Samsung AE200TNWTEH/EU - Installation Manual

Samsung AE200TNWTEH/EU

Samsung AE200TNWTEH/EU Air Conditioner – Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
Page: / 72

Table of Contents:

  • Page 2 – Contents; PREPARATION; Correct Disposal of This Product
  • Page 3 – ATION; Safety precautions; WARNING; or accessing its internal components .; GENERAL INFORMATION; Do not place containers with liquids or other objects on the unit .
  • Page 4 – INSTALLING THE UNIT; Always verify that a suitable grounding connection is available .
  • Page 5 – Product specifications; Product compatibility
  • Page 6 – Accessories
  • Page 7 – Specifications; Model Name
  • Page 8 – Subsidiary materials compatibility; the ceiling or outdoor area .
  • Page 9 – Typical application examples; ensure that the return water temperature not exceed 55 °C .; The below examples are for illustration purposes only .; Application 1: Space heating + water heating
  • Page 11 – Main components; Part name
  • Page 13 – Functional diagram
  • Page 14 – Dimensional drawing; Split
  • Page 15 – Installing the unit; Installation of the indoor unit
  • Page 16 – Moving the Indoor unit with a fork lift
  • Page 17 – Base construction and installation of the Tank hydro unit
  • Page 18 – Drain Work; Produced defrost water must be drained through the drain hole .
  • Page 19 – Pipe work; Refrigerant pipe work; piping connections can be damaged .
  • Page 20 – Water pipe work; Allowable water pressure of hydro unit is maximum 3 .0 bar .
  • Page 21 – Flushing and air-purging
  • Page 23 – PWM characteristic curve
  • Page 24 – Setting the pre-pressure of the expansion vessel; Use only dry nitrogen to set the expansion vessel pre-pressure .; Installation height; Calculating the pre-pressure of the expansion vessel
  • Page 25 – Charging water; Connect water lines to water connections of hydro unit .; Pressure relief valve; Piping insulation
  • Page 26 – Wiring work; Incomplete earth may cause electrical problems .; Layout of PCB
  • Page 33 – Selecting solderless ring terminal
  • Page 34 – Torque requirements; Screw size
  • Page 36 – Types of allowable current; Minimum cross-sectional area of conductors; the appliance and the entry to the plug .; Grounding work; Grounding must be done by a qualified installer for your safety .; Grounding the power cable; Ground the power cable according to the following .; Note 1) Grounding work 3
  • Page 37 – Checking correct grounding; . Connect the flexible hose to the flexible hose port .; Secure the grounding wire in position with staples .
  • Page 38 – Connection of the power supply and communication cable; Model
  • Page 39 – manufacturer or installer .
  • Page 40 – Connecting the power terminal; Use certified and reliable cables .; Connection of the backup heater power supply; heater and booster heater has the dedicated power supply .
  • Page 41 – Connection of the thermostat; Description; block as shown on the diagram .
  • Page 42 – Connection of the 2-way valve; -way motorized valve
  • Page 45 – Connection of the 3-way valve; -way diverting valve for water tank
  • Page 46 – Connection of the back-up boiler; Connecting for external contact functions; Connecting external sensors for zone control
  • Page 47 – Connecting for smart grid ready control; SG READY Signal 1
  • Page 48 – Self-test mode of wired remote controller; Use of self-test mode; and
  • Page 49 – THERS; Troubleshooting; Thermistor; Check its location as shown at the diagram .; OTHERS
  • Page 50 – Communication; Display
  • Page 51 – Water pump & Flow Sensor; Water flow range; Min
  • Page 52 – DHW tank; Piping diagram; direction and in a frost-free environment .
  • Page 53 – Note; System configuration
  • Page 54 – Switch box layout; booster heater may operate depending on the settings .
  • Page 55 – Electrical connections; Procedure; Connections to be made in the electrical box of DHW tank
  • Page 56 – Problem; screw is properly fitted .
  • Page 57 – Mixing Valve; Installation of mixing valve
  • Page 58 – The mixing valve is controlled based on the FCU WL value .; -zone control using Thermostat
  • Page 59 – -Zone Control Using Remote Controller
  • Page 60 – Temperature sensor work; Example of sensor installation; When the pipe is a copper pipe
  • Page 61 – Setting the EHS converter
  • Page 62 – Reading and writing FSV; How to upload or download field settings (example); . Insert an SD card into the Sub PBA SD Card slot on the Hydro unit .
  • Page 63 – How to download to a microSD card
  • Page 64 – When the microSD Card is removed during download; and the download is stopped .
  • Page 65 – Concrete curing function; Entering procedure; If an error is displayed, concrete curing function does not work .
  • Page 66 – Micom; DIP switch
  • Page 67 – Installation option setting; The procedure of option setting; Entering mode for option
  • Page 68 – Changing a particular option; You can change each digit of set option .
  • Page 69 – Optional : Extending the power cable
  • Page 70 – Incomplete wire connections can cause electric shock or a fire .
  • Page 71 – Model code Outdoor
Loading the manual

Air to Water Heat Pump

Installation manual

TDM PLUS Tank Integrated Hydro Unit AE***TNWTEH

• Thank you for purchasing this Samsung Product.

• Before operating this unit, please read this installation manual carefully and retain it for future

reference.

DB68-08915A-04

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Samsung AE200TNWTEH/EU

Summary

Page 2 - Contents; PREPARATION; Correct Disposal of This Product

ENGLISH-2 Contents PREPARATION Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Product specifications . . . . . . . . . . ...

Page 3 - ATION; Safety precautions; WARNING; or accessing its internal components .; GENERAL INFORMATION; Do not place containers with liquids or other objects on the unit .

ENGLISH-3 01 PREPAR ATION Safety precautions All materials supplied to this manual are indispensable for the safety of equipment .Users shall establish appropriate safety and health practices and determine the applicability of regulatory limitation based on following descriptions prior to use . WARN...

Page 4 - INSTALLING THE UNIT; Always verify that a suitable grounding connection is available .

ENGLISH-4 Safety precautions INSTALLING THE UNIT IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines . Always disassemble the electric lines before the refrigerant tubes . f f Upon receipt, inspect the product to verify that it has n...