Page 2 - Heat Output, Maximum; SPECIFICATIONS; American Harvest Multifuel Stove); You've purchased one of America's Finest Multifuel Burning
2 USSC Heat Input, Maximum 52,200 BTU/HR Heat Output, Maximum , , , , , 48,280 BTU/HR Heating Capacity 1,200 Sq. Ft 0 Fuel Storage Capacity 60 Lbs. Width 29 in./737mm Height 31 in./787mm 24 in./610mm Depth 28 in./711mm SPECIFICATIONS United States Stove Company ( manufacturer of the American Harvest...
Page 3 - ASSEMBLY; Assembly; 039 PEDESTAL TRIM ASSEMBLY
USSC 3 ASSEMBLY Assembly 1. Unpack unit and make sure all components are included; (4) Legs, and all hardware for installation.2. Fold the corner padding from the carton and lay it on the floor behind the unit. This is used to hold the heater up off the floor to install the legs. Gently tilt the hea...
Page 4 - DISCONNECT THE POWER CORD BEFORE SERVICING THIS STOVE
4 USSC 6039I ASSEMBLY For the following assemblies, we suggest locating the unit near it’s desired location. Depending on installation, you may want to connect the exhaust venting before installing the facade parts.Assembly - Facade (Surround)Remove contents from packaging and make sure you have all...
Page 5 - COMPONENT LOCATION
Page 6 - SAFETY STEPS; permits or inspection guidelines before installing the product.; DISCONNECT THE POWER CORD BEFORE SERVICING THIS STOVE!; BURNING SOLID FUELS
6 USSC Ashes will have to be removed from the stove for proper operation. See cleaning procedure. Your American Harvest stove, due to the nature of solid fuels, will require brief periodic attention. Please do not expect to light your stove and walk away from it. A few moments of adjustment and clea...
Page 7 - FLOOR PROTECTION; INSTALLATION REQUIREMENTS; SHELLED CORN; DO NOT PLACE SUCH FUELS WITHIN THE SPACE HEATER’S
USSC 7 FLOOR PROTECTION The American Harvest Multifuel Stove may be installed on a combustible floor, with proper floor protection, or on a masonry hearth. The hearth or noncombustible floor protector must extend a minimum of (6) inches (152mm)in front and (6) inches (152mm) from each side of the un...
Page 8 - SIDE WALL; BACK WALL
8 USSC CLEARANCES TO COMBUSTIBLES 6039(T) The stove must be installed with the following minimum clearances to side and back wall combustible materials. NOTE: These are minimum clearances to combustible walls established by the testing lab. PARALLEL - A - Sidewall to Top Edge of Unit 8 in./203mm B -...
Page 9 - CLEARANCES TO COMBUSTIBLES 6039I
Page 10 - GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN; DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM
10 USSC GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN • • • •• • • • A UL listed 3” or 4” type “PL” pellet vent exhaust system must be used for installation and attached to the pipe connector provided on the back of the stove. Use a 3” to 4” adapter for 4” pipe. A cap must be used at the termination...
Page 11 - DESIGN GUIDELINES FOR OUTSIDE COMBUSTION AIR CONNECTION; 0 DEGREE BEND TERMINATION; Wind Hood
USSC 11 For installations with horizontal through-the-wall exhaust, it is strongly recommended that the stove combustion air be connected to the outside. If the home is newer or has been tightly insulated, it is required to install outside combustion air. Connection to outside the house is REQUIRED ...
Page 12 - MOBILE HOME INSTALLATION REQUIREMENTS; REQUIREMENTS ARE MANDATORY FOR INSTALLATION IN A MOBILE HOME:; WARNING; DO NOT INSTALL IN SLEEPING ROOM; CAUTION; ROOF MUST BE MAINTAINED.; Check with your local building official as other codes may apply.; INSTALLATION CONFIGURATIONS
12 USSC Note: Where passage through a wall, or partition of combustible construction is desired, the installation shall conform to CAN/CSA -B365 The American Harvest Multifuel Stove Model 6039/6039T may be installed as follows: 1) A freestanding unit The American Harvest Multifuel Stove Model 6039I ...
Page 13 - ’ Minimum
USSC 13 3" PL Vent (12" Long) Inner Wall Thimble Outer Wall Thimble 3" PL Vent (12" Long) 3" PL Tee w/ Cleanout 3" PL Vent (12" Long) 3" PL Vent 90° Elbow 3" PL Vent Termination Cap Note: Always check dimensions on unit before cutting hole in wall 3’ Minimum Verti...
Page 15 - DESIGN GUIDELINES FOR 6039I INSERT INSTALLATION; Alternative Exhaust Venting
USSC 15 DESIGN GUIDELINES FOR 6039I INSERT INSTALLATION INSTALLATION AS A BUILT-IN FIREPLACEA continuous sheet of non-combustible floor protection must be installed underneath the unit to prevent the possibility of embers falling through to the combustible floor. If the floor beneath the unit is of ...
Page 17 - REMOVAL OF BROKEN OR DAMAGED CERAMIC GLASS; CLEANING THE GLASS; GLASS MAINTENANCE, REMOVAL AND REPLACEMENT; GLASS CLIPS
USSC 17 Your American Harvest Multifuel Stove comes to you with the glass door installed in place, ready for use. The glass is surrounded on the edges with a gasket and seated in a glass channel. It is held in place with two (2) clips. REMOVAL OF BROKEN OR DAMAGED CERAMIC GLASS Open the door and lif...
Page 18 - UNDERSTANDING THE CONTROL BOARD; CONTROL PANEL
18 USSC UNDERSTANDING THE CONTROL BOARD CONTROL PANEL Turning the heater OFF/ON, as well as adjustments for the fuel feedrate and room fan speed are performed by pressing the appropriatebutton(s) on the control panel which is located on the lower left-handside of your American Harvest heater. The in...
Page 19 - LIGHTING INSTRUCTIONS
USSC 19 LIGHTING INSTRUCTIONS CAUTION: DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. Before lighting your heater for the first time, make sure that all items are out of the hopper, ash pan and firebo...
Page 20 - MAINTENANCE INSTRUCTIONS; Daily Maintenance; Soot and Flyash - Formation and Need for Removal; DISPOSAL OF ASHES; Disposal of Ashes
20 USSC SPECIAL CLEANING/OPERATIONAL INSTRUCTIONS:After cleaning or when operating the stove, you need to make sure that “both” clean-outs are in their proper position. If left out or placed incor- rectly, the combustion air is effected greatly and the stove will not burn properly. Also, make sure t...
Page 21 - FUEL ADDITIVE; These automatic safety features must not be bypassed; AUTOMATIC SAFETY FEATURES; Weekly Maintenance
USSC 21 FUEL ADDITIVE Chicken Scratch for my Corn Burner?Yes - Crazy as it may sound, ground Oyster Shells, (calcium carbonate) same as fed to chickens, is the ideal additive to promote clean burning, especially when the Corn Fuel is extra high in starch. And it’s available at your local Feed and Se...
Page 22 - CIRCUIT BOARD FUNCTIONS
22 USSC CIRCUIT BOARD FUNCTIONS Draft Fan Agitator Auger Room Fan Automatic Shutdown Normal Operation COMPONENT OPERATION START OPERATION END START-UP SEQUENCE OF EVENTS Once the control panel is turned to on, a timer begins that will start, stop and continue operation of the American Harvest as a p...
Page 23 - ERROR CODES and DISPLAY INDICATORS
USSC 23 ERROR CODES and DISPLAY INDICATORS CAUTION: When performing any internal electrical maintenance• Moving parts inside of the cabinet may cause injury. Do not operate unit with panels removed or open.• HOT parts. Do not operate the unit with panel open. • Risk of electric shock. Disconnect pow...
Page 24 - TROUBLE SHOOTING; Unplug stove before performing any maintenance; PROBLEM; CAUSE: Auger stops turning
24 USSC TROUBLE SHOOTING NOTE: Negative pressure in a home is a serious issue. All American Harvest appliances should be installed with the optional fresh air kit (69FAK). Unplug stove before performing any maintenance PROBLEM CAUSE: Too rich air/fuel mixture ? Fire burns with a lazy, orange flamean...
Page 25 - WIRING DIAGRAM
Page 31 - Notes
Page 32 - THE PART DESCRIPTION; HOW TO ORDER REPAIR PARTS; United States Stove Company
32 USSC THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPEND-ABLE SERVICE FROM YOUR AMERICAN HARVEST, AND EN-ABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFER-ENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBERWHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER...