US Stove Company 6039I – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Heat Output, Maximum; SPECIFICATIONS; American Harvest Multifuel Stove); You've purchased one of America's Finest Multifuel Burning
- Page 3 – ASSEMBLY; Assembly; 039 PEDESTAL TRIM ASSEMBLY
- Page 4 – DISCONNECT THE POWER CORD BEFORE SERVICING THIS STOVE
- Page 5 – COMPONENT LOCATION
- Page 6 – SAFETY STEPS; permits or inspection guidelines before installing the product.; DISCONNECT THE POWER CORD BEFORE SERVICING THIS STOVE!; BURNING SOLID FUELS
- Page 7 – FLOOR PROTECTION; INSTALLATION REQUIREMENTS; SHELLED CORN; DO NOT PLACE SUCH FUELS WITHIN THE SPACE HEATER’S
- Page 8 – SIDE WALL; BACK WALL
- Page 9 – CLEARANCES TO COMBUSTIBLES 6039I
- Page 10 – GUIDELINES FOR EXHAUST VENTING SYSTEMS DESIGN; DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM
- Page 11 – DESIGN GUIDELINES FOR OUTSIDE COMBUSTION AIR CONNECTION; 0 DEGREE BEND TERMINATION; Wind Hood
- Page 12 – MOBILE HOME INSTALLATION REQUIREMENTS; REQUIREMENTS ARE MANDATORY FOR INSTALLATION IN A MOBILE HOME:; WARNING; DO NOT INSTALL IN SLEEPING ROOM; CAUTION; ROOF MUST BE MAINTAINED.; Check with your local building official as other codes may apply.; INSTALLATION CONFIGURATIONS
- Page 13 – ’ Minimum
- Page 15 – DESIGN GUIDELINES FOR 6039I INSERT INSTALLATION; Alternative Exhaust Venting
- Page 17 – REMOVAL OF BROKEN OR DAMAGED CERAMIC GLASS; CLEANING THE GLASS; GLASS MAINTENANCE, REMOVAL AND REPLACEMENT; GLASS CLIPS
- Page 18 – UNDERSTANDING THE CONTROL BOARD; CONTROL PANEL
- Page 19 – LIGHTING INSTRUCTIONS
- Page 20 – MAINTENANCE INSTRUCTIONS; Daily Maintenance; Soot and Flyash - Formation and Need for Removal; DISPOSAL OF ASHES; Disposal of Ashes
- Page 21 – FUEL ADDITIVE; These automatic safety features must not be bypassed; AUTOMATIC SAFETY FEATURES; Weekly Maintenance
- Page 22 – CIRCUIT BOARD FUNCTIONS
- Page 23 – ERROR CODES and DISPLAY INDICATORS
- Page 24 – TROUBLE SHOOTING; Unplug stove before performing any maintenance; PROBLEM; CAUSE: Auger stops turning
- Page 25 – WIRING DIAGRAM
- Page 31 – Notes
- Page 32 – THE PART DESCRIPTION; HOW TO ORDER REPAIR PARTS; United States Stove Company
USSC
1
851621E
MULTIFUEL STOVE
6039, 6039I, 6039T
OWNER’S MANUAL
Installation - Operation - Maintenance Instructions - Repair Parts
READ THIS ENTIRE MANUAL, THOROUGHLY, BEFORE ATTEMPTING TO INSTALL AND/OR
BURN YOUR NEW AMERICAN HARVEST CORN AND PELLET MULTI-FUEL STOVE. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURIES
OR EVEN DEATH.
SAVE THESE INSTRUCTIONS
UNITED STATES STOVE COMPANY GRANTS NO WARRANTY, IMPLIED OR STATED,
FOR THE INSTALLATION OR MAINTENANCE OF THE STOVE AND ASSUMES NO
RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).
UNITED STATES STOVE COMPANY - 227 INDUSTRIAL PARK ROAD-SOUTH PITTSBURG, TN. 37380
TECHNICAL ASSISTANCE (423) 837-2100 - (423) 837-2109 FAX
Safety Notice: If this stove is not properly installed, a house fire may result.
For your safety, follow the installation directions. Contact local building or fire officials
about restrictions and installation requirements peculiar to your area. Do Not Plug
this appliance into an electrical outlet before reading and understanding all operations
and always unplug the unit before attempting any work or maintenance. Do not
connect this stove to any chimney flue already serving another appliance. Carefully
observe and maintain all clearances to combustibles.
A note about fuel: Use only dried shelled corn with a moisture content of 14%
or less (11 to 12% provides the best results); any pellet fuel used should have
an ash content of 1% or less. If not, efficiency will suffer, and your warranty may be
voided.
Your American Harvest Corn/Pellet Stove operates on a negative pressure. Therefore,
all venting connections (elbows, T-pipe) must be sealed and airtight.
Use Hi-Temp silicone at each joint or connection.
K e e p i n g
K e e p i n g
K e e p i n g
K e e p i n g
K e e p i n g
A m e r i c a W a r m S i n c e
A m e r i c a W a r m S i n c e
A m e r i c a W a r m S i n c e
A m e r i c a W a r m S i n c e
A m e r i c a W a r m S i n c e
1 8 6 9
1 8 6 9
1 8 6 9
1 8 6 9
1 8 6 9
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 USSC Heat Input, Maximum 52,200 BTU/HR Heat Output, Maximum , , , , , 48,280 BTU/HR Heating Capacity 1,200 Sq. Ft 0 Fuel Storage Capacity 60 Lbs. Width 29 in./737mm Height 31 in./787mm 24 in./610mm Depth 28 in./711mm SPECIFICATIONS United States Stove Company ( manufacturer of the American Harvest...
USSC 3 ASSEMBLY Assembly 1. Unpack unit and make sure all components are included; (4) Legs, and all hardware for installation.2. Fold the corner padding from the carton and lay it on the floor behind the unit. This is used to hold the heater up off the floor to install the legs. Gently tilt the hea...
4 USSC 6039I ASSEMBLY For the following assemblies, we suggest locating the unit near it’s desired location. Depending on installation, you may want to connect the exhaust venting before installing the facade parts.Assembly - Facade (Surround)Remove contents from packaging and make sure you have all...