination clearances.; Venting Requirements - Natural Vent Only; Vent termination window - Natural Vent ONLY.
11 Radiance Direct Vent /Natural Vent Gas Heater 20004188 ����������������������������������� Venting Runs Horizontal Run (in feet) Vertical Run (in feet) (Measured from top of the unit before any elbow) A: Vertical installations up to 36 feet (12m) in height. Up to an 18 ft. horizontal vent run can...
Page 11 - Venting Requirements and Options -; Approved Vent System Components; Simpson DuraVent Components; Direct vent pipe may be used on the Natural
12 12 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Venting Requirements and Options - Direct Vent ONLY Approved Vent System Components The Stardance Heater must be vented to the outdoors through an adjacent exterior wall or through the roof. The venting system must be comprised of the appro...
Page 12 - Slide stove back just far enough to access rear leg; Assembly Procedures; Failure to position the parts in accor-; WARNING; Tools Required; Radiance; Carefully tip stove onto back legs. Leave pallet under
13 Radiance Direct Vent /Natural Vent Gas Heater 20004188 ST720 Radiance slide stove back 7/30/02 djt ST720 Fig. 12 Slide stove back just far enough to access rear leg holes. Assembly Procedures Failure to position the parts in accor- dance with these diagrams or failure to use only parts specificall...
Page 13 - JUV; Attach the fan rheostat.; Install the Optional Fan; Remove rear shroud.; Fan kit components.; Attach blower assembly and snapstat.
14 14 Radiance Direct Vent/Natural Vent Gas Heater 20004188 ST347a JUV FK28 rheostat install 9/21/00 Rheostat Retaining Collar Rheostat Knob ST347a Fig. 17 Attach the fan rheostat. Rheostat Install the Optional Fan If you are installing the optional convection Fan Kit #2767 (FK26), continue here. It...
Page 14 - Venting System Assembly - Direct Vent; For Canadian installations:; Install the Vent Adapter Pipe; Install the restrictor plate only if required for the vent-; Attach the Inner Vent Assembly to the stove.; attach inner pipe; Connect the inner starter with the next section of; attach inner assy
15 Radiance Direct Vent /Natural Vent Gas Heater 20004188 Venting System Assembly - Direct Vent General Information The Radiance is approved for installation only with the vent components listed on Page 11. Follow the vent component instructions exactly. For U.S. installations: The venting system mu...
Page 15 - Side Wall Termination Assembly; Discard the inner starter pipe; install outer adpater; dura vent; Simpson DuraVent - install inner adpater pipe.; Vent Opening; Combustible Wall; Locate vent opening.; CFM System
16 16 Radiance Direct Vent/Natural Vent Gas Heater 20004188 2. Measure the wall thickness and cut the wall sleeve sections to proper length (MAXIMUM 12”). Assemble the sleeve with the #8 sheet metal screws supplied. Attach the firestop plate to the sleeve end with the holes. (Fig. 25) NOTE: The wall ...
Page 16 - For DuraVent pipe only:; Zero Clearance Sleeve; Assemble the wall sleeve and firestop.; measure thru wall; Measure the horizontal length.; install pipe thru wall; Install the horizontal pipe and wall plate parts.
17 Radiance Direct Vent /Natural Vent Gas Heater 20004188 For DuraVent pipe only: Install vent pipe by align- ing the locking system together, sliding the pipes together and twisting clockwise. • Install 90° elbow. Twist lock as before. • Slide the wall plate over horizontal run before at- taching t...
Page 17 - Vent Assembly; install snorkel; Snorkel kit installation.; Vent Termination Below Grade; If the; snorkel detail; Use extension brackets to mount snorkel against; install wall terminal; Install the vent terminal.
18 18 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Vertical (Through the Roof) Vent Assembly Note that all vertically terminated installations must, where specified, use the restrictor plate to comply with Vertical Termination Window (Page 7, Figure 8), included in the hardware bag. The plat...
Page 18 - vent thru roof; Roof support and flashing.; Venting System Assembly - Natural Vent; Install firestops and attic insulation shield.
19 Radiance Direct Vent /Natural Vent Gas Heater 20004188 ST221 vent thru roof 12/99 Storm Collar Sealant Upper edge of flange goes under upper shingles Flashing #7DVSKV (A, B, or F) Roof Support Use three #5 sheet metal screws at each joint ST221 Fig. 33 Roof support and flashing. Make certain the ve...
Page 19 - Install Log Set; Remove the stove front.; Release the latches to remvoe the glass frame.; Install the Vent Pipe; attach draft hood
20 20 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Install Log Set Before beginning log installation, remove stove front and glass frame. Refer to Figures 36 and 37. ST139 Radiance remove front 4/20/01 djt ST139 Fig. 36 Remove the stove front. ST141 pull glass latch 10/99 ST141 Fig. 37 Rele...
Page 20 - Install the left and right rear logs and the right log.; Install the right log by engaging hole on the bottom; Connect the Gas Supply Line; Gas connection should be made in ac-; Radiance logs; Completed log installation.; Top View; Lava rock placement.; Radiance logs
21 Radiance Direct Vent /Natural Vent Gas Heater 20004188 LG156 Radiance logs 4/23/01 djt LG156 Fig. 39 Install the left and right rear logs and the right log. Decorative Grate Right Log Right Rear Log Left Rear Log Left Bracket Right Bracket 4. Install the right log by engaging hole on the bottom w...
Page 21 - Use only a thermostat rated for 500 - 750 millivolts.; Install ON/OFF Switch; PILOT; attach switch; Attach switch wires to valve.; Install the Mesh and Grille; THIS APPLIANCE SHOULD BE CON-; In order to connect Natural Gas,; CAUTION; attach switch assy; Attach switch assembly to rear shroud.; Thermostat
22 22 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Thermostat Connection (optional) Use only a thermostat rated for 500 - 750 millivolts. Check the table below for the appropriate gauge ther-mostat wire to use for the length of lead required in your installation. 1. Install the wall thermos...
Page 22 - Operation; Your First Fire; handle holder; When not in use, store handle in the handle holder.; Pilot Assembly location.; To open the front doors, turn handle counterclockwise.; Flame & Temperature Adjustment; Flame adjustment knob for Honeywell valve.; Flame Characteristics; Correct pilot and burner flame patterns.; Pilot flame; SIT Pilot
23 Radiance Direct Vent /Natural Vent Gas Heater 20004188 The Radiance is shipped with the operable door front plate. The stove may be operated with the doors either open or closed. To open the front doors, insert the handle into the door latch stub and turn it to the right and up. (Fig. 44) When no...
Page 23 - FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting and Operating Instructions; Lighting Instructions; Lighting instructions
24 24 Radiance Direct Vent/Natural Vent Gas Heater 20004188 3. Open control access panel.4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace.3. Fo...
Page 24 - Troubleshooting / Honeywell #8420 Gas Control System; SYMPTOM
25 Radiance Direct Vent /Natural Vent Gas Heater 20004188 Troubleshooting / Honeywell #8420 Gas Control System NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position. WARNING: REMOVE THE GLASS PANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WORK...
Page 25 - comfort valve; Transmitter diagram.; Honeywell; Comfort control valve.
26 26 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Instructions for RF Comfort Control Valve The Comfort Control valve allows remote control of temperature, fan and flame appearance. NOTE: The antenna should hang in free air away from grounded metal. Operation 1. If the manual switch is in r...
Page 26 - Local Path
28 28 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Light pilot burner Set manual switch to local or remote Release pilotstat knob. Turn pilotstat knob from PILOT to ON. If manual switch is set to LOCAL, did main burner light and fan turn on? Turn pilotstat knob to PILOT to turn off main bur...
Page 27 - above; Auto Path; below
29 Radiance Direct Vent /Natural Vent Gas Heater 20004188 If the manual switch is set to REMOTE, press the mode button to display AUTO on the transmitter. Does the transmitter display the room and temperture setting? If the settings is above room temperture on the transmitter, does the main valve an...
Page 28 - If an Error Code 3 is observed while performing the; Blower; Comfort Valve wiring diagram.
27 Radiance Direct Vent /Natural Vent Gas Heater 20004188 Auto Mode In the AUTO mode, the room temperature, set tem-perature, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons.When the control is in the AUTO mode, the main burner will turn on/off or modulate bas...
Page 29 - All Models; Depress and turn center plunger.; Model; RDVOD, RDVOD with; Table 2. Air Shutter Adjustment; Remove and replace injector orifices.; injector orifice; Conversion to Natural Gas; Table 1. Injector Orifice Size Matrix
32 32 Radiance Direct Vent/Natural Vent Gas Heater 20004188 All Models 22. Replace burner. Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base. Lower the right hand side down i...
Page 30 - Maintenance; painted surfaces; Remove the Stove Front.
33 Radiance Direct Vent /Natural Vent Gas Heater 20004188 Maintenance Your Radiance Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly. Annual System Inspection Have the entire heater and venting syst...
Page 31 - Gasket Replacement; Determine the correct length of gasket by laying it; Inspect the Vent System Annually; glass gasket detail; Wrap the gasket material around the outside edge of; Correct flame pattern.; Release the latches to remove the glass frame.
34 34 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Gasket Replacement The Radiance Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced. New gasket is available from your dealer.S...
Page 32 - BLK; rdv connections diag.; Schematic Diagram; Wiring Diagrams; On/off switch and optional thermostat circuit.; Used on
35 Radiance Direct Vent /Natural Vent Gas Heater 20004188 NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP- PLIED WITH THE APPLIANCE, MUST BE RE-PLACED, IT MUST BE REPLACED WITH TYPE SF-2, 200°C WIRE OR ITS EQUIVALENT. FAN JUNCTION BOX FAN POWER CORD Strain Relief Chassis Ground BLK GRN GRN WHT ON / OFF Rh...
Page 33 - RDVOD; Manifold Assembly
36 36 Radiance Direct Vent/Natural Vent Gas Heater 20004188 46 1a 1b 1c PILOT ON OFF PILOT ADJ LO HI CEMENT 2 3 6 8 7 5 34 4 35 4188 RDVOD parts 6/11/01 djt 32 33 29a,b, c,d 9 30 LOCAL REMOTE ON • PILOT OFF • LED 23 24 25 7 10a,b 11a,b 12a 12b 12c 13 14 15 16 18 17 19 20a,b 22 21a,b 31 27 26 36 38 4...
Page 35 - Fuel Conversion Kits
38 38 Radiance Direct Vent/Natural Vent Gas Heater 20004188 Radiance Direct Vent/Natural Vent Gas Heater (RDVOD) Models: 3225 thru 3232, 3350 thru 3354, 3360 thru 3369, 3390 thru 3399 (continued) Fuel Conversion Kits Conversion Kit, NG to LP - RDVOD-RFN Kit #000-5003 Conversion Kit, NG to LP - RDVOD...
Page 36 - Optional Accessories; Fan Kits
39 Radiance Direct Vent /Natural Vent Gas Heater 20004188 Optional Accessories Fan Kits FK26 Fan The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem-perature rises above and falls below a...
Page 37 - BASIC WARRANTY; COMPONENT WARRANTY; IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty,; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
43 Radiance Direct Vent /Natural Vent Gas Heater 20004188 BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the da...
Page 38 - Efficiency Ratings; RDVODRN; CFM Corporation
Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) RDVODRN 60.7 RDVODRP 60.7 RDVODRFN 60.7 RDVODRPN 60.7 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.com CFM Corporation