Page 2 - NOTICE
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU NOTICE SpectraLink Corporation has prepared this document for use by SpectraLink personnel and clients. The drawings and specifications contained herein are the property of SpectraLink and shall be neither reproduced in w...
Page 3 - Note concerning the Master Control Unit:
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Note concerning the Master Control Unit: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonab...
Page 4 - UL Information; Never install telephone wiring during a lightning storm.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU UL Information This symbol on the nameplate means the product is listed by Underwriter’s Laboratories, Inc. It is designed and manufactured to meet rigid U.L. safety standards against X-radiation, fire, casualty, and elec...
Page 5 - FCC Information
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU FCC Information The Master Control Unit Complies with Part 68, FCC Rules FCC Registration Numbers: Link 3000: IYGUSA-7385Q-PX-T Ringer Equivalence: Link 3000: 0.3B SpectraLink Corporation Link 3000 Made in the USA This eq...
Page 6 - Warranty and Repair Service Center:
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Industry Canada (IC) Notice Notice: The Industry Canada (IC) label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational, and safety requireme...
Page 7 - Table of Contents
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Table of Contents 1. ABOUT THIS DOCUMENT 8 1.1 Contacting SpectraLink 8 1.2 Icons Used in this Document 8 1.3 Remote Installation Overview 9 1.4 Remote Installation Steps (Overview) 10 2. SITE PREPARATION 11 2.1 Required ...
Page 8 - About This Document; SpectraLink; The Hotline is open Monday; Icons Used in this Document; This manual uses the following icons and conventions.; Caution! Follow these instructions carefully to avoid danger.; NORM
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 1. About This Document This document explains installation of the SpectraLink Link Wireless Telephone System (Link WTS, MCS300) Remote T1 Module. The installation process connects the Link 3000 MCU Primary Shelf in one lo...
Page 9 - Remote Installation Overview
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 1.3 Remote Installation Overview Networking the Link WTS allows installation of expansion shelves at remote locations. T1 circuits are used to provide the connection from the System Controller shelf to each Remote Expansi...
Page 10 - Shelves at the site.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 1.4 Remote Installation Steps (Overview) Follow these steps to install the T1 Remote Module. Detailed instructions for each of these steps are contained in this document and other relevant documents in the Link 3000 MCU S...
Page 11 - Preparation; Link WTS – Link 3000 MCU: Installation; Required Materials Provided by Customer; Installation
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 2. Site Preparation The following steps must be completed before installing the system hardware. If the steps are not already completed refer to each individual section for details. 1. At the local site, install and test ...
Page 12 - T1 Configuration Requirements
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 2.2 T1 Configuration Requirements T1 circuits will connect expansion shelves directly to the System Controller shelf via the SpectraLink provided Intershelf Junction Panel. The Intershelf Junction Panel is always co-locat...
Page 13 - Components
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 2.3 Check Components The following items should be at the installation site. Link 3000 MCU Expansion Shelves – (MCS300) – the number of shelves varies depending on the size of the system. Grounding Strap – (in the Link WT...
Page 14 - Install T1 Remote Module at Local Site; or; Connect Intershelf Junction Panel
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 3. Install T1 Remote Module at Local Site Before installing the hardware at the remote site, the Primary shelf at the local site must have a T1 Remote Module (CRC301) installed. Install one Remote Module for each remote s...
Page 15 - Network Clocked T1 Facilities; Connect T1 Facilities
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Network Clocked T1 Facilities If the T1 facilities are Network Clocked, one T1 Remote Module must be designated as the Master Clock Source. Connect the Sync IN port on this T1 Remote Module to AUX port A on the Intershelf...
Page 17 - Install System at Remote Site; Site; Location chosen for the shelves is adequate.; Shelves; Rack Mount; Link WTS – Link; keyhole openings in the back of the shelf.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 4. Install System at Remote Site 4.1 Survey Site Check the site to be sure pre-installation work has been completed correctly. This includes: • Location chosen for the shelves is adequate. • Rack (if rack mounted) is prop...
Page 18 - Do not install cards until power is connected.; Connect Power to Shelves; Cards; Install T1 Remote Module
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Do not install cards until power is connected. 4.3 Connect Power to Shelves SpectraLink recommends that a licensed electrician install the –48V DC power supply and connect power to the shelves. See Link WTS – Link 3000 MC...
Page 19 - Fully Loaded Remote Expansion Shelf; Connect Cables to T1 Remote Module; Connect T1 Remote Module to Expansion Shelf Controller; Connect Multiple Remote Shelves
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU DISABLE ALARM 1 2345 CONN A NORMAL DISABLE ALARM 1 2345 CONN A NORMAL ALARM 1 2345 RS-232 (RJ45) (RJ45) SC/A SC/B 1 2 3 4 5 6 7 8 9 10 11 12 DISABLE ALARM 1 2345 CONN A NORMAL DISABLE ALARM 1 2345 CONN A NORMAL DISABLE AL...
Page 21 - Connect Demarc Block RJ-21 Cables to Interface
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 4.7 Connect Demarc Block RJ-21 Cables to Interface Modules Connect the male RJ-21 connector from the appropriate demarcation block to the designated RJ-21 connector ( A or B ) on each Interface Module. Secure the cables u...
Page 22 - Configure Remote System; Configure Remote Shelf
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 5. Configure Remote System Use the Operator’s Console to enter configuration information for the Remote Expansion Shelves. 5.1 Configure Remote Shelf 1. From the Operator’s Console, select F1 , Supervisor State Display . ...
Page 23 - Master Clock Configuration; to save the information.; System
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 5.2 Master Clock Configuration If the T1 facilities are Network Clocked, one shelf must be designated as the Master Clock Source. 1. From the Operator’s Console, select F8, Configuration Display and Administration . The f...
Page 24 - Certification; Operator’s Console
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 6. Site Certification The installer should not leave the site before contacting SpectraLink to perform remote install verification. Before leaving the location where the Primary Shelf is installed, the installer must comp...
Page 25 - Forms; This section contains the following forms:
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 7. Installation Forms This section contains the following forms: Base Station Locations Extension Assignments Site Preparation Checklist Customer Acceptance Form Copy these forms as needed. Be sure to maintain completed f...
Page 26 - Base Station Location Form
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 7.1 Base Station Location Form Shelf Number: ________ Interface Module: ________ Base Station # Location (e.g.: building, floor #, detailed description) Interface Module Circuit # Base Station 1 1 Base Station 2 2 Base St...
Page 27 - Extension Assignments Worksheet
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 7.2 Extension Assignments Worksheet Shelf: _______ Interface Module: _______ Phone # Ext. # Name Interface Module Circuit # Comment Wireless Telephone Serial # Phone 1 1 Phone 2 2 Phone 3 3 Phone 4 4 Phone 5 5 Phone 6 6 P...
Page 28 - Site Preparation Checklist; Please be sure the following items are completed.
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 7.3 Site Preparation Checklist If upon arrival the SpectraLink installer determines that the pre-installation work has not been completed correctly, the installer has two options: 1) the installer can leave the site and r...
Page 29 - Customer Acceptance Form
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU 7.4 Customer Acceptance Form Customer Name: _______________________________________________________________________ Lease number (if applicable):___________________ Schedule number (if applicable):_______________ This doc...
Page 30 - Index
SpectraLink Corporation T1 Remote Module Installation Link WTS – Link 3000 MCU Index Base station location form, 27 Cards Installing, 15, 19 Channel Service Unit, 13 Configuration Requirements T1, 13 CSU, 13 Customer Acceptance Form , 30 Customer Support Hotline, 8 Demarc block, 22 Diagram, Remote I...