Page 4 - Legal notices; Information on the safety notices and correct usage
SCALANCE W788-xPRO / W74x-1PRO/RR 4 A5E02280448-02, Release 11/2008 Legal notices Information on the safety notices and correct usage Concept of the warning notices This manual contains notices which you should observe to ensure your own personal safety, as well as to protect the product and connect...
Page 7 - Table of contents
SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 7 Table of contents Introduction .............................................................................................................. 9 Information on the Operating Instructions (compact) SCALANCE W788- xPRO/RR and W74x-1PRO...
Page 9 - Introduction; Information on the Operating Instructions (compact)
Introduction SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 9 Introduction Information on the Operating Instructions (compact) SCALANCE W788-xPRO/RR and W74x-1PRO/RR Validity of the Operating Instructions (compact) These Operating Instructions (compact) cover the following product...
Page 10 - Type designations
Introduction SCALANCE W788-xPRO / W74x-1PRO/RR 10 A5E02280448-02, Release 11/2008 Type designations Abbreviations used The information in the manuals for the SCALANCE W-700 product family often applies to more than one product variant. In such situations, the designations of the products are shorten...
Page 13 - Description; Components of the product; LED displays
Description SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 13 Description Components of the product The following parts belong to the consignment of the SCALANCE W788-xPRO/RR or W74x-1PRO/RR: ● SCALANCE W788-xPRO/RR or W74x-1PRO/RR ● 2 OMNI antennas ANT795-4MR ● 1 IE IP 67 hybrid ...
Page 17 - Reset button
Description SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 17 Reset button Functions of the reset button The reset button is on the rear of the device below the sealing screw directly beside the C-PLUG and has several functions: ● Restart of the device To restart the device, press...
Page 19 - Mounting; Securing the housing
Mounting SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 19 Mounting Securing the housing Grounding terminal WARNING To operate the SCALANCE W788 safely, the housing must make contact with a chassis ground cable. Do not use the SCALANCE W788 without a ground cable connected. The gr...
Page 21 - Drilling template for the SCALANCE W788-xPRO/RR
Mounting SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 21 Drilling template for the SCALANCE W788-xPRO/RR and SCALANCE W74x-1PRO/RR Drill holes for wall mounting 125 115 4 80 90 5 5
Page 23 - Connecting up; Connectors for external antennas and power supply
Connecting up SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 23 Connecting up Connectors for external antennas and power supply Hybrid female connector and M12 male connector The SCALANCE W788-xPRO / W788-xRR / W74x-1xx is attached to Ethernet via a hybrid socket on the front of t...
Page 26 - Replacing the C-PLUG
Connecting up SCALANCE W788-xPRO / W74x-1PRO/RR 26 A5E02280448-02, Release 11/2008 Replacing the C-PLUG Procedure Follow the steps below to replace the C-PLUG of a SCALANCE W788-xPRO/RR or W74x-1PRO/RR: Note In terms of the C-PLUG, the WLAN devices work in two modes: ● Without C-PLUG The device stor...
Page 27 - Assembling an IE hybrid cable 2 x 2 + 4 x 0.34 with an
Connecting up SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 27 Assembling an IE hybrid cable 2 x 2 + 4 x 0.34 with an IE IP 67 hybrid connector Procedure Remove the two inner shells of the universal sealing ring to adapt it to the diameter of the hybrid cable. Push the bushing, w...
Page 32 - Fitting the IE FC TP standard cable 4 x 2 GP to an IE
Connecting up SCALANCE W788-xPRO / W74x-1PRO/RR 32 A5E02280448-02, Release 11/2008 Fitting the IE FC TP standard cable 4 x 2 GP to an IE IP 67 hybrid connector Procedure Remove the two inner shells of the universal sealing ring to adapt it to the diameter of the hybrid cable. Push the bushing, washe...
Page 37 - Pinning of the M12 male connector
Connecting up SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 37 Pinning of the M12 male connector Power supply over the M12 connector The M12 male connector on the front of the SCALANCE W7xx has the following pinning: Pin Function Pin 1 24 V DC Pin 2 -- Pin 3 Ground Pin 4 -- Light...
Page 41 - Suitable antenna cables and antennas for SCALANCE
Connecting up SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 41 Suitable antenna cables and antennas for SCALANCE W-700 Antenna connector: N-Connect/R-SMA connecting cable The N-Connect/R-SMA male/male flexible connecting cable is available as an accessory for direct connection of...
Page 43 - Cabling for power supply and Ethernet
Connecting up SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 43 Cabling for power supply and Ethernet Suitable cables The following cables are available for connecting a SCALANCE W788-xPRO/RR or SCALANCE W74x-1PRO/RR to the power supply and Ethernet: ● IE hybrid cable 2 x 2 + 4 x ...
Page 45 - Technical specifications; Technical specifications for the SCALANCE W788-
Technical specifications SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 45 Technical specifications Technical specifications for the SCALANCE W788- xPRO/RR and W74x-1PRO/RR Device variants The technical specifications of the ● SIMATIC NET SCALANCE W744-1PRO ● SIMATIC NET SCALANCE ...
Page 50 - SCALANCE W788 dimension drawing
Technical specifications SCALANCE W788-xPRO / W74x-1PRO/RR 50 A5E02280448-02, Release 11/2008 SCALANCE W788 dimension drawing Front view and top view SCALANCE W788 62 79 115 s 35 SCALANCE W788-2PRO NEC CLASS 2 S VP V9051798 00-0E-8C-95-E8-07 M3 M2 L3 L2 X1P1 FOR LAN ONLYL2 24V L3 48V WARNING:EXPLOSI...
Page 52 - Technical specifications ANT795-4MR
Technical specifications SCALANCE W788-xPRO / W74x-1PRO/RR 52 A5E02280448-02, Release 11/2008 Technical specifications ANT795-4MR Mechanical characteristics Connector R-SMA male for connection to SCALANCE W78x or SCALANCE W74x Cover material Polycarbonate Silicone-free Electrical characteristics Fre...
Page 53 - Dimension drawing ANT795-4MR
Technical specifications SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 53 Dimension drawing ANT795-4MR 21,2 34,6 148 13 6
Page 54 - Permitted antennas
Technical specifications SCALANCE W788-xPRO / W74x-1PRO/RR 54 A5E02280448-02, Release 11/2008 Permitted antennas Accessories for SCALANCE W-700 Note When you select an antenna, keep in mind the national approvals for your SCALANCE W7xx. Characteristics Type Frequency / GHz Antenna gain / dBi Impedan...
Page 57 - Certification; Approvals for the SCALANCE W788-xPRO/RR and
Certification SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 57 Certification Approvals for the SCALANCE W788-xPRO/RR and 74x-1PRO/RR CE conformity The products SIMATIC NET SCALANCE W788-1PRO SIMATIC NET SCALANCE W788-2PRO SIMATIC NET SCALANCE W788-1RR SIMATIC NET SCALANCE W788-2R...
Page 63 - National approvals SCALANCE W-700
Certification SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 63 Note The specified approvals apply only when the corresponding mark is printed on the product. 사용자안내문(제 5 조제 1 항제 1 호관련) 기 종 별 사 용 자 안 내 문 A 급 기기 (업무용 방송통신기기) (업무용 방송통신기기) 기기이오니 판매자 또는 사용자는 이 점을 주의하시기 바라며, 가정외의 지역에서 사...
Page 71 - MIC
Certification SCALANCE W788-xPRO / W74x-1PRO/RR A5E02280448-02, Release 11/2008 71 Country Mode CH MHz PWR (EIRP) Use 11b 11g g-Turbo 1 - 13 2412 - 2472 100 mW Indoor + outdoor 11a TPC 36 - 48 5180 - 5240 60 mW Indoor only 36 - 64 5180 - 5320 200 mW Indoor only South Africa 11h DFS+TPC 100 - 140 550...