Page 2 - Contents; PREPARATION; Correct Disposal of This Product
ENGLISH-2 Contents PREPARATION Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Product specifications . . . . . . . . . . ...
Page 3 - ATION; Safety precautions; WARNING; or accessing its internal components .; GENERAL INFORMATION; Do not place containers with liquids or other objects on the unit .
ENGLISH-3 01 PREPAR ATION Safety precautions All materials supplied to this manual are indispensable for the safety of equipment .Users shall establish appropriate safety and health practices and determine the applicability of regulatory limitation based on following descriptions prior to use . WARN...
Page 4 - INSTALLING THE UNIT; Always verify that a suitable grounding connection is available .
ENGLISH-4 Safety precautions INSTALLING THE UNIT IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines . Always disassemble the electric lines before the refrigerant tubes . f f Upon receipt, inspect the product to verify that it has n...
Page 5 - Product specifications; Product compatibility
ENGLISH-5 01 PREPAR ATION Product specifications Product compatibility Indoor unit Outdoor unit Slim Duct MSP Duct RAC Console Tank Integrated Hydro Units 2.2~5.6kW 7.1~9kW 2.2~7.1kW 2.2~5.6kW 200~260L Classification Features AE022MNLDEHAE028MNLDEHAE036MNLDEHAE056MNLDEH AE071MNMPEH AE090MNMPEH AE022...
Page 6 - Accessories
ENGLISH-6 Product specifications Accessories Installation Manual (2) Zone sensor (1x10m, WH) (2) Temperature Sensor for Mixing Valve (1x15m, BLU) (1) Sensor holder of zone sensor and mixing valve (3) Sensor clip of zone sensor and mixing valve (3) Cable-tie for zone sensor and mixing valve (6) Alumi...
Page 7 - Specifications; Model Name
ENGLISH-7 01 PREPAR ATION Specifications Model Name AE200TNWTEH AE260TNWTEH Power source V/Hz 1Φ, 220-240V~, 50Hz 1Φ, 220-240V~, 50Hz Operation Range [Water] Cooling °C 5~25 5~25 Heating °C 15~55 15~55 Sound Pressure Cooling dB(A) 26 26 Heating dB(A) 26 26 Sound Power Heating dB(A) 40 40 Dimension (...
Page 8 - Subsidiary materials compatibility; the ceiling or outdoor area .
ENGLISH-8 Product specifications Subsidiary materials compatibility Indoor unit Subsidiary materials Slim Duct MSP Duct RAC Console Tank Integrated Hydro Units Remark 2.2~5.6kW 7.1~9kW 2.2~7.1kW 2.2~5.6kW 200~260L EEV Kit EEV Kit for 1/2/3 room - - MEV-E24SAMEV-E32SA MXD-E24K132AMXD-E24K200AMXD-E24K...
Page 9 - Typical application examples; ensure that the return water temperature not exceed 55 °C .; The below examples are for illustration purposes only .; Application 1: Space heating + water heating
ENGLISH-9 01 PREPAR ATION Typical application examples • The application examples given below are for illustration purposes only .• When the SAMSUNG Air-to-Water Heat Pump system is used in series with another heat source (e .g . gas boiler), ensure that the return water temperature not exceed 55 °C...
Page 11 - Main components; Part name
ENGLISH-11 01 PREPAR ATION Main components ① ② ③ ④ ⑤ ⑥ ⑦⑨ ⑩ ⑪ ㉑ ⑮ ㉓ ㉕ ㉖ ⑧ ⑲ ⑱ ⑳ ⑰ ⑯ ⑭ ㉒ ㉔㉗ ㉘ ㉙ ㉚ ㉛ ㉜ ㉝ ⑬ ⑫ ㉞ No. Part name Note ① Refrigerant pipe ø15 .88 (5/8"), Flare nut ② Refrigerant pipe ø9 .52 (3/8"), Flare nut ③ Hot water outlet ø22, Straight pipe ④ Secondary return ø22, Straight pipe...
Page 13 - Functional diagram
ENGLISH-13 01 PREPAR ATION Functional diagram 3 G3 KIT 3-Way V/V Backup heater(2kW) PWM Pump HX_PHE Expansion Vessel(8L) Flow sensor Pressure Relief v/v Air Vent Manometer Water in Water out Temperature & pressure relief valve Drain(Tundish) T_tank T_w3 T_w2 T_w1 Heating T_eva out T_eva in Boost...
Page 14 - Dimensional drawing; Split
ENGLISH-14 Dimensional drawing ①② ③ ④ ⑤⑥⑦ 595 700 85 85 85 85 70 70 1844 42 No Split Size type ① Refrigertant (Gas) Ø15 .88 Flare nut ② Refrigertant (Liquid) Ø9 .52 Flare nut ③ Hot water outlet Ø22, T1 .0 Straight pipe ④ Secondary return (260L option) Ø22, T1 .0 Straight pipe ⑤ Cold water inlet Ø22,...
Page 15 - Installing the unit; Installation of the indoor unit
ENGLISH-15 02 INSTALLATION Installing the unit Installation of the indoor unit The indoor unit should be installed indoors and meet the following conditions . f f Installation site should be sheltered from frost . f f In area with suitable space for servicing . f f A place with adequate ventilation ...
Page 16 - Moving the Indoor unit with a fork lift
ENGLISH-16 Installing the unit Moving the Indoor unit with a fork lift f f Insert the fork into the wooden pallet at the bottom of the indoor unit carefully . Be careful that the fork does not damage the indoor unit . f f When moving the Indoor unit, be care the damage of indoor unit by impact . Do ...
Page 17 - Base construction and installation of the Tank hydro unit
ENGLISH-17 02 INSTALLATION Base construction and installation of the Tank hydro unit Manufacturer is not responsible for the damage occurred by not following the installation standards .1 . Considering the vibration and weight of the Tank hydro unit, strength of the base ground must be strong enough...
Page 18 - Drain Work; Produced defrost water must be drained through the drain hole .
ENGLISH-18 Installing the unit Drain Work f f In the cooling operation, defrost water may be produced from the pipes or tank . f f Produced defrost water must be drained through the drain hole . f f When the drain plug is used, make sure that it is located at a height of 100 mm or more from the floo...
Page 19 - Pipe work; Refrigerant pipe work; piping connections can be damaged .
ENGLISH-19 02 INSTALLATION Pipe work Refrigerant pipe work For all guide lines, specifications regarding refrigerant pipe work between the indoor unit and the outdoor unit, please follow the outdoor unit installation manual . Gas pipe (O .D .) Liquid pipe (O .D .) Indoor unit 15 .88 mm (5/8 inch) 9 ...
Page 20 - Water pipe work; Allowable water pressure of hydro unit is maximum 3 .0 bar .
ENGLISH-20 Pipe work Water pipe work The hydro unit is equipped with components listed on the table below .The hot and cold water supply connections are clearly marked on the unit with labels . And service valves are provided .Whole water plumbing system including Hydro unit shall be installed by a ...
Page 21 - Flushing and air-purging
ENGLISH-21 02 INSTALLATION Flushing and air-purging When filling water, the following start-up procedure should be followed . 1 . All system components and pipes must be tested for the presence of leaks .2 . Make-up water assembly or Flushing unit is recommended for installation and service .3 . Bef...
Page 23 - PWM characteristic curve
ENGLISH-23 02 INSTALLATION PWM characteristic curve PWM input signal(%) Max . Speed The additional pump should be the same type of product as the above graph .RecommendationGRUNDFOS UPMM 25-95 (Heating Type) Case 2) AC pump The maximum number of additional pump installation is one AC pumps (Input po...
Page 24 - Setting the pre-pressure of the expansion vessel; Use only dry nitrogen to set the expansion vessel pre-pressure .; Installation height; Calculating the pre-pressure of the expansion vessel
ENGLISH-24 Pipe work Setting the pre-pressure of the expansion vessel When it is required to change the default pre-pressure of the expansion vessel(1 bar), keep in mind the following guidelines: f f Use only dry nitrogen to set the expansion vessel pre-pressure . f f Inappropriate setting of the ex...
Page 25 - Charging water; Connect water lines to water connections of hydro unit .; Pressure relief valve; Piping insulation
ENGLISH-25 02 INSTALLATION Charging water Liquid Pipe Gas Pipe Cap Water Inlet Air-vent valve Water Outlet DHW Inlet Recirculation Inlet (Only 260 Liter Model) DHW Outlet After installation is completed the following procedures shall be used to charge water into the hydro unit . f f Connect water li...
Page 26 - Wiring work; Incomplete earth may cause electrical problems .; Layout of PCB
ENGLISH-26 Wiring work • Field-supplied electrical components such as power switch, circuit breakers, wires, terminal blocks, etc must be properly chosen with compliance with national legislation or regulation . • Switch off the power supply before making any connections .• All field wiring and comp...
Page 33 - Selecting solderless ring terminal
ENGLISH-33 02 INSTALLATION Selecting solderless ring terminal f f Select a solderless ring terminal of a connecting power cable based on a nominal dimensions for cable . f f Cover a solderless ring terminal and a connector part of the power cable and then connect it . Nominal dimensions for cable (m...
Page 34 - Torque requirements; Screw size
ENGLISH-34 Wiring work Torque requirements CONTROL-KIT PBA M3 M3 M3.5 M3.5 M4 Screw size Tightening torque (N·m) Part Terminal code Remarks M3 0 .5~0 .75 Control Kit PBA 2P Terminal Block PV/Peak power control SIGNAL Dry contact input R-32 ALARM Dry contact output WATER PUMP PWM signal output M3 .5 ...
Page 36 - Types of allowable current; Minimum cross-sectional area of conductors; the appliance and the entry to the plug .; Grounding work; Grounding must be done by a qualified installer for your safety .; Grounding the power cable; Ground the power cable according to the following .; Note 1) Grounding work 3
ENGLISH-36 Wiring work Types of allowable current Conductors of supply cord shall have a nominal cross-sectional area not less than that shown in the table below . Minimum cross-sectional area of conductors Rated current of appliance (A) Nominal cross-sectional area (mm2) ≤0 .2 Tinsel cord a) ≤0 .2 ...
Page 37 - Checking correct grounding; . Connect the flexible hose to the flexible hose port .; Secure the grounding wire in position with staples .
ENGLISH-37 02 INSTALLATION Checking correct grounding If the power distribution circuit does not have a grounding or the grounding does not comply with specifications, an grounding electrode must be installed . The corresponding accessories are not supplied with the Air to Water Heat pump .1 . Selec...
Page 38 - Connection of the power supply and communication cable; Model
ENGLISH-38 Wiring work Connection of the power supply and communication cable Model Description No. of wires Max. A Thickness Supply Scope Inlet hole positions for power/ communication wires AE***TNWTEH 1 Phase main power 2 + ground 22 .7A 4 .0mm2 ↑ H05RN-F or H07RN-F Field supply (220- 240Vac, Inpu...
Page 39 - manufacturer or installer .
ENGLISH-39 02 INSTALLATION 2 wires for communication cable TB-A TB-C TB-A1 1 2 1 2 F4 F3 V2 V1 F2 F1 CONTROL-KIT PBA Earth Communication cable between indoor and outdoor units Communication cable Hydro unit Circuit breaker Communication cable connection TB-A TB-C TB-A1 1 2 1 2 F4 F3 V2 V1 F2 F1 CONT...
Page 40 - Connecting the power terminal; Use certified and reliable cables .; Connection of the backup heater power supply; heater and booster heater has the dedicated power supply .
ENGLISH-40 Wiring work ❋ ❋ ELCB : Earth leakage circuit breakerELB : Earth leakage breakerMCCB : Molded case circuit breaker Connecting the power terminal f f Connect the cables to the terminal board using the solderless ring terminal . f f Use certified and reliable cables . f f Connect the cables ...
Page 41 - Connection of the thermostat; Description; block as shown on the diagram .
ENGLISH-41 02 INSTALLATION 1 phase Booster heater (DHW, assembly in factory) 1 Phase ELCB DHW Tank Connection of the thermostat Description No. of wires Max. current Thickness Supply Scope Room Thermostat 4 22mA > 0 .75 mm 2 , H05RN-F or H07RH-F Field supply (220-240V~, Input) N L C1 H1 N L C2 H2...
Page 42 - Connection of the 2-way valve; -way motorized valve
ENGLISH-42 Wiring work Connection of the 2-way valve Description No. of wires Min. / Max. current Thickness Supply Scope Motorized 2-way valve to shut off UFH loops during cooling . 2+ground 10mA / 50mA > 0 .75 mm 2 , H05RN-F or H07RH-F Field supply (220- 240V~, Output) N L1 N L2 * Connection of ...
Page 45 - Connection of the 3-way valve; -way diverting valve for water tank
ENGLISH-45 02 INSTALLATION Connection of the 3-way valve Description No. of wires Mini. / Max. current Thickness Supply Scope Diverting type 3way valve 4 10mA / 50mA > 0 .75 mm 2 , H05RN-F or H07RN-F Field supply (220-240V~, Input) B17 : 3WAY (L1) B18 : 3WAY (L2) B16 : Live (L) B15 : Neutral (N) ...
Page 46 - Connection of the back-up boiler; Connecting for external contact functions; Connecting external sensors for zone control
ENGLISH-46 Wiring work Connection of the back-up boiler Description No. of wires Mini. / Max. current Thickness Supply Scope Back-up Boiler 2+ground 10mA / 50mA 0 .75mm 2 H05RN-F or H07RN-F Field supply (220-240V~, Input) L N L N When it set back up boiler on the hydro unit (relay off ) Boiler B4 : ...
Page 47 - Connecting for smart grid ready control; SG READY Signal 1
ENGLISH-47 02 INSTALLATION Connecting for smart grid ready control 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Connection terminal for SG READY Signal 1 Connection terminal for SG READY Signal 2 SG READY Signal 2 SG READY Signal 1 SG READY Signal 1 SG READY Signal 2 Product operation Short Op...
Page 48 - Self-test mode of wired remote controller; Use of self-test mode; and
ENGLISH-48 Self-test mode of wired remote controller Use of self-test mode 0 Please enter your PASSWORD Service mode Service mode Reset All Service Mode Power Master Reset ODU K3 Reset Field Setting Value Self-Test Mode Indoor Unit Option 1 . If you want to use the various additional functions for y...
Page 49 - THERS; Troubleshooting; Thermistor; Check its location as shown at the diagram .; OTHERS
ENGLISH-49 03 O THERS Troubleshooting If the unit has some problem to work properly, the LED on hydro unit will flash and some error codes will be displayed on the controller .The following table described the explanation of error codes on the LCD display . Thermistor f f Check its resistance . 10ko...
Page 50 - Communication; Display
ENGLISH-50 Troubleshooting Communication Display Explanation Communication error between remote controller and the Hydro unit Tracking error between remote controller and the Hydro unit Memory(EEPROM) Read/Write Error(Wired remote controller data error) E601, E604 E654 MEMORY(EEPROM) Read/Write Erro...
Page 51 - Water pump & Flow Sensor; Water flow range; Min
ENGLISH-51 03 O THERS Water pump & Flow Sensor Display Explanation Low flow rate error• in case of low flow rate in 30 sec during water pump signals is ON(Starting)• in case of low flow rate in 15 sec during water pump signals is ON(After starting)Normal flow rate error• in case of normal flow r...
Page 52 - DHW tank; Piping diagram; direction and in a frost-free environment .
ENGLISH-52 DHW tank Piping diagram • The product must be installed without any water leakage .• Please verify that the DHW tank and other components are properly installed and reinstall them if necessary . - Use certified components and the correct tools . - Keep adequate space for the installing . ...
Page 53 - Note; System configuration
ENGLISH-53 03 O THERS No. Note No. Note ① Service valve ⑦ T-Joint ② 3 way diverting valve ⑧ Expansion relief Valve ③ Drain Valve ⑨ T-Joint ④ T-Joint ⑩ Pressure reducing valve with integrated check valve and strainer ⑤ Tundish Tank Temp Temperature sensor for DHW tank ⑥ Expansion vessel ❋ ❋ The table...
Page 54 - Switch box layout; booster heater may operate depending on the settings .
ENGLISH-54 DHW tank Switch box layout DHW Tank Temp . CNS042(YEL) • When you set the hot water supply temperature to 55°C or less, do not use the booster heater . - The heatpump and the booster heater operate until the initial set temperature is reached . After that, only the booster heater may oper...
Page 55 - Electrical connections; Procedure; Connections to be made in the electrical box of DHW tank
ENGLISH-55 03 O THERS Electrical connections Procedure • Switch off the power supply before making any connections .• Use a thermal grease in thermistor pocket after installing electric connections . WARNING Connections to be made in the electrical box of DHW tank 1 . Connect the booster heater powe...
Page 56 - Problem; screw is properly fitted .
ENGLISH-56 DHW tank Troubleshooting IMPORTANT: All maintenance or repair work must be executed by an approved installer . Problem Possible cause Solution Hot water is not coming out . No power supply to the water heater Check if there is any power on the power supply terminal on the thermostat . The...
Page 57 - Mixing Valve; Installation of mixing valve
ENGLISH-57 03 O THERS Mixing Valve Installation of mixing valve Under Floor Radiator TW4 Balancing Vessel (Mixing tank) When two different zones are used with different temperature, adjust the temperature of discharge water to high temperature water and control the amount of bypass to provide low te...
Page 58 - The mixing valve is controlled based on the FCU WL value .; -zone control using Thermostat
ENGLISH-58 Mixing Valve ❋ ❋ The mixing valve is controlled based on the FCU WL value . ❋ ❋ As the #4044 value increases and the #4045 value decreases, the control speed increases . (Temperature hunting may occur if the control speed increases depending on the load .) ❋ ❋ The additional pump and mixi...
Page 59 - -Zone Control Using Remote Controller
ENGLISH-59 03 O THERS 2-Zone Control Using Remote Controller 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Tw2_z2 M Tw2_z1 Zone2 19/20 17/18 B14/B15 B10/B11 B2/B3/B5 Radiator Zone1 Under Floor Balancing Vessel Mixing Senser(Default, 15 m) CNS045(BLU) You can operate the 2-zone control using a m...
Page 60 - Temperature sensor work; Example of sensor installation; When the pipe is a copper pipe
ENGLISH-60 Temperature sensor work Example of sensor installation Weld the sensor holder on the selected location of the pipe and then insulate it . When the pipe is a copper pipe When the pipe is not a copper pipe Pipe Sensor holder Pipe Sensor Sensor clip Sensor Aluminum tape Sensor Rubber tape Se...
Page 61 - Setting the EHS converter
ENGLISH-61 03 O THERS Setting the EHS converter Mode Selection switch Micro SD card Left position: Field Setting Value (FSV) mode Right position: Operating Data Backup mode Left position Right position f f Micro SD card is a separate purchase, using 8 ~ 32GB It's possible .
Page 62 - Reading and writing FSV; How to upload or download field settings (example); . Insert an SD card into the Sub PBA SD Card slot on the Hydro unit .
ENGLISH-62 Temperature sensor work Reading and writing FSV How to upload or download field settings (example) 1 . Insert an SD card into the Sub PBA SD Card slot on the Hydro unit . Micro SD card 2 . Select Field Setting Value in Service mode .3 . Press Up/Down button to select FSV Upload or Downloa...
Page 63 - How to download to a microSD card
ENGLISH-63 03 O THERS How to download to a microSD card 1 . Download the wired remote controller image, change the file name to “IMAGE .BIN,” and then download to microSD Card .2 . Download the wired remote controller program, change the file name to “MICOM .BIN,” and then download to microSD Card ....
Page 64 - When the microSD Card is removed during download; and the download is stopped .
ENGLISH-64 Temperature sensor work When the microSD Card is removed during download 1 . When you remove the microSD Card during download, the “INSERT MICROSD CARD AND SYSTEM RESET” screen appears and the download is stopped . 2 . When you insert the microSD Card and press the and buttons for system ...
Page 65 - Concrete curing function; Entering procedure; If an error is displayed, concrete curing function does not work .
ENGLISH-65 03 O THERS Concrete curing function When pipes of floor heating are installed, operation for reinforcing concrete curing is applied . (Period of operation: 23 days) Entering procedure 1 . After turning off the DIP switch K3 of indoor unit (Default ON), power off and on the indoor unit . T...
Page 66 - Micom; DIP switch
ENGLISH-66 Concrete curing function NOTE • Definition of Dip switch function Dip S/W S/W #1 S/W #2 S/W #3 S/W #4 ON (default) • None • None • None • Turn off when an E101 error occurs OFF • Emergency heating • Emergency hot water supply • Concrete curing • E101 error does not turn off reference item...
Page 67 - Installation option setting; The procedure of option setting; Entering mode for option
ENGLISH-67 03 O THERS Installation option setting f f Set the indoor unit installation option with remote controller option . The procedure of option setting High Temp Button High Fan Button Mode change Low Temp Button Low Fan Button Entering mode for option setting Option setting mode Entering mode...
Page 68 - Changing a particular option; You can change each digit of set option .
ENGLISH-68 Installation option setting Changing a particular option You can change each digit of set option . Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 Explanation PAGE MODE The option mode you want to change The tens’ digit of an option SEG you will change The unit digit of an option SEG you will change...
Page 69 - Optional : Extending the power cable
ENGLISH-69 03 O THERS Optional : Extending the power cable 1 . Prepare the following tools . Tools Spec Shape Crimping pliers MH-14 Connection sleeve (mm) 20xØ6 .5 (HxOD) Insulation tape Width 19 mm Contraction tube (mm) 70xØ8 .0 (LxOD) 2 . As shown in the figure, peel off the shields from the rubbe...
Page 70 - Incomplete wire connections can cause electric shock or a fire .
ENGLISH-70 • After compressing it, pull both sides of the wire to make sure it is firmly pressed . Compress it 4 times 5 mm Method 1 Method 2 Compress it 4 times 5 mm 5 . Wrap it with the insulation tape twice or more and position your contraction tube in the middle of the insulation tape . 40 mm In...
Page 71 - Model code Outdoor
ENGLISH-71 03 O THERS Reference (HP KEYMARK Certification) Model code Outdoor Model code Indoor Registration number AE044MXTPEH/EU AE200TNWTEH/EU 011-1W0369 AE066MXTPEH/EU AE200TNWTEH/EU AE044MXTPEH/EU AE260TNWTEH/EU 011-1W0370 AE066MXTPEH/EU AE260TNWTEH/EU AE090MXTPEH/EU AE200TNWTEH/EU 011-1W0372 A...