Page 2 - SAFETY INFORMATION; Carbon Monoxide Poisoning:; Early signs of carbon monoxide; WARNINGS; TABLE OF CONTENTS
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 2 IMPORTANT: Read this owner’s manual carefully andcompletely before trying to assemble, operate, or ser-vice this fireplace. Imp...
Page 3 - Continued; PRODUCT IDENTIFICATION; Figure 1 - Vent-Free Gas Compact Fireplace; Ignitor Button
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 3 3 1. This appliance is only for use with the type of gas indicated onthe rating plate. This appliance is not convertible for us...
Page 4 - ASSEMBLY; WARNING: Always have branch support and; Figure 3 - Assembling Fireplace; ASSEMBLING FIREPLACE; Installing Log; PRODUCT FEATURES; SAFETY PILOT; UNPACKING; Figure 2 - Removing Fireplace Hood; Hood
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 4 ASSEMBLY WARNING: Always have branch support and screen in place before operating fireplace. This pre-vents excessive temperatu...
Page 5 - Figure 4 - Assembling Hood; Assembling Hood; Align screw holes on hood with screw holes on firebox top.; Unusually Tight Construction
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 5 5 Figure 4 - Assembling Hood Hood Tabs Hood Louver Hood Tab Baffle Sheet MetalScrew Firebox Top Assembling Hood 1. Locate four ...
Page 6 - per kw) of the aggregate input rating; per kw) of the aggregate input rating; WARNING: If the area in which the heater may be; AIR FOR COMBUSTION AND VENTILATION
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 6 AIR FOR COMBUSTION ANDVENTILATION Continued Confined and Unconfined Space The National Fuel Gas Code, ANSI Z223.1.3/ NFPA 54 de...
Page 7 - Ventilation Air From Inside Building; Do not provide openings for inlet or outlet air into; WARNING: A qualified service person must in-; INSTALLATION
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 7 7 Figure 6 - Ventilation Air from Outdoors Shown with OptionalMantel OutletAir VentilatedAttic OutletAir InletAir Inlet Air Ven...
Page 8 - Only use; LOCATING FIREPLACE; CAUTION: This fireplace creates warm air cur-; WARNING: Maintain the minimum clearances; When installing fireplace directly on carpeting, tile or other; Vent-free fireplaces add moisture to the air. Although; CHECK GAS TYPE; If desired, purchase a four-sided brass trim kit for built-in
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 8 You can recess firebox into the wall. You can also position fireplacein the optional cabinet or corner mantels. IMPORTANT: Only...
Page 9 - Figure 10 - Rough Opening for Installing in Corner; BUILT-IN FIREPLACE INSTALLATION; CAUTION: If you install the fireplace in a home; Figure 9 - Rough Opening for Installing in Wall; any electrical source at this time.
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 9 9 INSTALLATION Continued 1. Frame in rough opening. Use dimensions shown in Figure 9for the rough opening. If installing in a c...
Page 10 - Mantel Clearances for Built-In Installation; OPTIONAL MANTEL INSTALLATION; Refer to instructions provided with the mantel for assembly; Figure 12 - Minimum Mantel Clearances for Built-In Installation; Mantel Shelf; Figure 11 - Attaching Fireplace to Wall Studs; Nailing Flanges; When finishing your firebox, combustible materials
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 10 INSTALLATION Continued Mantel Clearances for Built-In Installation If placing mantel above built-in fireplace, you must meet m...
Page 11 - Figure 13 - Attaching Brass Trim to Fireplace; Figure 15 - Assembling Brass Trim; Plate; Removing Upper Louver Assembly; Figure 16 - Removing Upper Louver Assembly
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 11 11 Figure 13 - Attaching Brass Trim to Fireplace Figure 14 - Attaching Wood Base to Floor 5. Firmly snap brass trim kit on sho...
Page 12 - Figure 18 - Installing Blower Bracket Assembly; Removing Valve Cover Shield; Do not remove shoulder screw on the left side; Figure 17 - Removing Valve Cover Shield; Installing Blower Assembly; CAUTION: Label all wires prior to disconnection; If you are using a mantel with your heater, use the following
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 12 321 3. Note the wire locations on back of AUTO/OFF/ON switch.The terminals on back of switch are numbered 1, 2, and 3.Carefull...
Page 13 - Figure 19 - Installing Switch Plate to Valve Cover Shield; When switch is in the AUTO position, the; For Built-In Installation; WARNING: A licensed electrician must connect; Follow instructions Removing Valve Cover Shield (page 12), then; Figure 21 - Installing Blower Bracket Assembly
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 13 13 321 Figure 19 - Installing Switch Plate to Valve Cover Shield SwitchPlate Screw Valve CoverShield INSTALLATION Continued 9....
Page 14 - External Regulator; ATTACHING WOOD BASE TO SOLID FLOOR; Floor anchors and mounting screws are in hardware package.; Figure 22 - Folding Anchor; Vent Pointing Down; Extension Cord
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 14 CONNECTING TO GAS SUPPLY WARNING: A qualified service person must con- nect fireplace to gas supply. Follow all local codes. C...
Page 15 - Figure 24 - Gas Connection; Installation Items Needed; • Phillips screwdriver; CAUTION: Avoid damage to regulator. Hold gas; Figure 25 - Removing Log Base Assembly From Fireplace
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 15 15 We recommend that you install a sediment trap in supply line asshown in Figure 24. Locate sediment trap where it is within ...
Page 16 - Pressure Testing Gas Supply Piping System; Correct all leaks at once.; Pressure Testing Fireplace Gas Connections; Open; Figure 27 - Equipment Shutoff Valve; WARNING: Test all gas piping and connections; Make sure control knob of fireplace is in the OFF position.; Equipment Shutoff Valve
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 16 ON POSITION OFF POSITION Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnec...
Page 17 - Figure 30 - Control Knob In The OFF Position; Control Knob; WARNING: You must operate this fireplace with; Thermocouple; FOR YOUR SAFETY; WARNING: If you do not follow these instructions; OPERATING FIREPLACE
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 17 17 LIGHTING INSTRUCTIONS Ignitor Button Figure 30 - Control Knob In The OFF Position Control Knob WARNING: You must operate th...
Page 18 - Shutting Off Fireplace; Shutting Off Burner Only (pilot stays lit); INSPECTING BURNER
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 18 TO TURN OFF GAS TO APPLIANCE The thermostatic control used on this fireplace differs fromstandard thermostats. Standard thermo...
Page 19 - When using the fireplace the first time, the flame will be; Figure 35 - Correct Burner Flame Pattern; WARNING: Turn off fireplace and let cool before; Pilot Assembly; CABINET; Air Passageways; CLEANING AND MAINTENANCE; WARNING: Failure to keep the primary air
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 19 19 BURNER FLAME PATTERN Figure 35 shows a correct burner flame pattern. Figure 36 shows anincorrect burner flame pattern. The ...
Page 20 - WARNING: Turn off and unplug; POSSIBLE CAUSE; All troubleshooting items are listed in; TROUBLESHOOTING
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 20 TROUBLESHOOTING WARNING: Turn off and unplug fireplace and let cool before servic-ing. Only a qualified service personshould s...
Page 21 - REMEDY; nance, page 19) or replace burner orifice; OBSERVED PROBLEM
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 21 21 REMEDY 1. Clean burner (see Cleaning and Mainte- nance, page 19) or replace burner orifice 2. Contact local propane/LP or n...
Page 22 - IMPORTANT
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 22 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply.• Do not try to light any appliance.• Do not touch a...
Page 23 - TECHNICAL SERVICE; When Gas Pressure Is Too Low; REPLACEMENT PARTS; PARTS UNDER WARRANTY; SPECIFICATIONS
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 23 23 TECHNICAL SERVICE You may have further questions about installation, operation, ortroubleshooting. If so, contact DESA Heat...
Page 24 - ILLUSTRATED PARTS BREAKDOWN
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 24 ILLUSTRATED PARTSBREAKDOWN MODELS VMH26TPB (Shown)AND VMH26TNB 12 23 29 40 32 36 38 13 7 8 33 40 11 10 4 7 30 1 3 2 9 17 19 6 ...
Page 25 - PARTS LIST; KEY
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 25 25 PARTS LIST This list contains replaceable parts used inyour fireplace. When ordering parts, fol-low the instructions listed...
Page 26 - Creates the sound of a real burning fire.; ACCESSORIES
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 26 ACCESSORIES Purchase these fireplace accessories from your local dealer. If theycannot supply these accessories call DESA Heat...
Page 27 - OWNER'S REGISTRATION FORM
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 27 27 1. Where will the product be used? ❍ Living/Family Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ ...
Page 28 - Postage; T APE
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 28 2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004 Postage Required T APE TAPE
Page 29 - NOTES
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 29 29 NOTES _______________________________________________________________________________________________ _____________________...
Page 30 - LIMITED WARRANTY; For information about this warranty write:; KEEP THIS WARRANTY; Model; WARRANTY INFORMATION; NOT A UPC
111043-01A F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m F o r m o r e i n f o r m a t i o n , v i s i t w w w . d e s a t e c h . c o m 30 2701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004 www.desatech.com 111043-01Rev. A04/03 LIMITED WARRANTY VENT-FR...