Page 3 - Note; Installation Considerations; ANGER; AUTION
3 Danger This symbol indicates the presence of dangerous voltage within and outside the product enclosure that may constitute a risk of electric shock, serious injury or death to persons if proper precautions are not followed. Caution This symbol alerts the user to the presence of hazards that may c...
Page 5 - Available Options; Before You Begin
© 2007 Schneider Electric. All rights reserved. 5 ION8800 Models Available Options I/O Options Before You Begin Before installing the meter, familiarize yourself with the steps in this guide and read the safety precautions presented on the “Installation Considerations” page. Feature Set Description ...
Page 6 - Meter Overview
6 © 2007 Schneider Electric. All rights reserved. Meter Overview Navigation Buttons Meter Front (Cover Closed) Meter Back Cover Seal Meter Front (Cover Open) Navigation Buttons Battery Cover Display Sealed Buttons Optical Communications Port varh Pulsing Port Wh Pulsing Port Cover Seal varh Pulsing ...
Page 7 - Front Panel Button Functions; Meter Labels
© 2007 Schneider Electric. All rights reserved. 7 Front Panel Button Functions ALT / ENTER : Press this button once to enter ALT mode. Press and hold to enter Setup mode. In Setup mode, press this button to accept changes. NAVIGATION : Press the UP / DOWN arrow buttons to highlight menu items, or in...
Page 8 - Unit Dimensions
8 © 2007 Schneider Electric. All rights reserved. Unit Dimensions Meter dimensions conform to DIN standard 43862. 38.4 mm (1.51“) 260.0 mm (10.24“) Front View of Meter Side View of Meter Front of Rack View 132.2 mm (5.21“) 202.1 mm (7.96“) 482.0 mm (18.98“) to fit 19 inch rack 57.2 mm (2.25“) 461.0 ...
Page 9 - Essailec Connections; Order Options B/C Circuit & Pinout Diagrams
© 2007 Schneider Electric. All rights reserved. 9 Essailec Connections Voltage, current, power supply, I/O and communication connections are made via the Essailec connector on the rear of the meter. Meters can be ordered with multiple connector configurations. Order Options B/C Circuit & Pinout ...
Page 10 - Order Option A Circuit & Pinout Diagrams
10 © 2007 Schneider Electric. All rights reserved. Order Option A Circuit & Pinout Diagrams Meter Rack A B C D E Cod e 15 C ode 17 Cod e 1 5 Cod e 1 3 Cod e 07 C ode 05 Cod e 03 C ode 01 This pinout drawing details the various pins on the meter side of the connector. The table below maps the pin...
Page 11 - Order Options A/B/C Essailec Connector Arrangement
© 2007 Schneider Electric. All rights reserved. 11 Order Options A/B/C Essailec Connector Arrangement Meter Port Essailec Connector Pin Description Current Measurement Inputs I11 A01 standard I12 A1 standard I21 A02 standard I22 A2 standard I31 A03 standard I32 A3 standard I41 A04 optional I42 A4 op...
Page 12 - Order Options D/E Circuit & Pinout Diagrams
12 © 2007 Schneider Electric. All rights reserved. Order Options D/E Circuit & Pinout Diagrams A B C D Cod e 15 C ode 15 C ode 15 C ode 07 Cod e 03 C ode 05 Meter Rack This pinout drawing details the various pins on the meter side of the connector. The table below maps the pins to their correspo...
Page 13 - Order Options D/E Essailec Connector Arrangement; Step 1: Mount the Meter; Meter Batter y Considerations
© 2007 Schneider Electric. All rights reserved. 13 Order Options D/E Essailec Connector Arrangement Step 1: Mount the Meter Meter Batter y Considerations The meter’s battery life expectancy depends on both temperature and the amount of time the meter is without power. For typical installations, the ...
Page 14 - Installation
14 © 2007 Schneider Electric. All rights reserved. Environmental Specifications (IEC62052-11) Installation D ANGER Do not power up the meter until the ground terminal is connected -- risk of electric shock. 1. Connect the ground terminal on the rear of the meter to a good earth ground on the rack, u...
Page 15 - Form C Digital Output: Mechanical Alarm Relay
© 2007 Schneider Electric. All rights reserved. 15 Step 2: Wire the Digital I/O Form C Digital Output: Mechanical Alarm Relay Form C Digital Output: Solid State Relay Outputs DO1 - DO4 Form A Digital Outputs: Solid State Relay Outputs DO5 - DO12 Digital Inputs: Solid State DI1 - DI3 C AUTION Field H...
Page 16 - Step 3: Wire the Voltage and Current Inputs; Voltage Inputs
16 © 2007 Schneider Electric. All rights reserved. Step 3: Wire the Voltage and Current Inputs Voltage Inputs Current Inputs: High Current Option Current Inputs: Low Current Option N OTE The appropriate Volts Mode setting is included with each wiring diagram. Refer to Step 7 to learn how to configur...
Page 17 - LINE
© 2007 Schneider Electric. All rights reserved. 17 4-Wire Wye, 3-Element, Direct Connection Diagram 288 V L-N / 500 V L-L max.VOLTS MODE = 4W-Wye 4-Wire Wye, 3-Element, 3 PTs Connection Diagram Use PTs for voltages over 288 V L-N / 500 V L-L.Wye (Star) wiring for PT primaries and secondaries.VOLTS M...
Page 19 - Single Phase Connection Diagram
© 2007 Schneider Electric. All rights reserved. 19 3-Wire Delta, 2½-Element, 2 PTs & 3 CTs Use PTs for voltages over 500 V L-LVOLTS MODE = Delta Single Phase Connection Diagram 288 V L-N / 500 V L-L max. Use PTs for higher voltages.VOLTS MODE = Single Using Potential Transformers LINE LOAD LINE ...
Page 20 - Step 4: Wire the Communications
20 © 2007 Schneider Electric. All rights reserved. Step 4: Wire the Communications ION8800 meters are equipped with one standard optical port. Other communications ports are available as options.The Communications module cover plate (found on the back of the meter) should never be removed unless a c...
Page 21 - Ethernet TCP/IP Ser vice Ports; Internal Modem Connection (COM4 optional module)
© 2007 Schneider Electric. All rights reserved. 21 Ethernet Connections (optional module) 10Base-T 10Base-FL (Fiber) N OTE Ethernet connection should be made to either the Fiber port or RJ45 port, not both, or communications conflicts may result. Ethernet TCP/IP Ser vice Ports Internal Modem Connect...
Page 22 - Step 5: Wire the Power Supply; Single Phase Power Supply; Step 6: Power Up the Meter; Step 7: Set Up the Meter Using the Front Panel
22 © 2007 Schneider Electric. All rights reserved. Step 5: Wire the Power Supply ION8800 meter power supply connections are found on the Essailec connector. Single Phase Power Supply Step 6: Power Up the Meter D ANGER Before you apply power to the meter, ensure that ground is securely connected and ...
Page 26 - Step 8: Verify Meter Operation; Phasor Diagrams; DELTA phasors for UNITY Power Factor (resistive load)
26 © 2007 Schneider Electric. All rights reserved. The following table lists all settings that can be configured using the ALT CONFIG menu (not available when meter cover is sealed). 1 After a meter is unlocked, it automatically relocks if you do not perform any configuration for 30 minutes. This fu...
Page 29 - Step 9: View Meter Data; NORM mode
© 2007 Schneider Electric. All rights reserved. 29 Step 9: View Meter Data NORM mode Use the Up and Down buttons to scroll through NORM mode display screens. ALT mode Press the Alt/Enter button once for ALT display modes. Press the Up or Down buttons to scroll through displays. NORM Screen Contents ...
Page 30 - TEST Mode
30 © 2007 Schneider Electric. All rights reserved. N OTE PB = Previous Billing period. TEST Mode To Enter TEST Mode N OTE The meter always returns to NORM mode after exiting TEST mode. TOU Display Screen Contents TOU Energy by Rate kWh delivered values for each TOU rate kW Peak Demand Maximum kW del...
Page 31 - Replacing the Battery; To replace the batter y
© 2007 Schneider Electric. All rights reserved. 31 Replacing the Battery The battery in the ION8800 meter keeps the real time clock running when supply power is lost. Replace the battery if the meter has been stored for an extended period of time without power (longer than two years). If the meter w...
Page 32 - Meter Security; Hardware Locked Security Option; Meter Seals
32 © 2007 Schneider Electric. All rights reserved. Meter Security Security features depend on the meter ordering options. See below. All ION8800 meters Standard security includes traditional anti-tamper mechanical sealing points on the meter case and cover. ION8800 meters with Hardware Locked Securi...