Page 4 - Overview; About the UPS; Safety; Product Overview; Front panel
1 Smart-UPS X-Series Operation Overview About the UPS The APC ® by Schneider Electric Smart-UPS ® X-Series is a high performance Uninterruptible Power Supply (UPS). It provides protection for electronic equipment from utility power blackouts, brownouts, sags, and surges; small utility fluctuations a...
Page 5 - Specifications; Operating Conditions; Installation; UPS; Temperature; Humidity
Smart-UPS X-Series Operation 2 Specifications Operating Conditions This unit is intended for indoor use only. Select a location sturdy enough to support the weight of the unit and External Battery Packs (XLBP). Do not operate the UPS where there is excessive dust, or the temperature or humidity are ...
Page 6 - Operation; Connect Equipment to the UPS; Do; Basic Connections; External Battery Pack connector:
3 Smart-UPS X-Series Operation Operation Connect Equipment to the UPS Note: The UPS will charge to 90% capacity in the first three hours of normal operation. Do not expect full battery run capability during this initial charge period. 1. Connect equipment to the outlets on the rear panel of the UPS....
Page 7 - Display Interface; Standard Menus; Menu; APC by Schneider
Smart-UPS X-Series Operation 4 Display Interface Overview Using the display interface Use U P and D OWN to scroll through the main menu options. Press E NTER to view the sub-menus under each main menu option. Press E SCAPE to exit a sub-menu and return to a main menu. Standard Menus The Standard men...
Page 8 - Advanced Menus
5 Smart-UPS X-Series Operation Advanced Menus The Advanced menus provide additional options for the UPS and are available only if the display interface is configured to use the Advanced Menus. About Display information about this unit:• Unit model number• Serial number• Battery installation date• Su...
Page 9 - Configuration; UPS Settings; General Settings
Smart-UPS X-Series Operation 6 Configuration UPS Settings Start-up Settings Configure these settings at initial start-up, using the display interface or APC PowerChute ® software. Note: During start-up, use the display interface to configure these settings. If nothing is selected, the until will use...
Page 10 - Controllable Outlet Groups; Function
7 Smart-UPS X-Series Operation Controllable Outlet Groups Overview The rear panel of the UPS has multiple outlets, some are grouped into Controllable Outlet Groups, all others are the UPS outlets. All of these groups can be configured to turn off, turn on, shut down, and reboot connected equipment, ...
Page 11 - Model-specific Controllable Outlet Groups
Smart-UPS X-Series Operation 8 Model-specific Controllable Outlet Groups 750VA, 120 V and 230 V. 1000 VA, 120 V and 230 V. 1500 VA, 120 V and 230 V. Controllable Outlet Group(s) UPS outlets s u 04 36 a s u 043 8a su 0 4 3 5 a s u 04 37 a s u 04 88 a s u 048 7a
Page 12 - Using the Controllable Outlet Groups and UPS outlets; Customize the Controllable Outlet Groups and the UPS outlets; Control
9 Smart-UPS X-Series Operation Using the Controllable Outlet Groups and UPS outlets The UPS outlets function as a master switch. They turn on first when power is applied, shut off last when there is a power outage and battery run-time has been exhausted. The UPS outlets must be turned on for the Con...
Page 13 - Network Management Card Settings
Smart-UPS X-Series Operation 10 Network Management Card Settings These settings are available only on units that have a Network Management Card (NMC) and are set in the factory. These settings can only be modified using an external interface, like the NMC web interface. • NMC IP Address Mode • NMC I...
Page 14 - Emergency Power Off; EPO Overview; Normally open contacts
11 Smart-UPS X-Series Operation Emergency Power Off EPO Overview The Emergency Power Off (EPO) option is a safety feature that will immediately disconnect all connected equipment from utility power. The UPS will immediately shut down and will not switch to battery power. The UPS must be manually re-...
Page 15 - Troubleshooting
Smart-UPS X-Series Operation 12 Troubleshooting Problem and Possible Cause Solution The UPS will not turn on or there is no output The unit has not been turned on. Press the ON button once to turn on the UPS. The UPS is not connected to utility power. Ensure that the power cable is securely connecte...
Page 16 - The replace battery LED is illuminated; The display interface has a Site Wiring Fault message
13 Smart-UPS X-Series Operation All indicators are illuminated and the UPS is plugged into a wall outlet The UPS has shut down and the battery has discharged from an extended outage. None. The UPS will return to normal operation when the power is restored and the battery has a sufficient charge. The...
Page 17 - Service and Support; Transport the UPS; APC Worldwide Customer Support
Smart-UPS X-Series Operation 14 Service and Support Service If the UPS requires service, do not return it to the dealer. Follow these steps: 1. Review the problems discussed in Troubleshooting in this manual to eliminate common problems. 2. If the problem persists, contact APC Customer Support throu...
Page 18 - Smart-UPS Factory Warranty; LIMITED WARRANTY
15 Smart-UPS X-Series Operation Smart-UPS Factory Warranty LIMITED WARRANTY American Power Conversion (APC) warrants its Smart-UPS (Products) to be free from defects in materials and workmanship for a period of three (3) years, excluding the batteries, which are warranted for two (2) years from date...
Page 19 - EC Declaration of Conformity
Harmonized Standards EN60950-1; IEC60950-1; EN62040-1-1; EN55022; EN55024;IEC61000-3-2, 3-3, 4-2, 4-3, 4-4, 4-5, 4-6, 4-11 Applicable Council Directives 2006/95/EC; 2004/108/EC Type of Equipment Uninterruptible Power Supply Model Numbers SMX750I, SMX1000I, SMX1500RMI2U, SMX1500RMI2UNC Manufacturers ...