Vermont Casting RDVOD - Manual

Vermont Casting RDVOD

Vermont Casting RDVOD – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
Page: / 38

Table of Contents:

  • Page 2 – Radiance Direct Vent /Natural Vent Gas Heater; Completion of sale, nor for purpose of resale,; Installation & Operating Instructions
  • Page 3 – Radiance Direct Vent/Natural Vent Gas Heater; Radiance Direct Vent/Natural Vent Stove Dimensions; Attention
  • Page 4 – Installation Requirements; Locating The Stove; Possible stove locations.; Direct Vent System Only; Stardance; Clearance Requirements; Minimum Clearances to Combustible Materials
  • Page 5 – Parallel installation, minimum back and side clear-; Corner installation, minimum corner clearances and; Minimum wall centerline.; Sidewall Clearance; Direct Vent Only
  • Page 6 – Radiance Direct Vent/Natural Vent; Input; Gas Inlet and Manifold Pressures; ment, alteration, service or maintenance; Horizontal Termination -
  • Page 7 – Vent Termination Clearances; NOTE: The restrictor; Vertical vent termination window.; IMPORTANT
  • Page 9 – General Venting Information - Termination Location; Canadian Installations
  • Page 10 – Venting Runs; (Measured from top of the unit before any elbow); NOTE: When venting staight vertical, without any; Termination Clearances; Termination clearances.; Venting Requirements - Natural Vent Only; Vent termination window - Natural Vent ONLY.
  • Page 11 – Venting Requirements and Options -; Approved Vent System Components; Simpson DuraVent Components; Direct vent pipe may be used on the Natural
  • Page 12 – Slide stove back just far enough to access rear leg; Assembly Procedures; Failure to position the parts in accor-; WARNING; Tools Required; Radiance; Carefully tip stove onto back legs. Leave pallet under
  • Page 13 – JUV; Attach the fan rheostat.; Install the Optional Fan; Remove rear shroud.; Fan kit components.; Attach blower assembly and snapstat.
  • Page 14 – Venting System Assembly - Direct Vent; For Canadian installations:; Install the Vent Adapter Pipe; Install the restrictor plate only if required for the vent-; Attach the Inner Vent Assembly to the stove.; attach inner pipe; Connect the inner starter with the next section of; attach inner assy
  • Page 15 – Side Wall Termination Assembly; Discard the inner starter pipe; install outer adpater; dura vent; Simpson DuraVent - install inner adpater pipe.; Vent Opening; Combustible Wall; Locate vent opening.; CFM System
  • Page 16 – For DuraVent pipe only:; Zero Clearance Sleeve; Assemble the wall sleeve and firestop.; measure thru wall; Measure the horizontal length.; install pipe thru wall; Install the horizontal pipe and wall plate parts.
  • Page 17 – Vent Assembly; install snorkel; Snorkel kit installation.; Vent Termination Below Grade; If the; snorkel detail; Use extension brackets to mount snorkel against; install wall terminal; Install the vent terminal.
  • Page 18 – vent thru roof; Roof support and flashing.; Venting System Assembly - Natural Vent; Install firestops and attic insulation shield.
  • Page 19 – Install Log Set; Remove the stove front.; Release the latches to remvoe the glass frame.; Install the Vent Pipe; attach draft hood
  • Page 20 – Install the left and right rear logs and the right log.; Install the right log by engaging hole on the bottom; Connect the Gas Supply Line; Gas connection should be made in ac-; Radiance logs; Completed log installation.; Top View; Lava rock placement.; Radiance logs
  • Page 21 – Use only a thermostat rated for 500 - 750 millivolts.; Install ON/OFF Switch; PILOT; attach switch; Attach switch wires to valve.; Install the Mesh and Grille; THIS APPLIANCE SHOULD BE CON-; In order to connect Natural Gas,; CAUTION; attach switch assy; Attach switch assembly to rear shroud.; Thermostat
  • Page 22 – Operation; Your First Fire; handle holder; When not in use, store handle in the handle holder.; Pilot Assembly location.; To open the front doors, turn handle counterclockwise.; Flame & Temperature Adjustment; Flame adjustment knob for Honeywell valve.; Flame Characteristics; Correct pilot and burner flame patterns.; Pilot flame; SIT Pilot
  • Page 23 – FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting and Operating Instructions; Lighting Instructions; Lighting instructions
  • Page 24 – Troubleshooting / Honeywell #8420 Gas Control System; SYMPTOM
  • Page 25 – comfort valve; Transmitter diagram.; Honeywell; Comfort control valve.
  • Page 26 – Local Path
  • Page 27 – above; Auto Path; below
  • Page 28 – If an Error Code 3 is observed while performing the; Blower; Comfort Valve wiring diagram.
  • Page 29 – All Models; Depress and turn center plunger.; Model; RDVOD, RDVOD with; Table 2. Air Shutter Adjustment; Remove and replace injector orifices.; injector orifice; Conversion to Natural Gas; Table 1. Injector Orifice Size Matrix
  • Page 30 – Maintenance; painted surfaces; Remove the Stove Front.
  • Page 31 – Gasket Replacement; Determine the correct length of gasket by laying it; Inspect the Vent System Annually; glass gasket detail; Wrap the gasket material around the outside edge of; Correct flame pattern.; Release the latches to remove the glass frame.
  • Page 32 – BLK; rdv connections diag.; Schematic Diagram; Wiring Diagrams; On/off switch and optional thermostat circuit.; Used on
  • Page 33 – RDVOD; Manifold Assembly
  • Page 35 – Fuel Conversion Kits
  • Page 36 – Optional Accessories; Fan Kits
  • Page 37 – BASIC WARRANTY; COMPONENT WARRANTY; IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty,; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
  • Page 38 – Efficiency Ratings; RDVODRN; CFM Corporation
Loading the manual

INSTALLER / CONSUMER

SAFETY INFORMATION

20004188 4/06 Rev. 14

PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.

WARNING!

IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY

Installation and service must be
performed by a qualified installer,
service agency or the gas suppler.

WHAT TO DO IF

YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch; do
not use any phone in your building.

Immediately call your gas supplier
from your neighbor’s phone. Follow
the gas supplier’s instructions.

If you cannot reach your gas supplier,
call the fire department.

DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS
OR ANY OTHER APPLIANCE.

This appliance may be installed in an
after market permanently located
manufactured (mobile) home where not
prohibited by local codes.

This appliance is only for use with the
type of gas indicated on the rating plate.

This appliance is not convertible for use
with other gases unless a certified kit is
used.

Radiance
Direct Vent/Natural Vent
Gas Heater

Model RDVOD: 3225 thru 3232,
3350 thru 3354, 3360 thru 3369,
3390 thru 3399

Homeowner’s Installation

and Operating Manual

C E R T I F I E D

DESIGN

C ERTIFIE D

4188

Radiance

cover

4/01

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Radiance Direct Vent /Natural Vent Gas Heater; Completion of sale, nor for purpose of resale,; Installation & Operating Instructions

3 Radiance Direct Vent /Natural Vent Gas Heater 20004188 The Radiance Direct Vent/Natural Vent Room Heater, Model Nos. 3350 thru 3354, 3360 thru 3369 and 3390 thru 3399, is a vented gas appliance listed to the ANSI standard Z21.88b-2002 and CSA-2.33b-2002 for Vented Room Heaters, and CSA 2.17-M91, G...

Page 3 - Radiance Direct Vent/Natural Vent Gas Heater; Radiance Direct Vent/Natural Vent Stove Dimensions; Attention

4 4 Radiance Direct Vent/Natural Vent Gas Heater 20004188 29 ��� " (7.6cm) 31" (7.9cm) 7" Outer Dia. (1.8cm) � ����������� � 4 ��� " (1.2cm) 14 ��� " (3.7cm) ST126 RDV40 dimensions 10/99 � � � � � � � � 28" (711mm) 5" (127mm) 9 ��� " (241mm) 18 ��� " (464mm) Suppl...

Page 4 - Installation Requirements; Locating The Stove; Possible stove locations.; Direct Vent System Only; Stardance; Clearance Requirements; Minimum Clearances to Combustible Materials

5 Radiance Direct Vent /Natural Vent Gas Heater 20004188 Installation Requirements The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEP-TION: Do not derate this appliance for altitude. Main-tai...

Other Vermont Casting Models

All Vermont Casting Other